When the circuit runs past the limit of a hot water pump, this is the horizontal model that carries a 240 degree fluid rating.

SKWS high temperature horizontal centrifugal pump with flanged casing

Overview

What This Pump Does

The SKWS is the high temperature build of the horizontal platform, published with a maximum permissible fluid temperature of 240 degrees Celsius for pressurised cyclic transport.

It keeps the hydraulics and the footprint of the rest of the SKW family, covering 1.5 to 1500 m3/h with heads to 150 m and drives to 160 kW, so a temperature upgrade does not force a change of pump size.

Working PrincipleCentrifugal
Main applicationsWater
DriverElectric motor
Power Specs380/415 V 220v,3phase;50hz/60hz
Max. permissible fluid temperature240°C
Type of connectionFlange

Key Benefits

What Changes At 240 Degrees

240 Degree Fluid Rating

The highest published temperature in the centrifugal range, for pressurised circulation duty.

Same Hydraulic Platform

Flow, head and connection sizes match the rest of the SKW family, so pipework and duty points carry over.

Seal Arrangement For Heat

Hard alloy mechanical seal faces or a packing gland, specified against temperature and system pressure together.

Material Options

Cast iron, stainless steel or bronze wetted parts depending on the circuit fluid.

Application Scenarios

Where It Is Installed

High Temperature Process Circuits

Pressurised circulation above the range of a standard hot water pump.

Heat Recovery Loops

Circuits recovering heat from process streams where temperatures stay high continuously.

Industrial Heating Systems

Plant heating where the medium is water held above its atmospheric boiling point under pressure.

Who It Is For

  • Process engineers specifying high temperature circulation
  • Energy and heat recovery project contractors
  • Plants running pressurised water above 120 degrees
  • Maintenance teams replacing pumps that fail at temperature

Problems It Solves

Repeated seal failure on hot circuits

A pump rated for the actual circuit temperature stops the cycle of seal replacements that follows an undersized rating.

Pump size changes with temperature upgrade

Because the platform is shared, moving to the high temperature build does not change flow, head or connection sizes.

Fluid selection is unclear

Above 120 degrees the fluid and the pressurisation matter as much as the pump. We ask for both before quoting.

Technical Features

How It Is Built

  • Maximum permissible fluid temperature 240 degrees Celsius
  • Single stage single end suction hydraulics
  • Mechanical seal with hard alloy faces or packing gland
  • Free passage 0.2 mm, maximum specific gravity 1.1
  • Flanged connections, horizontal installation
  • Drive ratings to 160 kW at 380 to 415 V three phase

Specifications

Technical Data

SKWS published data. High temperature service depends on correct pressurisation, so send the circuit design pressure with the duty.

Working PrincipleCentrifugal
Main applicationsWater
DriverElectric motor
Power Specs380/415 V 220v,3phase;50hz/60hz
Max. permissible fluid temperature240°C
Type of connectionFlange
Installation positionHorizontal
Casing/Impeller materialCast iron, Stainless steel/Cast iron, Stainless steel, Bronze
Shaft seal typeMechanical seal; Packing gland
Free passage0.2 mm
Maximum gravity1.1
Maximum drive rating160kW(215hp)
Maximum caliber20 inch(500mm)
Maximum head150m
Flow rate range1.5-1500 m3/h ( 25-25000 l /m)

Materials And Process

What Goes Into Every Unit

Materials

  • Cast iron or stainless steel casing
  • Cast iron, stainless steel or bronze impeller
  • Hard alloy seal faces
  • Gaskets rated for the circuit temperature

Manufacturing And Assembly

  • Casting and machining at the works
  • Balanced impeller assembly
  • Hydraulic test before dispatch
  • Documentation package with the order

Quality Control

  • Seal arrangement checked against the stated temperature
  • Hydraulic performance test recorded
  • Factory acceptance test record issued

Customization Options

  • Material selection for the circuit fluid
  • Seal type and face material
  • Motor rating and supply voltage
  • Flange standard and drilling

Compared With Other Options

SKWR hot water pumpThe SKWR is rated to 120 degrees. Above that, this model is the correct one rather than an uprated version of the other.
SKGS vertical high temperature pumpSame 240 degree rating in a vertical inline body, when floor space rather than headroom is the constraint.

Use Guide

Operating At High Temperature

Confirm Pressurisation

Water above 100 degrees needs the circuit held above its vapour pressure. Confirm this before commissioning.

Heat Up Slowly

Raise circuit temperature in stages so the casing and seal reach temperature evenly.

Vent And Check

Vent thoroughly during heat up, since vapour pockets at the pump cause immediate seal damage.

Log The Baseline

Record flow, pressure, temperature and current once stable, and compare monthly.

Answers

SKWS High Temperature Centrifugal Pump FAQ

What is the maximum fluid temperature?

240 degrees Celsius as published on the SKWS data sheet.

Can it run on thermal oil?

For thermal oil circuits use the magnetic drive heat transfer line rated to 350 degrees, which has no shaft seal.

Does the high temperature build change the flow range?

No. Flow is 1.5 to 1500 m3/h with head to 150 m, the same as the rest of the family.

What seal is used?

Mechanical seal with hard alloy rotating and stationary rings, or a packing gland, selected against temperature and pressure.

What has to be right in the circuit?

Pressurisation, venting and expansion. A correctly rated pump in a badly pressurised circuit will still fail.

Related Equipment

Related Equipment From The Same Line

The rest of the high temperature and hot water range.

Hot oil pump head coupled to a motor on a machine frame

High Temperature Pumps

Hot Oil Pump

Magnetic drive heat transfer pump for hot oil and hot water to 350 degrees.

View specifications →

Need SKWS High Temperature Centrifugal Pump Sized For Your Duty Point

Send the circuit temperature, the design pressure and the flow, and we will confirm the build and the seal.