48V 200Ah rack mount LiFePO4 telecom lithium battery
48V Lithium Telecom Batteries

Rack Mount 48V 200Ah LiFePO4 Telecom Battery

The long hold-up module in the telecom range: 48V 200Ah, 10 kWh, in a modular design that fits a 19-inch server rack and parallels for larger banks.

48V 200Ah rack mount LiFePO4 telecom lithium battery

Product Overview

The long hold-up module in the telecom range: 48V 200Ah, 10 kWh, in a modular design that fits a 19-inch server rack and parallels for larger banks. It is specified for communication systems that cannot afford a short outage - access network infrastructure, mobile communication units, remote exchange stations, satellite ground stations, transmission systems and microwave networks. Rated 6000+ cycles with a five-year warranty, and samples are available for testing before a rollout.

Key benefits

Why Buyers Choose This Pack

10 kWh Per Rack Module

Longer hold-up from one module means fewer units in the cabinet and fewer interconnects to maintain.

Parallels To 40 kWh

Two units give 20 kWh, three give 30 and four give 40, so a site grows without changing its power architecture.

Built For The 19-Inch Cabinet

Modular design for the racks the network already uses, rather than a bespoke enclosure per site.

Sample Before Rollout

Samples are available for testing, which is how a network operator should qualify any backup product.

Application scenarios

Where It Is Used

  • Base stations requiring extended hold-up
  • Remote exchange stations and access network cabinets
  • Satellite ground stations and microwave links
  • Transmission systems and repeater sites
  • Data centre and comms room 48V DC plant
  • Solar-hybrid telecom sites with unreliable grid supply
Who it is for

The Buyers This Pack Suits

Network Operators And Tower Companies

Sites where hold-up time is measured in hours and a truck roll is expensive.

Telecom Integrators

Specifying backup across a mixed estate of cabinets and site types.

Distributors Serving Infrastructure

Carrying a long-duration module alongside the 50Ah and 100Ah sizes.

Problems it solves

What It Fixes

Short Hold-Up On Long Outages

Where grid interruptions run for hours, a 2.4 or 4.8 kWh module is not the right tool. 10 kWh per module is.

Cabinet Congestion

Fewer, larger modules free rack units for transmission equipment.

Qualification Before Rollout

Sample availability means the first deployment is not the test.

Specifications

Published Figures For This Pack

Every value below comes from our own product specification. Where a figure is not published we leave it out rather than estimating it.

Rack Mount 48V 200Ah LiFePO4 Telecom Battery specification
Nominal voltage48 V
Capacity200 Ah / 10 kWh
Format19-inch rack module
Cycle life6000+ cycles
Parallel expansion2 units 20 kWh, 3 units 30 kWh, 4 units 40 kWh
SampleAvailable for testing
Warranty5 years
OEM / ODMYes
CertificatesCE, UL, MSDS, IEC, UN38.3, ISO
Cells and BMSGrade A LiFePO4 cells, smart BMS
Packing and documents

How It Ships And What Comes With It

Packing And Shipping

Packing follows UN38.3 requirements for lithium battery transport, and the carton and pallet arrangement is confirmed with the quotation for your quantity and destination. We do not publish a fixed carton specification here because it changes with order size and freight mode.

Documentation

UN38.3 and the MSDS travel with every lithium shipment, and the certificates listed in the specification table above are supplied for the model you order. Tell us the destination market at the quotation stage so the document set is planned rather than chased after the goods are built. Where a certificate we do not hold is required, we will say so rather than promise it.

Manufacturing

This pack is built at Shenzhen Sike Power Technology Co., Ltd. in Da Peng New District, Shenzhen, with cell grading, assembly, BMS integration, aging test and final inspection carried out in house. Only brand-new grade A LiFePO4 cells and a top-brand smart BMS go into it.

Download the catalogue and datasheets for the specification in PDF form.

Installation guide

Getting It Right First Time

Step 1

Calculate the requirement as site load in kW times the hold-up hours, then add headroom for ageing and load growth.

Step 2

Confirm the rectifier charge profile and communication - RS485 or CAN - before installation day.

Step 3

Check the cabinet depth and rail rating against the module before ordering.

Step 4

Specify cold-climate protection if the cabinet is unheated and charging can occur below freezing.

Step 5

Run a pilot site with a sample before committing to an estate-wide rollout.

Comparison

How It Compares In Our Range

The 48V telecom range is three capacities on one architecture; the site load and hold-up target pick the module.

Alternatives to the Rack Mount 48V 200Ah LiFePO4 Telecom Battery
48V 50Ah2.4 kWh, small cabinets and short hold-up
48V 100Ah4.8 kWh, standard base station backup
48V 200Ah10 kWh, long hold-up or high site load
51.2V 200Ah rack moduleSame capacity class for solar and UPS rather than DC plant
FAQ

Rack Mount 48V 200Ah LiFePO4 Telecom Battery Questions

How much hold-up will 10 kWh give me?

Divide 10 kWh by the site load in kW and allow for conversion losses. A 1.5 kW site gets roughly five to six usable hours from one module. Send the real load and we will size it properly.

Can I parallel several modules?

Yes - the published expansion is 2 units for 20 kWh, 3 for 30 kWh and 4 for 40 kWh.

Will it work with my existing rectifier?

Usually after a change to a LiFePO4 charge profile and the communication setup. Send the rectifier model and we will confirm before you order.

Are samples available?

Yes, samples are available for testing, which is the right way to qualify a backup product before a rollout.

What is the warranty?

Five years, against a published 6000+ cycle rating.

Which certificates does it carry?

CE, UL, MSDS, IEC, UN38.3 and ISO are listed for this product.

Applications

Sectors That Use This Pack

Telecom And Data Centre Backup

48V rack packs at 50Ah, 100Ah and 200Ah for base stations, exchanges and DC plant, 6000+ cycles, parallel to fifteen units.

Commercial And Industrial Energy Storage

Liquid-cooled 215 kWh and 232 kWh all-in-one cabinets, plus 51.2V modular banks for smaller commercial sites.

Further reading

Guides That Cover This Pack

Calculating Hold-Up Time For A 48V Telecom Site

Turning site load in kW into a module count, and the four things that make the real hold-up shorter than the arithmetic.

Reading A Lithium Battery Specification Without Being Misled

Which figures on a battery datasheet are meaningful, which are marketing, and the six questions that expose a thin specification.

Quote The Rack Mount 48V 200Ah LiFePO4 Telecom Battery

Send the quantity, the application and the destination, and we will confirm specification, packing and lead time.