Skip to content

Molded Cable Parts

Y2 Heat Shrink Cable End Caps for Sealing and Storage

Adhesive lined molded caps that seal a cut cable end against water ingress during storage transport and installation

  • Operating temperature: -55 to 105°C
  • Minimum fully recovery temperature: 125°C
  • Adhesive liner
  • Standard Color: Black
  • Inflatable seal optional
  • Equivalent to TE SSC, ESC
Y2 Heat Shrink Cable End Caps for Sealing and Storage manufactured by UPM Heat Shrink

Y2  ·  Molded Cable Parts

Product Overview

What Y2 Does

Cross-linked polyolefin,with or without adhesive liner.Insulation protection and sealing of cable end,cable termination.Suitable for electric power cable,communication cables and other industrial cabling pipeline.

Adhesive lined molded caps that seal a cut cable end against water ingress during storage transport and installation It is manufactured by Dalian United Polymer Material Co., Ltd. in Dalian China where radiation cross linking extrusion and molding are all performed in house under one quality system.

Key Benefits

  • A permanent watertight seal on any cut cable end
  • Adhesive liner that bonds to the outer sheath and the exposed core ends
  • Survives duct pulls storage outdoors and long term drum storage
  • Available with an inflatable seal option for pressure tested cable systems
  • Sized for power cable communication cable and industrial pipeline

Who It Is For

Who Benefits Most from Y2

The buyers and site teams this product was designed around

Cable Manufacturers and Drum Yards

Every cut cable end on a drum has to be sealed before the cable leaves the works or water wicks along the conductor.

Utility Stores and Contractors

Part drums returned to store need the cut end resealed or the remaining length is ruined.

Site Installation Crews

Cable pulled into a duct and left overnight must be capped or the trench water finds the conductor.

Telecom and Industrial Cabling Teams

The same problem exists on communication cable and industrial cabling pipelines.

Problems It Solves

Problems This Product Removes

Every one of these is a failure mode we have seen on real networks

Water Wicks Along a Conductor for Metres

Once moisture enters a cut end it travels along the strands under capillary action and along the insulation interface. The damage is invisible until the cable fails a test.

Tape and Plastic Bags Do Not Survive a Trench

A taped end pulled through a duct is stripped off. A shrunk adhesive lined cap survives the pull.

Drum Ends Get Damaged in Transit

A molded cap protects the physical end of the cable as well as sealing it.

Reject Cable Costs Far More Than a Cap

Sealing a cut end is the cheapest insurance a cable owner can buy.

Application Scenarios

Where It Is Used

Drum End Sealing at the Cable Works

Sealing both ends before a drum is shipped.

Part Drum Resealing

Sealing the cut end when a length is taken off a drum.

Overnight Duct Storage

Sealing a cable pulled into a duct before the joint is made.

Cable End Protection in Transit

Protecting the physical end against crushing and abrasion.

Pipeline and Communication Cable Ends

Sealing non power cabling against moisture.

Technical Data

Specifications and Dimensions

Test methods and requirements taken directly from the manufacturing specification

Technical Data

PropertyTest MethodRequirement
Tensile StrengthASTM D2671≥12 MPa
Ultimate ElongationASTM D2671≥300%
Heat Aging (136°C/168h) Tensile Strength Ultimate ElongationASTM D2671≥10 MPa ≥270%
Water absorption (23°C/24h)ASTM D2671≤0.5%
Low-temperature flexibility (-40°C/4h)ASTM D2671No cracking
Heat shock (200°C/4h)ASTM D2671No dripping or flowing
Dielectric strengthASTM D2671≥15 kV/mm
Volume resistivityASTM D2671≥1.0×1013 Ω·cm
Note: Use standard samples for testing

Dimensions

Size Y2As supplied(mm) Inner diameter H (min.)Length P (nom.)After recovered (mm) Inner diameter Big end (max.)Inner diameter Leg (max.)
12/5124552.5
15/8157582.5
20/8207582.8
25/102585102.8
35/183595182.8
40/184095182.8
55/2555125252.8
75/3075140313.2
100/4097140404.8
120/60120150604.4
140/65140180654
160/95160270954
200/95200270954
Y2 construction and dimension diagram
Y2 as supplied and fully recovered dimensions. D is the supplied inner diameter d is the recovered inner diameter and t is the recovered wall thickness.

