Product Overview
ST/UPC-ST/UPC SM Simplex Patchcord is part of the fiber optic patchcord range built by Ever Expresslink Limited in Ningbo, China. It is built on the ST (Straight Tip) interface.
ST fiber cable connector has a bayonet-style housing and a long spring-loaded ferrule hold the fiber. They are available in both multimode or singlemode versions. Horizontally mounted simplex and duplex adapters are available with metal or plastic housing, with a choice of phosphor bronze or zirconia split sleeve. The ST fiber patch is one of the older generations of connector, but is still widely used for multimode networks, including LANs for buildings and campuses.
ST mounts a 2.5 mm ferrule in a bayonet coupling that locks with a quarter turn against a spring. The bayonet pin has to clear the slot fully. A partially rotated ST looks seated but sits off the reference plane and reads high loss.
Single-mode fiber carries one propagation mode in a 9 µm core, so pulse spreading stays low and the link budget is set by loss rather than dispersion. Use it for access, metro and long-haul spans, for PON distribution and for anything that has to survive a future speed upgrade.
UPC is an ultra-physical-contact polish: a domed, highly polished end face that presses fiber core to fiber core. It is the default for most data, enterprise and general telecom patching.
Also Searched As
Key Benefits
- Supplied as ST/UPC-ST/UPC SM Simplex Patchcord, so the part you receive matches the designation you ordered against
- UPC end face: It is the default for most data, enterprise and general telecom patching.
- Single Mode at 9/125 µm: Use it for access, metro and long-haul spans, for PON distribution and for anything that has to survive a future speed upgrade.
- Simplex construction: A single fiber in one jacket, terminated at both ends. Use it for one-way paths, for monitoring taps and wherever a duplex pair would just be waste.
- Factory termination and polishing under controlled conditions, not a crimp done on a ladder
- One supplier for every mainstream connector, polish and fiber-mode combination
Problems It Solves
- Mixed connector estates where the equipment port and the distribution frame never match
- Jacket ratings that fail a building inspection after the cabling is already installed
- Long lead times on non-standard lengths, which stall a commissioning window
- Link budgets that pass on paper and fail on site because connector loss was assumed rather than measured
Application Scenarios
- Telecommunications
- CATV
- LAN
- Legacy multimode building backbones
- Cross-connecting between patch panels in a campus riser
- Building portable test leads for field engineering kits
Who It Is For
- OEM equipment makers bundling cords with their own hardware
- FTTH and access network operators patching between splitter shelves and subscriber feeds
- Data-center and enterprise cabling contractors building out patch fields
- System integrators commissioning transmission and monitoring equipment
Technical Features
- ST (Straight Tip) interface
- The bayonet pin has to clear the slot fully. A partially rotated ST looks seated but sits off the reference plane and reads high loss.
- Single Mode fiber at 9/125 µm
- Zirconia ceramic ferrule with pre-polished end face
- Spring-loaded ferrule assembly to maintain physical contact under load
- Bend-controlled boot to protect the fiber at the connector exit
- Jacket and boot color coded by polish type for quick field identification
Materials
- Zirconia ceramic ferrule
- Copper alloy or stainless coupling hardware
- PVC, LSZH or OFNP jacket depending on the building code that applies
- Aramid yarn strength members
- Thermoplastic boot and housing
Specifications
| Product Designation | ST/UPC-ST/UPC SM SIMPLEX PATCHCORD |
|---|---|
| Product Family | Fiber Optic Patchcord |
| Connector Interface | ST (Straight Tip) |
| End Face Polish | UPC |
| Fiber Mode | Single Mode (9/125 µm) |
| Cable Structure | Simplex |
| Referenced Standards | IEC 61 754-2 |
| Manufactured In | Ningbo, China |
| Warranty | One year against defects in materials and workmanship |
Values shown are those carried by the product designation. Dimensional and optical values for a specific order are confirmed on the quotation.
