SC/UPC-SC/UPC SM Simplex Patchcord

Fiber Optic PatchcordUPCSingle ModeSimplex

SC/UPC-SC/UPC SM Simplex Patchcord is part of the fiber optic patchcord range built by Ever Expresslink Limited in Ningbo, China. It is built on the SC (Subscriber Connector) interface.

Factory-terminated jumpers that turn a planned link budget into a working one

Interested in SC/UPC-SC/UPC SM Simplex Patchcord

Email the model and quantity with your destination country. We reply with pricing, lead time and a datasheet.

Product Overview

SC/UPC-SC/UPC SM Simplex Patchcord is part of the fiber optic patchcord range built by Ever Expresslink Limited in Ningbo, China. It is built on the SC (Subscriber Connector) interface.

SC fiber cable is one of the earliest stype and one of the most commonly used fiber optic cable, it is convenient to use and cost saving - It is the most cheapest type fiber optic cable. SC fiber patch is widely uesed in fiber optic networks. SC fiber patch cable is with zirconia sleeve and plastic housing.

SC pairs a 2.5 mm ferrule with a square push-pull housing that clicks into the adapter and releases by pulling the body straight back. SC bodies clip together into duplex pairs. Check polarity before you clip, because a reversed duplex clip is easy to build and hard to spot in a cabinet.

Single-mode fiber carries one propagation mode in a 9 µm core, so pulse spreading stays low and the link budget is set by loss rather than dispersion. Use it for access, metro and long-haul spans, for PON distribution and for anything that has to survive a future speed upgrade.

UPC is an ultra-physical-contact polish: a domed, highly polished end face that presses fiber core to fiber core. It is the default for most data, enterprise and general telecom patching.

Also Searched As

SC-LCSC-STSC-FCSC-MUSC-MT-RJSC-E20009/12550/12562.5/125simplexduplex

Key Benefits

  • Supplied as SC/UPC-SC/UPC SM Simplex Patchcord, so the part you receive matches the designation you ordered against
  • UPC end face: It is the default for most data, enterprise and general telecom patching.
  • Single Mode at 9/125 µm: Use it for access, metro and long-haul spans, for PON distribution and for anything that has to survive a future speed upgrade.
  • Simplex construction: A single fiber in one jacket, terminated at both ends. Use it for one-way paths, for monitoring taps and wherever a duplex pair would just be waste.
  • Consistent boot and jacket color coding, which keeps a dense patch field readable
  • Bulk packing options that suit a rollout rather than a single repair

Problems It Solves

  • Jacket ratings that fail a building inspection after the cabling is already installed
  • Long lead times on non-standard lengths, which stall a commissioning window
  • Link budgets that pass on paper and fail on site because connector loss was assumed rather than measured
  • Cords that drift out of spec after repeated re-patching in an active patch field

Application Scenarios

  • Telecommunications
  • CATV
  • LAN
  • FTTH terminal boxes and splice closures
  • Patching optical line terminals to splitter shelves inside a central office
  • Connecting transceivers to an optical distribution frame in a data hall

Who It Is For

  • System integrators commissioning transmission and monitoring equipment
  • Distributors who need one supplier for a full connector and polish matrix
  • OEM equipment makers bundling cords with their own hardware
  • FTTH and access network operators patching between splitter shelves and subscriber feeds

Technical Features

  • SC (Subscriber Connector) interface
  • SC bodies clip together into duplex pairs. Check polarity before you clip, because a reversed duplex clip is easy to build and hard to spot in a cabinet.
  • Single Mode fiber at 9/125 µm
  • Bend-controlled boot to protect the fiber at the connector exit
  • Jacket and boot color coded by polish type for quick field identification
  • Individually bagged and end-capped so end faces stay clean until installation
  • Zirconia ceramic ferrule with pre-polished end face

Materials

  • Zirconia ceramic ferrule
  • Copper alloy or stainless coupling hardware
  • PVC, LSZH or OFNP jacket depending on the building code that applies
  • Aramid yarn strength members
  • Thermoplastic boot and housing

