Overview

What This Pump Does

The LP2251 heat transfer pump is built for high temperature duty to 350 degrees Celsius, lifting hot water and hot oil that contains no solids and is low in corrosiveness. The motor has no axis seal, with the magnetic force leading the drive.

Four builds cover the usual small circuit duties: 90 W at 8 m head and 10 L per minute, 180 W at 20 m and 30 L per minute, 370 W at 35 m and 30 L per minute, and 500 W at 40 m and 30 L per minute, running at 1400 or 2800 rpm.

Three-phase230V±10%(220-240V
Single-phase230V ±10% (220-240V)

Key Benefits

Why Hot Circuits Use This Pump

No Axis Seal

Magnetic force leads the drive, so there is no shaft seal to degrade at temperature and no leak path on a hot oil line.

Rated To 350 Degrees

The published rating for heat transfer duty, well beyond the limit of a standard water pump.

Four Sizes For Real Circuits

90 W to 500 W covers the pump sizes that thermal oil skids and heated tanks actually need.

Two Speeds

1400 or 2800 rpm lets the circuit be matched without throttling the line.

Application Scenarios

Where It Is Installed

Thermal Oil Circuits

Circulating heat transfer oil between heater and press, reactor or drying tunnel.

Plating And Developing Lines

Galvanisation, film and television developing, printing, spinning and weaving lines with hot liquid.

Process And Utility Heat

Petroleum, chemical, drug manufacture, environmental protection, food and water treatment duties listed on the data sheet.

Who It Is For

  • Thermal oil system builders
  • Plating and surface treatment lines
  • Print, textile and film processing plants
  • Process engineers replacing leaking hot circuit pumps

Problems It Solves

Hot oil destroys seals

There is no axis seal to destroy, which is the single biggest maintenance item removed from a hot circuit.

A leak on a hot line is dangerous

A closed pump head removes the leak path that makes unattended hot oil circuits risky.

Water pumps are out of range

Standard water pumps stop around 80 degrees. This line is built for heat transfer duty to 350 degrees.

Technical Features

How It Is Built

  • Heat transfer duty to 350 degrees Celsius
  • No axis seal, drive carried by magnetic force
  • Builds of 90 W, 180 W, 370 W and 500 W
  • Heads from 8 m to 40 m, flows from 10 to 30 L per minute
  • Speed 1400 or 2800 rpm
  • Single phase and three phase supply at 220 to 240 V

Specifications

Technical Data

Published LP2251 data. The pump is for hot liquid without solids and with low corrosiveness, so confirm the fluid as well as the temperature.

Three-phase230V±10%(220-240V
Single-phase230V ±10% (220-240V)

Materials And Process

What Goes Into Every Unit

Materials

  • Stainless steel wetted pump head
  • Magnetic coupling assembly
  • High temperature internal components

Manufacturing And Assembly

  • Pump head machining and assembly
  • Magnet coupling fitted and checked
  • Run test before packing
  • Documentation issued with the order

Quality Control

  • Coupling and housing checked at assembly
  • Run test before dispatch
  • Test record available with the order

Customization Options

  • Motor rating for the circuit duty
  • Speed selection at 1400 or 2800 rpm
  • Single phase or three phase supply
  • Connection arrangement to the circuit

Compared With Other Options

SKWS high temperature centrifugal pumpThe SKWS handles far larger flows on pressurised water to 240 degrees. This pump is for small hot oil circuits with no seal at all.
Sealed hot oil pumpA sealed pump costs less but puts a wearing seal on a hot oil line, which is where most failures and leaks start.

Use Guide

Commissioning A Heat Transfer Pump

Fill And Vent

Vent the circuit completely before the first start so the pump is never run on vapour.

Raise Temperature Gradually

Bring the circuit up in stages rather than in one step.

Protect Against Dry Running

The pump is not designed to run dry. Fit level or flow protection in the circuit.

Record Flow And Delta T

Log flow and temperature difference once hot as a baseline for later checks.

Answers

Hot Oil Pump FAQ

How hot can the fluid be?

The line is rated to 350 degrees Celsius for heat transfer duty.

Which fluids are suitable?

Hot water and hot oil without solid content and with low corrosiveness.

What flows and heads are available?

90 W at 8 m and 10 L per minute, 180 W at 20 m and 30 L per minute, 370 W at 35 m and 30 L per minute, and 500 W at 40 m and 30 L per minute.

Why is there no seal?

The motor has no axis seal. Magnetic force leads the drive through a closed housing.

What speeds are offered?

1400 and 2800 rpm.

Related Equipment

Related Equipment From The Same Line

Other high temperature and seal free options.

Magnetic drive pump with green motor and stainless pump head

Micro Gear And Magnetic Drive Pumps

Magnetic Pump

Seal free magnetic drive pump for hazardous and volatile liquids.

View specifications →
K2CY external gear pump with blue body and red coupling guard

Gear Pumps

K2CY Gear Pump

External gear pump for lubricating oil fuel and hydraulic duty.

View specifications →

Need Hot Oil Pump Sized For Your Duty Point

Send the fluid, the temperature, the flow and the circuit resistance and we will confirm the build and the speed.