Centrifugal Pumps
SKS Horizontal Water Pump
Traditional coupled end suction pump with the seal serviceable in place.
View specifications →Product Lines
Centrifugal PumpsSanitary PumpsMicro Gear And Magnetic Drive PumpsPeristaltic And Dosing PumpsRubber Lobe PumpsProgressing Cavity PumpsGear PumpsHigh Temperature PumpsSubmersible Aerators And MixersStainless Steel Tanks And VesselsHigh Shear EmulsifiersMagnetic MixersDefoaming MachinesVinegar AcetatorsSanitary Valves And FittingsSanitary Manhole CoversStainless Steel Pipe FittingsIndustries
Water Supply And DrainageWastewater And SewageWater TreatmentChemical And PetrochemicalFood And BeveragePharmaceutical And BiotechPulp And PaperMining And MarineSolutions
Sanitary Process Line PackagesWastewater Aeration And MixingThermal Oil And Hot Water CircuitsChemical Dosing And TransferKnowledge CenterDocumentationAboutContactCentrifugal Pumps
A direct coupled single stage end suction pump with no separate coupling, which is what removes about 30 percent of the footprint an ordinary horizontal set needs.

Overview
The SKW is the workhorse of the horizontal range: a single stage, single end suction pump with the motor and pump body integrated, so there is no coupling, no alignment and no separate baseplate. It moves clear water and liquids with similar chemical and physical properties, at temperatures up to 80 degrees Celsius.
Because the set is compact and can be supplied with an IP54 outdoor motor, it can be installed without a pump room. Flow covers 1.5 to 1500 m3/h with heads to 150 m and drive ratings to 160 kW.
| Working Principle | Centrifugal |
|---|---|
| Main applications | Water |
| Driver | Electric motor |
| Power Specs | 380/415 V 220v,3phase;50hz/60hz |
| Max. permissible fluid temperature | 80°C |
| Type of connection | Flange |
Key Benefits
The integrated motor and pump body cut occupied area by about 30 percent against an ordinary horizontal pump with a coupling and frame.
With IP54 outdoor motors the set can be installed outdoors, which removes a building from the project.
Direct connection simplifies the intermediate structure, and dynamic and static balancing of the impeller keeps vibration and noise down and bearing life up.
Mechanical seal with hard alloy rotating and stationary rings, or packing gland where the site prefers to adjust a gland.
Application Scenarios
Pressure increasing supply for high buildings, where the set holds head across the day rather than cycling.
Cold and warm water circulation and matching equipment, sized against circuit resistance.
Pressure increasing for fire fighting, garden irrigation and long distance transportation duty.
A close coupled set removes the coupling, the frame and the alignment work, which is often what makes a replacement fit.
A drain hole at the lower part of the pump body and pressure holes at the inlet and outlet flanges make routine work and pressure checks straightforward.
Horizontal inlet with vertical upward outlet suits the way most plant room pipework is routed.
Technical Features
Specifications
Figures below are from the SKW data sheet. The model is selected against your duty point, so the flow and head you need sit inside these limits rather than at them.
| Working Principle | Centrifugal |
|---|---|
| Main applications | Water |
| Driver | Electric motor |
| Power Specs | 380/415 V 220v,3phase;50hz/60hz |
| Max. permissible fluid temperature | 80°C |
| Type of connection | Flange |
| Installation position | Horizontal |
| Casing/Impeller material | Cast iron, Stainless steel/Cast iron, Stainless steel, Bronze |
| Shaft seal type | Mechanical seal; Packing gland |
| Free passage | 0.2 mm |
| Maximum gravity | 1.1 |
| Maximum drive rating | 160kW(215hp) |
| Maximum caliber | 20 inch(500mm) |
| Maximum head | 150m |
| Flow rate range | 1.5-1500 m3/h ( 25-25000 l /m) |
Materials And Process
| SKS traditional coupled pump | The SKW is more compact and needs no alignment. The SKS keeps a coupling, which lets the seal be serviced without moving the motor. |
|---|---|
| SKG vertical inline pump | The SKG drops into the pipe run and saves floor area. The SKW is easier to reach from all sides for maintenance. |
Use Guide
Confirm flow, static lift and pipe losses before installation. A throttled discharge valve means the pump was sized on a guess.
Horizontal inlet, vertical upward outlet, supported pipework and no strain on the flanges.
Fill and vent the casing before the first start. Dry running destroys the seal faces in seconds.
Check for leakage at the seal, note the running current and record the duty so later drift can be measured.
Answers
Flow range is 1.5 to 1500 m3/h, maximum head 150 m, maximum drive rating 160 kW and maximum caliber 500 mm, which is 20 inch.
Up to 80 degrees Celsius on this model. For hotter duty use the SKWR hot water or SKWS high temperature version.
No. Free passage is 0.2 mm, so this is a clear liquid pump. For solids use the rubber lobe or progressing cavity lines.
380 to 415 V, also 220 V, three phase, 50 or 60 Hz. State the site supply with the enquiry.
Yes, with IP54 outdoor motors, which is one reason this series is used where there is no pump room.
Related Equipment
Same hydraulic family, different mounting and duty ratings.
Centrifugal Pumps
Traditional coupled end suction pump with the seal serviceable in place.
View specifications →
Centrifugal Pumps
Vertical inline pump for clear water where floor space is scarce.
View specifications →
Centrifugal Pumps
Horizontal pump for pressurised hot water circulation to 120 degrees.
View specifications →
Centrifugal Pumps
Stainless horizontal pump for corrosive liquids to 120 degrees.
View specifications →Keep Reading
Send flow, static lift and pipe losses and we will confirm the impeller and motor rating rather than the frame size.