
Large Outdoor Milk Storage Silo
A large outdoor milk storage silo from 15,000 L to 120,000 L in SUS304 or SUS316L, built as a three layer tank with insulation and jacket.

Product Overview
A large outdoor milk storage silo from 15,000 L to 120,000 L in SUS304 or SUS316L, built as a three layer tank with insulation and jacket. The inner shell is 3 to 4 mm, the outer cladding 2 mm and the cooling jacket 1.5 mm. It is supplied with product inlet and outlet, manway, side agitator, PT100 thermometer, air ventilation cap, aseptic sample valve, CIP cleaning ball, cooling inlet and outlet and level instrumentation.
Why Buyers Choose This Specification
Plate Thicknesses Published
Inner shell 3-4 mm, outer cladding 2 mm, cooling jacket 1.5 mm. Silo quotations rarely state these, and they are what the price difference between suppliers actually comes from.
Built to Stand Outdoors
Three layer construction with insulation and cladding is what lets a silo hold milk temperature outside, which frees the building for process equipment.
Aseptic Sample Valve Fitted
Milk in bulk storage has to be sampled without contaminating the silo. The valve is standard rather than an extra.
Side Agitator as Standard
A side agitator keeps fat from separating during long holding periods, which is what keeps the silo contents homogeneous for the next process step.
Where It Is Used
- Bulk raw milk storage at a large dairy plant
- Outdoor silo storage freeing indoor floor space
- Buffer storage between milk intake and processing
- Storing other liquid food products in bulk
- Holding milk between tanker deliveries and processing runs
- Large dairy factories requiring 120,000 L capacity
The Buyers This Product Suits
Large Dairy Factories
The silo is used in big milk production factories where storage volume exceeds what can sensibly sit indoors.
Plants Short of Building Space
Outdoor silos move bulk storage out of the process hall entirely.
Processors of Other Bulk Liquids
The silo can also store other liquid food products where the same construction suits them.
What It Fixes
Bulk Storage Consuming Factory Floor
An insulated outdoor silo holds the volume without taking building space.
Temperature Loss in Outdoor Storage
Three layer construction with insulation and a 1.5 mm cooling jacket is what maintains milk temperature outdoors.
Sampling Without Contaminating the Silo
An aseptic sample valve is fitted as a standard component.
Published Figures For This Product
Every value below comes from our own product specification. Where a figure is not published we leave it out rather than estimating it.
| Product Model | HTK-NC-01 |
|---|---|
| Product Volume | 15,000 L to 120,000 L, customised |
| Material | SUS304 / SUS316L |
| Inner Shell | 3-4 mm |
| Outer Cladding | 2 mm |
| Cooling Jacket | 1.5 mm |
| Structure | Three layer tank with insulation and jacket |
| Agitation | Side agitator |
| Instrumentation | PT100 thermometer, level sensors |
| Sampling | Aseptic sample valve |
| Cleaning | CIP cleaning ball |
| Minimum Order | One unit |
| Production Capacity | 50 units per month |
| Grade | SUS304 / SUS316L |
How It Ships And What Comes With It
Packing And Loading
Shipping volume for this item depends on the configuration and capacity you select, so no fixed container figure is published. Confirm the specification and the destination and a loading plan is issued with the quotation, rather than a figure we cannot support.
Documentation On File
- Dairy and Liquid Processing · Dairy Processing Machinery Specification Sheet53.2 KB
- Catalogue · Full Product Catalogue154.0 KB
Sourcing And Inspection
This product is supplied through TrueGlow Imaging, working with manufacturing partners whose facilities are visited and verified rather than taken on trust. In-process quality control and delivery supervision are available so goods are inspected before the container is sealed. Certifications quoted on this page are those stated on the product specification and belong to that product range rather than to our trading entity, so ask for the certificate covering your specific item.
Getting It Right First Time
Step 1
Size the silo against tanker delivery volume and processing draw-down rate.
Step 2
Confirm foundation design for a full silo at your chosen volume.
Step 3
Specify SUS316L where water chloride levels justify it.
Step 4
Connect the CIP cleaning ball into the plant CIP circuit at installation.
Step 5
Verify agitator run times so milk is homogeneous without being sheared.
How It Compares In Our Range
Outdoor silo against indoor storage tanks.
| Large Outdoor Milk Storage Silo | 15,000 to 120,000 L, three layer with insulation and jacket, sited outdoors on its own foundation. |
|---|---|
| Stainless Steel Storage Tank | 500 L to 100,000 L for indoor installation, with insulation and jacketing specified as required. |
Large Outdoor Milk Storage Silo Questions
What volumes are available?
15,000 L to 120,000 L, customised.
What are the plate thicknesses?
Inner shell 3-4 mm, outer cladding 2 mm, cooling jacket 1.5 mm.
What is the structure?
A three layer tank with insulation and jacket.
What components are included?
Product inlet and outlet, manway, side agitator, PT100 thermometer, air ventilation cap, aseptic sample valve, CIP cleaning ball, cooling inlet and outlet and level instrumentation.
Can it store products other than milk?
Yes, it can also be used for other liquid food products.
What is the minimum order?
One unit, with a production capacity of 50 units per month.
Sectors That Use This Product
Dairy Processing
From the milking parlour to the sealed pack, with the cleaning system that keeps it legal.
Brewing and Beverage
Fermentation, bright tank, pasteurisation and filling for beer water and soft drinks.
Food Packaging Lines
Depalletizing to palletizing, balanced against the filler in the middle.
Guides That Cover This Product
Pasteurisation Versus UHT for Liquid Dairy
Three thermal profiles, three different machines and three different distribution models. Which one your plant needs is decided by shelf life and cold chain, not by capacity.
Specifying a CIP System That Actually Cleans
A cleaning cycle that runs without flow cleans nothing and reports success. Conductivity monitoring, flow switches and return pump selection are what make CIP verifiable.
Quote Large Outdoor Milk Storage Silo
Send the capacity or size you need, the quantity and the destination, and we will confirm the configuration, the lead time and a loading plan.


