S1(n)-35 Halogen Free Busbar Insulation Heat Shrink Tube 6 to 36 kV

The 36 kV halogen free busbar grade for switchgear where clearance is tight and smoke toxicity is regulated

  • Operating temperature: -40 to 105°C
  • Minimum full recovery temperature: 125°C
  • Voltage class: 6kV to 36kV
  • Halogen-free, RoHS compliant
  • Shrink ratio: 2:1 & 2.5:1
  • Standard Color: Red
S1(n)-35 Halogen Free Busbar Insulation Heat Shrink Tube 6 to 36 kV manufactured by UPM Heat Shrink

S1(n)-35  ·  Busbar Insulation and Covers

Product Overview

What S1(n)-35 Does

Halogen-free and environmentally friendly polyolefin material, can be applied in 6kV to 36kV power switchgear, providing insulation enhancement, protection against flashover or accidental discharge. Especially suitable for switchgear with limited space, it can be used for circular and rectangular copper or aluminum busbars.

The 36 kV halogen free busbar grade for switchgear where clearance is tight and smoke toxicity is regulated It is manufactured by Dalian United Polymer Material Co., Ltd. in Dalian China where radiation cross linking extrusion and molding are all performed in house under one quality system.

Key Benefits

  • Insulation enhancement rated for the full 6 to 36 kV range
  • Halogen free and RoHS compliant for critical and occupied buildings
  • Suits round and rectangular copper and aluminium bar
  • 2:1 and 2.5:1 ratios for a wide bar section range
  • Especially suited to switchgear where internal space is limited

Who It Is For

Who Benefits Most from S1(n)-35

The buyers and site teams this product was designed around

36 kV Switchgear Manufacturers

At 36 kV internal clearances dominate cubicle size and insulated busbar is what makes a compact design possible.

Renewable Substation Builders

Collector substations at 33 or 35 kV built to a small footprint.

Data Centre and Critical Facility Operators

36 kV incomers where halogen free is a building requirement.

Industrial Plant Electrical Departments

35 kV distribution switchgear inside process buildings.

Problems It Solves

Problems This Product Removes

Every one of these is a failure mode we have seen on real networks

36 kV Air Clearance Requirements Make Cubicles Large

Insulating the busbar raises withstand so the physical design can stay compact.

Higher Voltage Means Less Tolerance for Pollution

A dust film on bare 36 kV bar is a genuine flashover risk. An insulated surface is far more tolerant.

Animal Ingress Faults Are Catastrophic at 36 kV

Insulated bar removes the bridging path entirely.

Halogen Release Inside a Building Is Unacceptable

The halogen free formulation is required in occupied and critical facilities.

Application Scenarios

Where It Is Used

36 kV Switchgear Main Busbar

Insulating the main bar in a compact 36 kV cubicle.

Collector Substation Switchgear

33 and 35 kV renewable collector switchboards.

Transformer to Switchgear Bar

Insulating the connection bar in a tight cable box.

Generator Connection Bars

Insulating bar between generator and MV switchgear.

Switchgear Refurbishment

Reinsulating during a 36 kV switchboard overhaul.

Technical Data

Specifications and Dimensions

Test methods and requirements taken directly from the manufacturing specification

Technical Data

PropertyTest MethodRequirement
Specific gravityASTM D26711.0-1.2
Thermal enduranceIEC 216105°C minimum
Tensile StrengthASTM D2671≥14 MPa
Ultimate ElongationASTM D2671≥400%
Heat Aging (136°C/168h) Tensile Strength Ultimate ElongationASTM D2671≥12 MPa ≥300%
Long-term Heat Aging (100°C/3000h) Ultimate ElongationIEC 60684-2≥175%
Fluid resistance (23°C/168h) Tensile Strength Ultimate ElongationIEC 60684-2≥8 MPa ≥250%
Water absorption (23°C/24h)ASTM D2671≤1.0%
Low-temperature flexibility (-40°C/4h)ASTM D2671No cracking
Heat shock (200°C/4h)ASTM D2671No cracking, dripping or flowing
Dielectric strengthASTM D2671≥16 kV/mm
Volume resistivityASTM D2671≥1.0×1013Ω·cm
Tracking and erosion resistanceASTM D2303After 1hr at 2.5kV, and 1hr at 2.75kV, No burn penetration, no sustained burning
Color fastness to lightIEC 60684-3-283Color stability, no change
Copper corrosion (150°C/168h)IEC 60684-3-283No corrosion

