Complete termination and joint kits from 0.6/1 kV to 26/35 kV supplied as one part number

3 PRODUCTS  ·  MANUFACTURED IN DALIAN CHINA

Heat Shrink Cable Accessory Kits from UPM Heat Shrink

Who It Is For

Who Buys This Category

Distribution Utilities

Network operators who need an accessory family approved against IEC 60502-4 and GB/T 12706.4 for their whole voltage range.

EPC and Installation Contractors

Project teams buying one accessory family across a substation feeder or collector system.

Industrial Plant Maintenance

Sites that hold their own MV spares and joint their own cable during planned shutdowns.

Renewable Energy Developers

Solar and wind projects making hundreds of identical terminations in a compressed schedule.

Problems Solved

Problems This Category Removes

Loose Components Mean Missing Parts on Site

A kit contains every consumable for one termination or joint with a pack list so nothing is discovered missing in a trench.

Resin Joints Will Not Cure in Cold or Wet Conditions

Heat shrink kits are energisable as soon as they cool regardless of ambient temperature.

Approval Evidence Is Demanded Before a Utility Will Accept an Accessory

C15 and C35 are designed against the full IEC 60502-4 termination and joint test sequences.

Crews Have to Relearn a Method for Every Product

All three kit families share the same installation logic so a jointer qualified on one is competent across the range.

Application Scenarios

Where This Category Is Used

Ring Main Unit and Switchgear Terminations

Indoor terminations into cable boxes at 15 kV and 35 kV class.

Overhead to Underground Transitions

Outdoor pole terminations with rain sheds for creepage.

Duct and Manhole Joints

Straight through joints tested for 30 cycles under 1 m of water.

LV Distribution Boards and Street Cabinets

1 kV terminations on 2 to 6 core cable.

Renewable Collector Circuits

Repeated terminations at collector switching stations.

Industrial Plant Feeders

MV distribution inside steel plants mines and process facilities.

Why UPM

Why Buy This Category from Us

24 years of heat shrink manufacturing with compounding extrusion irradiation and molding in one plant

  • Kits are packed to a bill of materials we control rather than assembled from bought in parts
  • The electrical layers inside the kit are our own compounds extruded and irradiated in our own plant
  • Full IEC 60502-4 and GB/T 12706.4 test evidence available for utility approval submissions
  • Private label packing instruction sheets and carton printing available
  • Standard configurations ship in 5 to 10 working days from Dalian

Selection

How to Choose Within This Category

  1. 01

    Fix the Voltage Class

    0.6/1 kV takes C1. 8.7/15 (17.5) kV takes C15. 26/35 (40.5) kV takes C35. Match the cable U0 rating not the nominal system voltage.

  2. 02

    Decide Termination or Joint

    Terminations start NSY indoor or WSY outdoor. Joints start JSY.

  3. 03

    Count the Cores

    C1 covers 1 to 6 cores. C15 and C35 cover 1 and 3 core cable.

  4. 04

    Read the Conductor Band

    Bands are printed in the selection table on each product page. The last digit of the part number encodes the band.

  5. 05

    Confirm the Environment

    Outdoor terminations in polluted coastal or dusty sites need extra Y3 rain sheds. Tell us the site and we will increase the count.

  6. 06

    Send Us the Data to Confirm

    Message the cable datasheet on WhatsApp and we will verify the part number before you order.

FAQ

Cable Accessory Kits Frequently Asked Questions

Which kit do I need for an 11 kV three core 240 mm² cable termination
An 11 kV cable is normally rated 6.35/11 kV which sits inside the 8.7/15 (17.5) kV class so you need C15. 240 mm² sits in the 150 to 240 mm² band and three core indoor is NSY-1033. The outdoor version is WSY-1033 and the joint is JSY-1033.
Are lugs and connectors included in the kit
The standard kit contains tubing boots mastic and cleaning materials. Lugs and connectors are optional because most utilities specify their own brand and barrel length. Tell us your preference when you enquire.
Can you supply kits printed with our own brand
Yes. We print customer branding on the carton the instruction sheet and the individual component bags. Minimum quantity and lead time depend on the configuration.
What test evidence can you provide
For C15 and C35 we can supply test reports covering AC and DC withstand partial discharge impulse heating cycles immersion thermal and dynamic short circuit humidity and salt fog against IEC 60502-4 and GB/T 12706.4.
How should kits be stored
Sealed in the original carton between 5 and 35 °C away from direct sunlight. Shelf life in these conditions is 5 years.
Do you provide installation training
Every kit carries an illustrated instruction sheet. We can also run a live installation walkthrough over WhatsApp video with your crew before the first joint.

Still need an answer ask our engineers on WhatsApp

Talk to Us About Cable Accessory Kits

Send your cable data drawing or bill of materials and we will return part numbers pricing and a lead time.