Skip to content
Pumps tanks mixers and sanitary fittings built in Wenzhou since 2002
Peristaltic dosing pump head with tube and drive motor

Industry Application

Dosing And Transfer Pumps For Water Treatment Plants

Treatment plants live on small accurate flows: coagulant, polymer, chlorine, acid and caustic. That is a different problem from moving the main stream, and it needs a different pump.

What Goes Wrong On This Duty

Dosing chemicals destroy the pump

Sodium hypochlorite, acid and polymer attack seals and valves. A peristaltic pump keeps the liquid inside a tube, and a magnetic drive pump has no seal at all.

The dose drifts with line pressure

Positive displacement pumps deliver a fixed volume per revolution, so the dose follows speed rather than downstream pressure.

Small pumps gas lock

Chlorine solutions release gas that stops a diaphragm pump. A tube pump simply passes the bubble through.

What Buyers Ask For

  • Repeatable dosing that a controller can trim
  • Wetted parts that survive the chemical, not just the pressure
  • Pumps that tolerate running dry when a tank empties
  • Simple maintenance: change a tube rather than rebuild a head
  • Transfer pumps for backwash and filter feed duty

Recommended Equipment

Dosing Pumps Plus The Transfer Pumps Around Them

Tube and micro gear pumps for chemical dosing, centrifugal pumps for filter feed, backwash and general transfer.

SK165 peristaltic pump head with tube and rollers

Peristaltic And Dosing Pumps

SK165 Peristaltic Pump

Tube pump for analytical instruments and feeding equipment.

View specifications →
Peristaltic dosing pump head with tube and drive motor

Peristaltic And Dosing Pumps

Dosing Pump

Peristaltic dosing build of the SK165 for chemical feed.

View specifications →
Tube pump head with flexible tube fitted between rollers

Peristaltic And Dosing Pumps

Tube Pump

The SK165 head supplied as a general purpose tube pump.

View specifications →
Magnetic drive pump with green motor and stainless pump head

Micro Gear And Magnetic Drive Pumps

Magnetic Pump

Seal free magnetic drive pump for hazardous and volatile liquids.

View specifications →
Magnetic gear pump with blue motor and stainless gear head

Micro Gear And Magnetic Drive Pumps

Magnetic Gear Pump

Magnetic drive gear pump for continuous circulation loops.

View specifications →

Typical Scenarios

Where The Equipment Sits

Coagulant And Polymer Dosing

Feeding a measured stream into the flow at a rate the controller sets from turbidity or flow signal.

Disinfection

Hypochlorite and other disinfectant dosing where gassing and corrosion rule out most pump types.

Filter Feed And Backwash

Centrifugal pumps moving the main stream through filters and reversing for backwash duty.

How We Work

Specifying A Dosing Installation

Chemical And Concentration

The chemical decides the tube or the wetted material. Concentration and temperature matter as much as the name.

Dose Rate Range

Minimum and maximum millilitres or litres per hour, and how the rate will be commanded.

Back Pressure

Injection point pressure sets the pump duty. A dosing pump with too little pressure capability simply stops delivering.

Control And Spares

Fixed speed, variable speed or stepper control, plus spare tubes and seals held on site.

Delivery

What You Get With The Order

  • Pump matched to the chemical, not just the flow
  • Spare tube sets supplied with peristaltic pumps
  • Magnetic drive options where no leak path is acceptable
  • Operation and maintenance manual covering tube change intervals
  • Transfer and filter feed pumps from the same supplier
Three peristaltic tube pump heads in blue grey and amber housings
Tube pumps keep the chemical inside the tube, so maintenance is a tube change rather than a rebuild.

Answers

Water Treatment FAQ

Which pump suits hypochlorite dosing?

A peristaltic pump handles gassing solutions well because the bubble passes through the tube. Send the concentration so the tube material is chosen correctly.

How accurate is the dose?

Delivered volume per revolution is fixed, so with controlled speed the dose is repeatable. For an exact figure against your chemical and back pressure, send both with the enquiry.

What if the chemical tank runs dry?

Peristaltic pumps tolerate dry running. Gear pumps do not, so on those duties we advise on level protection.

Can the pump be controlled from our PLC?

Yes. The stepper motor version is driven by your controller, and variable speed drives can be used on the gear pump range.

Do you supply the transfer pumps as well?

Yes. Filter feed, backwash and general transfer duties are covered by the centrifugal range, including chemical versions with stainless wetted parts.

Name The Chemical And The Dose Rate

Chemical, concentration, rate range and injection pressure are enough to specify the pump and the consumables.