CROSS REFERENCE  ·  Tyco-Raychem: SSC/ESC

Manufacturing and Quality

How It Is Made and Checked

Compounding extrusion radiation cross linking expansion and test all under one roof in Dalian

  1. 01

    Compounding

    Base polyolefin antioxidants flame retardants and functional fillers are mixed to a recipe held under our own formulation control rather than bought as a masterbatch.

  2. 02

    Extrusion

    The compound is extruded to the required wall and diameter. Co extruded products form two or three layers in a single pass so no interface can trap air.

  3. 03

    Radiation Cross Linking

    Electron beam irradiation creates the cross linked network that gives the material its shape memory. This step is what makes the product heat shrinkable.

  4. 04

    Expansion

    The cross linked part is heated expanded to its supplied diameter and cooled under tension so the expanded shape is locked in until heat is applied again.

  5. 05

    Test and Inspection

    More than 90 percent of product performance tests are carried out in our own laboratory including tensile elongation heat aging dielectric strength and tracking resistance.

  6. 06

    Packing and Traceability

    Each batch carries a production record so a delivered part can be traced back to its compound lot and process parameters.

Extrusion and irradiation workshop at the UPM Heat Shrink factory in Dalian China
Extrusion and processing workshop in Dalian. Line side inspection stations let an operator check wall thickness and concentricity without stopping the run.

Certification

ISO 9001:2015

Quality management system

IATF 16949:2016

Automotive quality management

ISO 14001:2015

Environmental management

ISO 45001:2018

Occupational health and safety

GJB 9001C-2017

Defence quality management

UL 224 E341796

Extruded insulating tubing

CE / RoHS

European conformity and restricted substances

CCS / ABS / DNV

Marine classification society approvals

Comparison

How Y2 Compares

An honest comparison so you can rule this product in or out quickly

MethodDuct Pull SurvivalWater TightnessReusable
Y2 heat shrink end capYesFull sealNo
Tape wrapUsually strippedPartialNo
Plastic bag and tapeNoPoorNo
Mechanical capYesDepends on gasketYes

Use Guide

How to Select and Install Y2

The sequence our engineers walk customers through on every first installation

  1. 01

    Measure over the Cable Sheath

    Choose a cap whose supplied inner diameter clears the cable and whose recovered diameter is smaller than the sheath.

  2. 02

    Cut the Cable End Square

    A square cut lets the cap sit fully home and gives the adhesive a clean face to bond to.

  3. 03

    Clean and Abrade the Sheath

    Wipe the last 100 mm of sheath and lightly abrade it so the adhesive keys to the surface.

  4. 04

    Push the Cap Fully Home

    The cable end should touch the inside of the cap dome.

  5. 05

    Heat from the Dome Backward

    Start at the closed end and work back along the cap so air is expelled at the open end.

  6. 06

    Confirm the Adhesive Bead

    A continuous ring of adhesive at the open end confirms the seal is complete.

FAQ

Y2 Frequently Asked Questions

The questions buyers ask before they place an order

How long will the seal last in storage
A correctly fitted adhesive lined cap seals for the storage life of the cable including outdoor drum storage. Inspect after any mechanical damage.
What is the inflatable seal option
An inflatable version is available for cable systems that are pressure tested or nitrogen filled. Tell us the application and we will confirm the correct part.
Can I use Y2 on communication cable
Yes. Y2 is used on electric power cable communication cable and other industrial cabling pipelines. The selection is based on the outer diameter not the cable type.
Is it removable
No. A shrunk adhesive lined cap is cut off when the cable is used. That is by design because a removable cap will eventually be left loose.
Is Y2 equivalent to Raychem SSC and ESC
It is designed as a functional equivalent. Check the size range against your approved design before substituting.
What sizes are available
The dimension table below lists the full range. Send us the cable outer diameter and we will confirm the part number.

Still need an answer ask our engineers on WhatsApp

Get a Quotation for Y2

Send us the voltage class conductor size and quantity and we will return a part number a price and a lead time. No form to fill in.