Project Case · Marine and Offshore
Deck Cable Protection Package for an Offshore Platform
Heavy wall flame retardant protection where salt spray and mechanical abuse both apply
Client Background
An operator was refurbishing deck and module cabling on an offshore platform. Existing cable protection had degraded under a combination of salt spray UV and mechanical contact with steel structure.
Project Challenge
Specify a single protection material for positions that are simultaneously wet salt laden and mechanically abusive, with classification society approval for the survey file.
Customer Pain Points
- Two requirements that most products satisfy only one of at a time
- Classification society approval needed before the surveyor would accept the material
- Cable dragged over steel structure during installation losing its jacket before commissioning
- Deck work windows dictated by weather not by programme
Our Solution
S3(h) heavy wall flame retardant tubing for the free end positions and R1 wraparound sleeves where cable was already terminated. Both carry the flame retardant wet service formulation and the heavy wall gives real abrasion allowance.
Manufacturing Process
Flame retardant grade formulated for wet and underground service with the thickened heavy wall design. Adhesive lined for every position on the platform.
Supply Chain Coordination
Material delivered to the supply base ahead of the weather window with a float allowance so a lost window did not create a material shortage.
Quality Control
Per lot testing plus CCS ABS and DNV approval documentation assembled for the survey file.
Final Result
The refurbishment completed within the available weather windows. The surveyor accepted the material on the documentation supplied without requiring additional testing.
Customer Benefit
One material that satisfies both the fire requirement and the mechanical requirement, with the paperwork the surveyor needs already assembled.
Products
Products Supplied on This Project
S3(h) Heavy Wall FR
The toughest tube in the S3 family combining flame retardant marine formulation with a thickened heavy wall
VIEW DETAILSR1 Repair Sleeve
A rail and channel closure sleeve that repairs a damaged cable jacket without cutting the cable or removing the terminations
VIEW DETAILSS3 Medium Wall FR
Flame retardant medium wall tubing formulated for wet and underground service on vessels platforms shipyards and harbours
VIEW DETAILSY2 Cable End Caps
Adhesive lined molded caps that seal a cut cable end against water ingress during storage transport and installation
VIEW DETAILSFAQ
Questions About This Project
When do I need heavy wall rather than medium wall
Does the heavy wall reduce flexibility
What documentation does a surveyor need
How is material prepared in a salt environment
Still need an answer ask our engineers on WhatsApp
More Cases
Other Projects
15 kV Feeder Refurbishment for a Distribution Utility in Southeast Asia
820 terminations and 140 joints delivered against a 14 week outage programme
READ CASE →Retrofitting Creepage on Flashover Prone Outdoor Terminations
Rain sheds fitted to 96 existing 33 kV terminations without rebuilding any of them
READ CASE →Accessory Package for a 350 MW Solar Collector Circuit
Take off from a single line diagram consolidated 14 part numbers down to 5
READ CASE →Discuss a Project Like This One
Tell us the voltage class the quantity and the programme. We will tell you what is realistic before you commit.