CIP System
A CIP system handling 1000 L/H to 30,000 L/H in SUS304, for cleaning dairy, fruit juice and beverage production lines after each run.

Product Overview
A CIP system handling 1000 L/H to 30,000 L/H in SUS304, for cleaning dairy, fruit juice and beverage production lines after each run. The standard sequence is acid cleaning, alkali cleaning, hot water cleaning and pure cold water cleaning, and the procedure can be designed to your production requirements. Full-auto, semi-auto and manual control are available. Standard components include a full-auto SIEMENS PLC control system and touch screen, UK Spirax Sarco steam pressure reducing and drain system, a German temperature inspection and regulation system, a German JUMO conductivity meter and German Contrinex or IFM flow rate switches.
Why Buyers Choose This Specification
Conductivity Meter Fitted as Standard
A JUMO conductivity meter is what distinguishes chemical from rinse water in the return line. Without it, recovery CIP is guesswork and rinse water ends up in the chemical tank.
Four-Stage Sequence, Configurable
Acid, alkali, hot water and pure cold water stages, with the procedure designed to your production requirements rather than fixed.
Flow Switches on the Circuit
Contrinex or IFM flow rate switches confirm the circuit is actually flowing. A CIP cycle that runs without flow cleans nothing and reports success.
Three Automation Levels
Full-auto, semi-auto and manual, so the capital cost matches the size and staffing of the plant.
Where It Is Used
- Cleaning tanks and lines after a production run
- Product changeover cleaning on a shared line
- Daily hygiene cycles in a dairy plant
- Cleaning a fruit juice processing line
- Multi-circuit CIP across a beverage plant
- Recovery CIP reducing chemical consumption
The Buyers This Product Suits
Dairy Plants
Dairy lines are cleaned every day, and an automated CIP set is what makes that consistent rather than operator-dependent.
Juice and Beverage Producers
Both are named applications, and product changeover cleaning is what governs how many products a line can run.
Plants Under Hygiene Audit
PLC control with conductivity and flow monitoring produces the cleaning record an auditor asks for.
What It Fixes
Cleaning Results That Vary by Operator
Full-auto PLC control runs the same sequence at the same temperatures and concentrations every time.
Chemical Lost to Drain
A conductivity meter allows chemical to be separated from rinse water and recovered.
A Cycle That Runs Without Flow
Flow rate switches confirm circulation before the cycle is counted as complete.
Published Figures For This Product
Every value below comes from our own product specification. Where a figure is not published we leave it out rather than estimating it.
| Product Model | HTK-QX-01 |
|---|---|
| Working Capacity | 1000 L/H to 30,000 L/H, customised |
| Material | SUS304 |
| Cleaning Sequence | Acid, alkali, hot water, pure cold water |
| Control | Full-auto, semi-auto, manual |
| PLC | Full-auto SIEMENS PLC control system and touch screen |
| Steam System | UK Spirax Sarco steam pressure reducing and drain system |
| Temperature | German temperature inspection and regulation system |
| Conductivity | German JUMO conductivity meter |
| Flow Switch | German Contrinex or IFM |
| Minimum Order | One unit |
| Production Capacity | 50 units per month |
| Grade | SUS304 |
How It Ships And What Comes With It
Packing And Loading
Shipping volume for this item depends on the configuration and capacity you select, so no fixed container figure is published. Confirm the specification and the destination and a loading plan is issued with the quotation, rather than a figure we cannot support.
Documentation On File
- Dairy and Liquid Processing · Dairy Processing Machinery Specification Sheet53.2 KB
- Catalogue · Full Product Catalogue154.0 KB
Sourcing And Inspection
This product is supplied through TrueGlow Imaging, working with manufacturing partners whose facilities are visited and verified rather than taken on trust. In-process quality control and delivery supervision are available so goods are inspected before the container is sealed. Certifications quoted on this page are those stated on the product specification and belong to that product range rather than to our trading entity, so ask for the certificate covering your specific item.
Getting It Right First Time
Step 1
Map every circuit in the plant and its required flow before sizing the CIP set.
Step 2
Design the sequence to your products rather than accepting a default.
Step 3
Set conductivity thresholds so chemical and rinse water separate reliably.
Step 4
Verify return flow on each circuit, since it is what limits cleaning coverage.
Step 5
Record each cycle and keep the traces for audit.
How It Compares In Our Range
Three control levels for the same cleaning sequence.
| Full-Auto | SIEMENS PLC controlled, runs the full sequence and records it. Consistent and auditable. |
|---|---|
| Semi-Auto | Operator initiates each stage with automatic control within it. |
| Manual | Lowest capital cost, suited to small plants with few circuits. |
CIP System Questions
What capacity is available?
1000 L/H to 30,000 L/H, customised.
What is the cleaning sequence?
Acid cleaning, alkali cleaning, hot water cleaning and pure cold water cleaning, with the procedure designed to your production requirements.
What control options are available?
Full-auto, semi-auto and manual.
What instrumentation is fitted?
German JUMO conductivity meter, German Contrinex or IFM flow rate switches, and a German temperature inspection and regulation system.
What material is it built from?
SUS304.
What is the minimum order?
One unit, with a production capacity of 50 units per month.
Sectors That Use This Product
Dairy Processing
From the milking parlour to the sealed pack, with the cleaning system that keeps it legal.
Brewing and Beverage
Fermentation, bright tank, pasteurisation and filling for beer water and soft drinks.
Food Packaging Lines
Depalletizing to palletizing, balanced against the filler in the middle.
Guides That Cover This Product
Pasteurisation Versus UHT for Liquid Dairy
Three thermal profiles, three different machines and three different distribution models. Which one your plant needs is decided by shelf life and cold chain, not by capacity.
Specifying a CIP System That Actually Cleans
A cleaning cycle that runs without flow cleans nothing and reports success. Conductivity monitoring, flow switches and return pump selection are what make CIP verifiable.
Quote CIP System
Send the capacity or size you need, the quantity and the destination, and we will confirm the configuration, the lead time and a loading plan.