Dimensions

Size S1(n)-35As supplied (mm) Inner diameter D (min.)After recovered (mm) Inner diameter d (max.)Wall thickness t (nom.)Standard length (m)
25/1025103.515
30/1230123.615
40/1640163.615
50/2050203.615
65/2565253.615
75/3075303.715
85/3585353.715
100/40100403.715
120/50120503.815
150/60150603.815
175/75175753.815
Products Slection
Bus Bar Size (mm)Single Layer Bus BarDouble Layer Bus Bar
20×3, 25×3Φ25/10Φ30/12
30×3, 30×4Φ30/12Φ40/16
30×10, 40×4Φ40/16Φ50/20
40×10, 50×5, 50×6Φ50/20Φ65/25 (Φ75/30)
50×8, 50×10, 60×6, 60×8Φ65/25 (Φ75/30)Φ75/30(Φ85/35)
60×10, 80×6, 80×8, 80×10Φ75/30(Φ85/35)Φ100/40(Φ120/50)
100×8, 100×10, 100×12Φ100/40(Φ120/50)Φ120/50
150×12, 150×15Φ150/60Φ175/75

CROSS REFERENCE  ·  Tyco-Raychem: BBIT

Manufacturing and Quality

How It Is Made and Checked

Compounding extrusion radiation cross linking expansion and test all under one roof in Dalian

  1. 01

    Compounding

    Base polyolefin antioxidants flame retardants and functional fillers are mixed to a recipe held under our own formulation control rather than bought as a masterbatch.

  2. 02

    Extrusion

    The compound is extruded to the required wall and diameter. Co extruded products form two or three layers in a single pass so no interface can trap air.

  3. 03

    Radiation Cross Linking

    Electron beam irradiation creates the cross linked network that gives the material its shape memory. This step is what makes the product heat shrinkable.

  4. 04

    Expansion

    The cross linked part is heated expanded to its supplied diameter and cooled under tension so the expanded shape is locked in until heat is applied again.

  5. 05

    Test and Inspection

    More than 90 percent of product performance tests are carried out in our own laboratory including tensile elongation heat aging dielectric strength and tracking resistance.

  6. 06

    Packing and Traceability

    Each batch carries a production record so a delivered part can be traced back to its compound lot and process parameters.

Extrusion and irradiation workshop at the UPM Heat Shrink factory in Dalian China
Extrusion and processing workshop in Dalian. Line side inspection stations let an operator check wall thickness and concentricity without stopping the run.

Certification

ISO 9001:2015

Quality management system

IATF 16949:2016

Automotive quality management

ISO 14001:2015

Environmental management

ISO 45001:2018

Occupational health and safety

GJB 9001C-2017

Defence quality management

UL 224 E341796

Extruded insulating tubing

CE / RoHS

European conformity and restricted substances

CCS / ABS / DNV

Marine classification society approvals

Comparison

How S1(n)-35 Compares

An honest comparison so you can rule this product in or out quickly

ProductVoltage ClassFire BehaviourColour Options
S1(n)-106 to 24 kVHalogen freeRed
S1(n)-356 to 36 kVHalogen freeRed
S1-106 to 24 kVFlame retardantRed yellow green blue
S1-356 to 36 kVFlame retardantRed yellow green blue

Use Guide

How to Select and Install S1(n)-35

The sequence our engineers walk customers through on every first installation

  1. 01

    Confirm the Voltage Class

    Use S1(n)-35 from 6 to 36 kV. Below 24 kV S1(n)-10 is the economic choice.

  2. 02

    Measure the Bar Diagonal and Perimeter

    The tube must clear the diagonal and recover onto the perimeter.

  3. 03

    Deburr Every Edge

    Sharp corners cut a recovering tube. Break all edges first.

  4. 04

    Degrease the Bar

    Machining oil and oxide prevent the tube sitting cleanly on the metal.

  5. 05

    Shrink from the Middle

    Work outward to both ends so trapped air escapes.

  6. 06

    Cover Joints with Molded Covers

    Use S1-B lap joint covers on bolted connections.

FAQ

S1(n)-35 Frequently Asked Questions

The questions buyers ask before they place an order

Why is there a separate 36 kV grade
The wall thickness and formulation are matched to the higher voltage class. Fitting a 24 kV grade on a 36 kV bar does not give the required withstand margin.
Is it available in phase colours
The halogen free grade is red as standard. For phase identification in red yellow green and blue use the flame retardant S1-35 grade.
Can it be applied to bar that is already installed
Yes provided the bar can be disconnected at one end so the tube can be slid on. Where that is not possible use S1-A wrap around cover or S1-B molded covers.
Does it work on aluminium bar
Yes. It works on both copper and aluminium and on round or rectangular sections.
What is the low temperature rating
-40 °C. That covers unheated switchrooms and outdoor kiosk substations in cold climates.
Do you supply cut lengths
Yes. Tell us the bar lengths and we will supply pre cut pieces to reduce site waste.