Specifications

Product DesignationSC/UPC-SC/UPC SM SIMPLEX PATCHCORD
Product FamilyFiber Optic Patchcord
Connector InterfaceSC (Subscriber Connector)
End Face PolishUPC
Fiber ModeSingle Mode (9/125 µm)
Cable StructureSimplex
Referenced StandardsIEC 61 754-4; TIA/EIA 604-3-A
Manufactured InNingbo, China
WarrantyOne year against defects in materials and workmanship

Values shown are those carried by the product designation. Dimensional and optical values for a specific order are confirmed on the quotation.

Manufacturing Process

  • Fiber and connector kitting against the works order
  • Epoxy injection and fiber insertion into the ferrule
  • Oven curing of the epoxy bond
  • Cleave and multi-stage polish to the specified end-face profile
  • Interferometric and visual end-face inspection
  • Insertion loss and return loss test on every unit
  • End-cap fitting, labeling and individual bagging

Quality Control

  • End-face geometry inspection before the cord is allowed to be tested
  • Insertion loss and return loss measured per assembly, not per batch
  • Tensile and side-pull checks on sample units from each production run
  • Visual inspection for jacket damage, boot seating and label accuracy
  • Final cleanliness check and end-cap fitting before packing

Customization Options

  • Any length from short equipment jumpers to long riser runs
  • Mixed connector types on each end for equipment-to-frame transitions
  • UPC or APC polish specified per end
  • PVC, LSZH, armoured or outdoor-rated jacket
  • Custom boot colors, jacket printing and private-label packaging

Compared With Other Options

LCLC is half the footprint and doubles port density; SC is easier to handle in a crowded closure
FCFC's threaded nut resists vibration; SC is faster to patch and re-patch
APC versionAPC adds an eight degree angle so reflections leave the core, which matters on PON, CATV and RF-over-glass paths. It is not interchangeable with this part.
Multimode versionMultimode is cheaper to drive over short in-building distances but cannot carry the reach or the upgrade headroom of single mode.
Use Guide

Handling SC/UPC-SC/UPC SM Simplex Patchcord

Before You Order

  • Confirm the connector type and polish at both ends against the equipment and the frame
  • Confirm fiber mode and core size match the installed plant end to end
  • Inspect and clean both end faces before every mating, including on a new cord

In Service

  • Seat the connector fully until the latch or nut engages, then verify with a power meter
  • Keep the bend radius above the cord's rated minimum through the whole route
  • Re-cap any cord taken out of service instead of leaving the ferrule exposed
FAQ

Questions About SC/UPC-SC/UPC SM Simplex Patchcord

What do you need from us to quote SC/UPC-SC/UPC SM Simplex Patchcord?

The quantity, the destination and anything that has to match on your side: connector and polish at each end, fiber mode and core size, and length where the item is an assembly. If you are matching a part you already buy, send the sample and we will quote against it.

Can SC/UPC-SC/UPC SM Simplex Patchcord be supplied with a different connector interface?

Yes. SC (Subscriber Connector) is what this designation carries, and the same family is stocked across the other mainstream connector standards. Tell us the port you have to mate with and we will confirm the equivalent part.

Is SC/UPC-SC/UPC SM Simplex Patchcord available in the other fiber mode?

This item is single mode. Single-mode alignment tolerance is tight. End-face cleanliness matters more here than on any multimode link. The corresponding version in the other fiber mode is available; confirm the installed plant at both ends before ordering.

Can I order non-standard lengths?

Yes. Cords are cut and terminated to the length on your order rather than to a fixed catalog ladder, which is usually cheaper than buying long cords and coiling the slack.

What is the difference between UPC and APC on a patch cord?

UPC uses a domed end face for direct core contact. APC adds an eight degree angle so reflected light leaves the core, which matters on PON and RF-over-glass paths. APC cords are green, UPC cords are blue, and the two must not be mated to each other.