Skip to content

Product Category

Medium and Heavy Wall Tubing

Adhesive lined polyolefin tubing for sealing insulating and mechanically protecting cable up to 36 kV

4 PRODUCTS  ·  MANUFACTURED IN DALIAN CHINA

Medium and Heavy Wall Tubing from UPM Heat Shrink

Who It Is For

Who Buys This Category

Tunnel Metro and Building Services Contractors

Halogen free is mandatory where cable fire smoke would fill an enclosed space.

Marine Offshore and Harbour Contractors

Flame retardant grades formulated for wet salt laden environments.

Direct Buried Cable Contractors

Heavy wall grades that survive backfill abrasion and ground movement.

Mining and Heavy Industry Maintenance

Trailing and feeder cable that takes continuous mechanical abuse.

Problems Solved

Problems This Category Removes

Halogenated Smoke Is a Life Safety Issue in Enclosed Routes

The halogen free grades release no corrosive halide gas and are specified in tunnels metro stations data centres and hospitals.

Marine Environments Destroy Ordinary Tubing

The flame retardant grades are formulated for wet and underground service on vessels platforms shipyards and harbours.

Medium Wall Abrades Through in Buried and Trafficked Positions

The heavy wall grades raise the abrasion and crush allowance substantially at the same shrink ratio.

A 2:1 Tube Will Not Span a Connector Step

3:1 and 4:1 shrink ratios let one stock size cover a wide diameter range.

Application Scenarios

Where This Category Is Used

Cable Joint Outer Protection

Sealing and mechanical protection over a completed LV or MV joint.

Cable Jacket Repair

Covering a damaged outer sheath section on a free cable end.

Bulkhead and Gland Entry Sealing

Sealing where cable passes through a barrier.

Busbar and Connector Insulation

Insulating exposed connections inside enclosures.

Marine and Offshore Cable

Flame retardant grades on vessels platforms and quaysides.

Buried and Duct Installations

Heavy wall grades for direct buried joints.

Why UPM

Why Buy This Category from Us

24 years of heat shrink manufacturing with compounding extrusion irradiation and molding in one plant

  • Four grades that let you specify fire behaviour and wall class independently
  • All grades share the same shrink ratios and installation method so crews train once
  • Halogen free and flame retardant formulations both RoHS compliant
  • CCS ABS and DNV marine approvals across the product range
  • Single wall and adhesive lined dual wall available in every grade

Selection

How to Choose Within This Category

  1. 01

    Fix the Fire Requirement First

    Enclosed public routes normally specify halogen free. Marine and offshore normally specify flame retardant. Check the project specification.

  2. 02

    Assess the Mechanical Exposure

    Buried trafficked and abrasive positions take a heavy wall. Protected positions take a medium wall.

  3. 03

    Measure the Diameter Span

    The tube must clear the largest point and recover onto the smallest. That ratio decides 3:1 or 4:1.

  4. 04

    Decide Whether You Need Adhesive

    Adhesive lined dual wall wherever water must be excluded. Single wall for pure insulation inside a dry enclosure.

  5. 05

    Allow Overlap Onto Sound Material

    At least 25 mm of overlap on undamaged surface at each end.

  6. 06

    Check the Adhesive Bead on Completion

    A continuous bead at both ends confirms the seal on a dual wall product.

FAQ

Medium and Heavy Wall Tubing Frequently Asked Questions

What is the difference between halogen free and flame retardant
Flame retardant means the material resists ignition and self extinguishes. Halogen free means it releases no corrosive hydrogen halide gas when it does burn. Enclosed public routes usually specify halogen free and marine rules usually specify flame retardant.
How do I choose between medium wall and heavy wall
Choose heavy wall where the position is buried trafficked or abrasive. Choose medium wall where the tube is protected. Heavy wall costs more per metre and is stiffer after recovery.
When do I need 4:1 instead of 3:1
When the object being covered has a large step such as a connector on a small cable. A 4:1 ratio covers a wider diameter span from one stock size.
Can these tubes be used as MV insulation
They are for sealing insulating and mechanical protection up to 36 kV. They are not stress control layers or primary MV insulation. Use C102 for stress control and C101 or C105 to C107 for MV insulation builds.
Are marine approvals available
UPM materials hold CCS ABS and DNV approvals. Send us the vessel or platform specification and we will confirm which certificate covers your part number.
What colours can you supply
Black is standard across the family. Other colours are available on a production run for phase identification or customer branding.

Still need an answer ask our engineers on WhatsApp

Talk to Us About Medium and Heavy Wall Tubing

Send your cable data drawing or bill of materials and we will return part numbers pricing and a lead time.