Manufacturing Process
- Fiber and connector kitting against the works order
- Epoxy injection and fiber insertion into the ferrule
- Oven curing of the epoxy bond
- Cleave and multi-stage polish to the specified end-face profile
- Interferometric and visual end-face inspection
- Insertion loss and return loss test on every unit
- End-cap fitting, labeling and individual bagging
Quality Control
- End-face geometry inspection before the cord is allowed to be tested
- Insertion loss and return loss measured per assembly, not per batch
- Tensile and side-pull checks on sample units from each production run
- Visual inspection for jacket damage, boot seating and label accuracy
- Final cleanliness check and end-cap fitting before packing
Customization Options
- Any length from short equipment jumpers to long riser runs
- Mixed connector types on each end for equipment-to-frame transitions
- UPC or APC polish specified per end
- PVC, LSZH, armoured or outdoor-rated jacket
- Custom boot colors, jacket printing and private-label packaging
Compared With Other Options
| SC | SC pushes straight in; ST needs a twist but is quick once the technique is habitual |
|---|---|
| FC | Both use a 2.5 mm ferrule; FC screws down for vibration, ST trades that for speed |
| APC version | APC adds an eight degree angle so reflections leave the core, which matters on PON, CATV and RF-over-glass paths. It is not interchangeable with this part. |
| Multimode version | Multimode is cheaper to drive over short in-building distances but cannot carry the reach or the upgrade headroom of single mode. |
Handling ST/UPC-ST/UPC SM Simplex Patchcord
Before You Order
- Confirm the connector type and polish at both ends against the equipment and the frame
- Confirm fiber mode and core size match the installed plant end to end
- Inspect and clean both end faces before every mating, including on a new cord
In Service
- Seat the connector fully until the latch or nut engages, then verify with a power meter
- Keep the bend radius above the cord's rated minimum through the whole route
- Re-cap any cord taken out of service instead of leaving the ferrule exposed
Questions About ST/UPC-ST/UPC SM Simplex Patchcord
What do you need from us to quote ST/UPC-ST/UPC SM Simplex Patchcord?
The quantity, the destination and anything that has to match on your side: connector and polish at each end, fiber mode and core size, and length where the item is an assembly. If you are matching a part you already buy, send the sample and we will quote against it.
Can ST/UPC-ST/UPC SM Simplex Patchcord be supplied with a different connector interface?
Yes. ST (Straight Tip) is what this designation carries, and the same family is stocked across the other mainstream connector standards. Tell us the port you have to mate with and we will confirm the equivalent part.
Is ST/UPC-ST/UPC SM Simplex Patchcord available in the other fiber mode?
This item is single mode. Single-mode alignment tolerance is tight. End-face cleanliness matters more here than on any multimode link. The corresponding version in the other fiber mode is available; confirm the installed plant at both ends before ordering.
What connector and polish combinations can you supply on a patch cord?
We build cords with FC, SC, LC, ST, MU, MT-RJ and E2000 ends in UPC, APC and PC polish, including mixed-connector cords with a different type on each end. Tell us the equipment port and the frame port and we will quote the assembly that bridges them.
Can I order non-standard lengths?
Yes. Cords are cut and terminated to the length on your order rather than to a fixed catalog ladder, which is usually cheaper than buying long cords and coiling the slack.
More Fiber Optic Patchcord

LC/PC-LC/PC 62.5/125 MM Duplex Patchcord
We offer LC fiber cables and LC fiber patch, including single mode 9/125 and multimode 50/125, multimode 62.5/125, LC-LC, LC-SC, LC-ST, LC-MU, LC-MTRJ, LC-MPO.
View Details
LC/PC-LC/PC 62.5/125 MM Simplex Patchcord
We offer LC fiber cables and LC fiber patch, including single mode 9/125 and multimode 50/125, multimode 62.5/125, LC-LC, LC-SC, LC-ST, LC-MU, LC-MTRJ, LC-MPO.
View Details
LC/UPC-LC/UPC SM Simplex Patchcord
We offer LC fiber cables and LC fiber patch, including single mode 9/125 and multimode 50/125, multimode 62.5/125, LC-LC, LC-SC, LC-ST, LC-MU, LC-MTRJ, LC-MPO.
View Details
MT-RJ/UPC-MT-RJ/UPC SM Duplex Patchcord
The singlemode or multimode MT-RJ fiber cable available from Huihong are used in two fiber applications and are well suited for high density applications.
View DetailsGuides Cases and Industries
Choosing a Fiber Media Converter
Single fiber or dual fiber, fixed optics or SFP, standalone or chassis: four decisions that determine whether the link works and whether it scales.
Buying GuideHow to Choose a Fiber Optic Connector Type
FC SC LC ST MU MT-RJ and E2000 compared by what actually decides the choice: the port you have to mate with the space you have and how often it gets touched.
Process GuideUPC and APC End Face Polish Explained
Why an eight degree angle changes where reflected light goes, when that matters enough to pay for it, and what happens if the two are mated.
Deployment ProfileCATV Optical Level Balancing
Bringing an optical distribution tree into level, and keeping reflections out of the picture
Deployment ProfileCentral Office ODF Consolidation
Turning a fiber plant that grew without a frame into one a new engineer can read
IndustryIndustrial and Medical Optical Links
Fiber links in environments where electrical noise, isolation or geometry rules out copper
IndustryTelecom and Carrier Networks
Passive components for access, metro and transmission plant that has to stay up for decades
Request Pricing For ST/UPC-ST/UPC SM Simplex Patchcord
Tell us the quantity and destination. If you are matching a part you already buy, send the sample and we will quote against it.