All-In-One 215 kWh Commercial Industrial ESS
A 215 kWh commercial and industrial storage cabinet at 768V nominal, built on the same all-in-one liquid-cooled architecture as the 232 kWh unit: LFP battery, smart BMS, liquid-cooled PCS, EMS, thermal control, power distribution and fire protection integrated in one enclosure.

Product Overview
A 215 kWh commercial and industrial storage cabinet at 768V nominal, built on the same all-in-one liquid-cooled architecture as the 232 kWh unit: LFP battery, smart BMS, liquid-cooled PCS, EMS, thermal control, power distribution and fire protection integrated in one enclosure. It is the size chosen where the site's demand profile and PCS rating point to 768V, and like its larger sibling it parallels for greater capacity.

Why Buyers Choose This Pack
768V Bus For A Matched PCS
Where the project's power conversion design favours 768V, this is the cabinet that fits it without adaptation.
Integrated Fire Protection
The fire system is part of the product rather than a separate package bolted on during installation.
Liquid-Cooled Consistency
Temperature spread inside the pack held below 2.5 degrees Celsius, credited with 30% longer life and 20% lower energy consumption.
Modular Installation
Designed to be installed and expanded in modules rather than as a single site-built system.
Where It Is Used
- Demand charge reduction for factories and logistics sites
- Commercial building tariff arbitrage
- Industrial solar self-consumption
- Campus microgrids and backup
- Renewable capacity firming
- EV charging infrastructure support
The Buyers This Pack Suits
C&I Project Developers
Sizing storage against a specific tariff or demand-charge case.
EPC And Integration Contractors
Wanting a tested integrated cabinet rather than multi-vendor assembly.
Facility Operators
Where outage cost, not tariff, drives the investment.
What It Fixes
Matching Battery To PCS
Bus voltage is a real design constraint. Two cabinet options at 768V and 832V give the project a fit.
Site Commissioning Complexity
An integrated product cuts the number of interfaces that have to be proven on site.
Fire And Code Compliance
Integrated protection plus destructive test verification is the starting point; local code still governs siting.
Published Figures For This Pack
Every value below comes from our own product specification. Where a figure is not published we leave it out rather than estimating it.
| Capacity | 215 kWh |
|---|---|
| Nominal voltage | 768 V |
| Architecture | All-in-one: LFP battery, smart BMS, liquid-cooled PCS, EMS, thermal control, power distribution, fire protection |
| Thermal management | Smart liquid cooling, cell temperature difference inside the pack below 2.5 degrees Celsius |
| Claimed effect of cooling | Life increased by 30%, energy consumption reduced by 20% |
| Safety testing | Verified by destructive tests including short circuit, burning and fire resistance |
| Expansion | Parallel more units for higher capacity |
| Installation | All-in-one design, modular installation |
| Cells and BMS | LFP battery with integrated PCS, EMS and fire protection |
How It Ships And What Comes With It
Packing And Shipping
Packing follows UN38.3 requirements for lithium battery transport, and the carton and pallet arrangement is confirmed with the quotation for your quantity and destination. We do not publish a fixed carton specification here because it changes with order size and freight mode.
Documentation
UN38.3 and the MSDS travel with every lithium shipment, and the certificates listed in the specification table above are supplied for the model you order. Tell us the destination market at the quotation stage so the document set is planned rather than chased after the goods are built. Where a certificate we do not hold is required, we will say so rather than promise it.
Manufacturing
This pack is built at Shenzhen Sike Power Technology Co., Ltd. in Da Peng New District, Shenzhen, with cell grading, assembly, BMS integration, aging test and final inspection carried out in house. Only brand-new grade A LiFePO4 cells and a top-brand smart BMS go into it.
Download the catalogue and datasheets for the specification in PDF form.
Getting It Right First Time
Step 1
Share interval consumption data and the demand-charge structure so capacity is derived rather than assumed.
Step 2
Confirm the PCS rating and the bus voltage the project requires before choosing between the two cabinets.
Step 3
Raise fire, siting and clearance requirements with the local authority early.
Step 4
Agree the specification, documentation and commissioning support in writing.
Step 5
Plan physical space for additional cabinets if load growth is expected.
How It Compares In Our Range
The two cabinets differ in capacity and bus voltage; everything else is shared.
| 215 kWh cabinet | 768 V nominal, all-in-one liquid cooled |
|---|---|
| 232 kWh cabinet | 832 V nominal, same architecture |
| 51.2V rack bank | Smaller commercial sites built from 5 and 10 kWh modules |
| 30 kWh floor unit | Light commercial and large residential |
All-In-One 215 kWh Commercial Industrial ESS Questions
215 kWh or 232 kWh?
It follows the bus voltage and capacity your PCS design and load profile call for: 768V at 215 kWh, or 832V at 232 kWh.
Is the PCS included?
Yes - along with the EMS, liquid-cooling thermal control, power distribution and fire protection.
Can capacity be added later?
Yes, by paralleling further units. Plan the physical space and the electrical provision at the first install.
What about fire safety approval?
Fire protection is integrated and the design cites destructive test verification. Local code still governs siting and clearance, so involve the authority early.
Do you support commissioning?
Technical support through commissioning is standard. On-site attendance depends on the project and destination - raise it during quotation.
What is the lead time?
It depends on capacity, configuration and market certification. Send the project details and you will get a build and shipping schedule.
Sectors That Use This Pack
Commercial And Industrial Energy Storage
Liquid-cooled 215 kWh and 232 kWh all-in-one cabinets, plus 51.2V modular banks for smaller commercial sites.
Telecom And Data Centre Backup
48V rack packs at 50Ah, 100Ah and 200Ah for base stations, exchanges and DC plant, 6000+ cycles, parallel to fifteen units.
Guides That Cover This Pack
Reading A Lithium Battery Specification Without Being Misled
Which figures on a battery datasheet are meaningful, which are marketing, and the six questions that expose a thin specification.
Calculating Hold-Up Time For A 48V Telecom Site
Turning site load in kW into a module count, and the four things that make the real hold-up shorter than the arithmetic.