CIP System supplied by TrueGlow Imaging
Dairy Processing Machinery

CIP System

A CIP system handling 1000 L/H to 30,000 L/H in SUS304, for cleaning dairy, fruit juice and beverage production lines after each run.

CIP System supplied by TrueGlow Imaging

Product Overview

A CIP system handling 1000 L/H to 30,000 L/H in SUS304, for cleaning dairy, fruit juice and beverage production lines after each run. The standard sequence is acid cleaning, alkali cleaning, hot water cleaning and pure cold water cleaning, and the procedure can be designed to your production requirements. Full-auto, semi-auto and manual control are available. Standard components include a full-auto SIEMENS PLC control system and touch screen, UK Spirax Sarco steam pressure reducing and drain system, a German temperature inspection and regulation system, a German JUMO conductivity meter and German Contrinex or IFM flow rate switches.

Key benefits

Why Buyers Choose This Specification

Conductivity Meter Fitted as Standard

A JUMO conductivity meter is what distinguishes chemical from rinse water in the return line. Without it, recovery CIP is guesswork and rinse water ends up in the chemical tank.

Four-Stage Sequence, Configurable

Acid, alkali, hot water and pure cold water stages, with the procedure designed to your production requirements rather than fixed.

Flow Switches on the Circuit

Contrinex or IFM flow rate switches confirm the circuit is actually flowing. A CIP cycle that runs without flow cleans nothing and reports success.

Three Automation Levels

Full-auto, semi-auto and manual, so the capital cost matches the size and staffing of the plant.

Application scenarios

Where It Is Used

  • Cleaning tanks and lines after a production run
  • Product changeover cleaning on a shared line
  • Daily hygiene cycles in a dairy plant
  • Cleaning a fruit juice processing line
  • Multi-circuit CIP across a beverage plant
  • Recovery CIP reducing chemical consumption
Who it is for

The Buyers This Product Suits

Dairy Plants

Dairy lines are cleaned every day, and an automated CIP set is what makes that consistent rather than operator-dependent.

Juice and Beverage Producers

Both are named applications, and product changeover cleaning is what governs how many products a line can run.

Plants Under Hygiene Audit

PLC control with conductivity and flow monitoring produces the cleaning record an auditor asks for.

Problems it solves

What It Fixes

Cleaning Results That Vary by Operator

Full-auto PLC control runs the same sequence at the same temperatures and concentrations every time.

Chemical Lost to Drain

A conductivity meter allows chemical to be separated from rinse water and recovered.

A Cycle That Runs Without Flow

Flow rate switches confirm circulation before the cycle is counted as complete.

Specifications

Published Figures For This Product

Every value below comes from our own product specification. Where a figure is not published we leave it out rather than estimating it.

CIP System specification
Product ModelHTK-QX-01
Working Capacity1000 L/H to 30,000 L/H, customised
MaterialSUS304
Cleaning SequenceAcid, alkali, hot water, pure cold water
ControlFull-auto, semi-auto, manual
PLCFull-auto SIEMENS PLC control system and touch screen
Steam SystemUK Spirax Sarco steam pressure reducing and drain system
TemperatureGerman temperature inspection and regulation system
ConductivityGerman JUMO conductivity meter
Flow SwitchGerman Contrinex or IFM
Minimum OrderOne unit
Production Capacity50 units per month
GradeSUS304
Packing and documents

How It Ships And What Comes With It

Packing And Loading

Shipping volume for this item depends on the configuration and capacity you select, so no fixed container figure is published. Confirm the specification and the destination and a loading plan is issued with the quotation, rather than a figure we cannot support.

Documentation On File

Sourcing And Inspection

This product is supplied through TrueGlow Imaging, working with manufacturing partners whose facilities are visited and verified rather than taken on trust. In-process quality control and delivery supervision are available so goods are inspected before the container is sealed. Certifications quoted on this page are those stated on the product specification and belong to that product range rather than to our trading entity, so ask for the certificate covering your specific item.

Handling guide

Getting It Right First Time

Step 1

Map every circuit in the plant and its required flow before sizing the CIP set.

Step 2

Design the sequence to your products rather than accepting a default.

Step 3

Set conductivity thresholds so chemical and rinse water separate reliably.

Step 4

Verify return flow on each circuit, since it is what limits cleaning coverage.

Step 5

Record each cycle and keep the traces for audit.

Comparison

How It Compares In Our Range

Three control levels for the same cleaning sequence.

Alternatives to CIP System
Full-AutoSIEMENS PLC controlled, runs the full sequence and records it. Consistent and auditable.
Semi-AutoOperator initiates each stage with automatic control within it.
ManualLowest capital cost, suited to small plants with few circuits.
FAQ

CIP System Questions

What capacity is available?

1000 L/H to 30,000 L/H, customised.

What is the cleaning sequence?

Acid cleaning, alkali cleaning, hot water cleaning and pure cold water cleaning, with the procedure designed to your production requirements.

What control options are available?

Full-auto, semi-auto and manual.

What instrumentation is fitted?

German JUMO conductivity meter, German Contrinex or IFM flow rate switches, and a German temperature inspection and regulation system.

What material is it built from?

SUS304.

What is the minimum order?

One unit, with a production capacity of 50 units per month.

Industries

Sectors That Use This Product

Dairy Processing

From the milking parlour to the sealed pack, with the cleaning system that keeps it legal.

Brewing and Beverage

Fermentation, bright tank, pasteurisation and filling for beer water and soft drinks.

Food Packaging Lines

Depalletizing to palletizing, balanced against the filler in the middle.

Further reading

Guides That Cover This Product

Pasteurisation Versus UHT for Liquid Dairy

Three thermal profiles, three different machines and three different distribution models. Which one your plant needs is decided by shelf life and cold chain, not by capacity.

Specifying a CIP System That Actually Cleans

A cleaning cycle that runs without flow cleans nothing and reports success. Conductivity monitoring, flow switches and return pump selection are what make CIP verifiable.

Quote CIP System

Send the capacity or size you need, the quantity and the destination, and we will confirm the configuration, the lead time and a loading plan.