48V Lithium Telecom Batteries
48V server rack packs at 50Ah, 100Ah and 200Ah for base stations, exchanges and data centres, 6000+ cycles, 19-inch format.

Four packs built for the 48V DC plant that runs telecom: 2.4 kWh and 4.8 kWh slim modules at 482x480x132 mm, and a 10 kWh 200Ah module for sites that need a longer hold-up. All of them are grade A LiFePO4 with a smart BMS, all fit a 19-inch rack, and all are specified at 6000+ cycles because a backup battery that has to be replaced every three years costs more in truck rolls than it does in hardware.
All 4 Products In This Group
What This Group Is Built To Solve
A VRLA string in a base station cabinet is a maintenance programme disguised as a battery: it loses capacity quietly, it fails at the moment the grid does, and nobody finds out until the site drops. Lithium changes the failure mode. The BMS reports state of charge and cell balance continuously, the pack holds its capacity across thousands of cycles, and a 48V module weighs a fraction of the string it replaces, which matters when the cabinet is at the top of a tower access road.
Who This Range Is For
Telecom Operators And Tower Companies
Replacing VRLA in base stations, remote exchanges and microwave sites.
Data Centre And Comms Room Engineers
Backing up 48V DC plant where rack space and weight are both constrained.
System Integrators And Distributors
Specifying backup for access networks, satellite ground stations and transmission systems.
What Makes This Range Different
The 48V DC Plant Format
19-inch modules at 482x480x132 mm on the 50Ah and 100Ah packs, sized for the cabinets the network already uses.
Three Capacities, One Bus
2.4 kWh, 4.8 kWh and 10 kWh so hold-up time is a module count rather than a redesign.
Parallel Expansion To Fifteen Units
The published telecom range parallels up to fifteen modules, which is how a site grows without changing its power architecture.
Monitoring That Prevents Truck Rolls
Smart BMS reporting with optional Bluetooth on the 100Ah pack, so cell drift shows up as data instead of a site outage.
Where These Packs Are Used
- Base station and tower site backup
- Remote exchanges and access network cabinets
- Data centre and comms room 48V DC plant
- Satellite ground stations and microwave links
- Solar-hybrid telecom sites in areas with unreliable grid
- UPS duty for security, monitoring and control systems
Sectors That Specify This Group
Telecom And Data Centre Backup
48V rack packs at 50Ah, 100Ah and 200Ah for base stations, exchanges and DC plant, 6000+ cycles, parallel to fifteen units.
Commercial And Industrial Energy Storage
Liquid-cooled 215 kWh and 232 kWh all-in-one cabinets, plus 51.2V modular banks for smaller commercial sites.
Guides Related To This Group
Calculating Hold-Up Time For A 48V Telecom Site
Turning site load in kW into a module count, and the four things that make the real hold-up shorter than the arithmetic.
Reading A Lithium Battery Specification Without Being Misled
Which figures on a battery datasheet are meaningful, which are marketing, and the six questions that expose a thin specification.
48V Lithium Telecom Batteries Questions
Do these drop into an existing 48V VRLA cabinet?
Mechanically, in most cases - the 50Ah and 100Ah modules are 482x480x132 mm for a 19-inch rack. Electrically, check the rectifier's charge profile and communication; a lithium pack wants a LiFePO4 charge curve and will report over RS485 or CAN rather than sitting passive on the bus.
How long will a 48V 100Ah pack hold a site?
That is load arithmetic: 4.8 kWh divided by the site load in kW, less inverter and conversion losses. Send us the site load and the hold-up hours you need and we will tell you the module count rather than guessing at it.
What IP rating do the telecom packs have?
IP20 on the 50Ah and 100Ah rack modules, which is an indoor cabinet rating. For outdoor enclosures, the cabinet provides the protection - tell us the enclosure and we will confirm suitability.
Can they run in parallel with the existing lead-acid string?
Not recommended. Lead-acid and lithium have different charge voltages and internal resistance, so the lithium pack takes the load and the lead-acid string sits float-charged and ages. Replace the string rather than mixing chemistries.
Is heating available for cold-climate sites?
Optional heating and Bluetooth are published on the 48V 100Ah pack. Specify it at enquiry if the cabinet drops below freezing while charging.
What certificates come with them?
CE, UL, MSDS, IEC, UN38.3 and ISO are listed across the telecom range. UN38.3 and the MSDS are the ones your freight forwarder will ask for.
Get A Quotation On 48V Lithium Telecom Batteries
Send the models, the quantities and the destination and we will confirm specification, packing and lead time.