Skip to content
Pumps tanks mixers and sanitary fittings built in Wenzhou since 2002

Micro Gear And Magnetic Drive Pumps

Magnetic Gear Pump

The circulation build of the magnetic drive family, for loops that have to keep running for months without anyone touching them.

Magnetic gear pump with blue motor and stainless gear head

Overview

What This Pump Does

The magnetic gear pump moves liquid through a closed circuit with an external gear set driven magnetically. Circulation duty puts the emphasis on reliable operation over extended periods rather than on peak flow.

Typical circuits are heating, cooling, filtering, mixing, hydrating, degassing, venturi feed and system pressure control, where the pump runs continuously and access for service is limited.

Applications includeingredient dispense, point-of-use dispense, lubrication, sampling, additives, and sample preparation

Key Benefits

Built For Duty That Never Stops

Designed For Long Runs

Circulation applications emphasise reliable operation over extended periods, which is how this build is specified.

Nothing To Leak

No shaft seal means no gland to weep into the equipment it is installed in.

Stable Flow

Gear displacement keeps the circulation rate steady as system conditions change.

Compact Installation

A small head and standard motor frame fit inside machines and cabinets.

Application Scenarios

Where It Is Installed

Temperature Control Loops

Heating and cooling circuits inside equipment where flow must stay constant.

Filtration Circuits

Circulating liquid through a filter at a steady rate rather than in bursts.

Degassing And Conditioning

Hydrating, degassing, venturi feed and system pressure control duties.

Who It Is For

  • Equipment builders with internal liquid circuits
  • Laboratories running conditioning loops
  • Process engineers on small closed circuits
  • Maintenance teams replacing leaking circulation pumps

Problems It Solves

A leaking pump inside a machine

Liquid escaping from a gland inside an enclosure damages far more than the pump. A sealed housing removes that risk.

Circulation rate drifts

Positive displacement keeps the rate tied to speed, not to filter loading or system pressure.

Service access is poor

Fewer wear items means fewer interventions in places that are hard to reach.

Technical Features

How It Is Built

  • Magnetic drive external gear pump
  • Continuous duty circulation build
  • Flow proportional to speed
  • Closed containment housing with no dynamic seal
  • Compact head and motor assembly
  • Suited to heating, cooling, filtering and degassing circuits

Specifications

Technical Data

Circulation duty is defined by flow and circuit resistance. Send both, along with the liquid and its temperature.

Applications includeingredient dispense, point-of-use dispense, lubrication, sampling, additives, and sample preparation

Materials And Process

What Goes Into Every Unit

Materials

  • Stainless steel wetted head
  • PEEK gears available
  • Elastomers selected for the circuit liquid

Manufacturing And Assembly

  • Gear set matched at assembly
  • Magnetic coupling checked
  • Run test on the bench
  • Packing and documentation

Quality Control

  • Leak check of the containment housing
  • Flow verification before dispatch
  • Test record with the order

Customization Options

  • Gear material selection
  • Drive speed and control method
  • Port orientation and mounting
  • Voltage and frequency to suit the machine

Compared With Other Options

SKQB micro pumpSame family. This build is specified around continuous circulation rather than metering accuracy.
Centrifugal circulatorA small centrifugal circulator is cheaper but its flow changes with system resistance and it needs a seal.

Use Guide

Keeping A Circulation Loop Reliable

Filter The Circuit

Install and maintain a filter. Debris is the main cause of wear in a circulating gear pump.

Vent At Commissioning

Remove air from the loop so the pump is not asked to run on gas.

Check Flow Periodically

A slow drop in circulation usually means wear or a blocked filter, not a failed motor.

Plan A Spare

On a critical loop hold a spare head, since replacement is quicker than repair.

Answers

Magnetic Gear Pump FAQ

What circuits is it used in?

Heating, cooling, filtering, mixing, hydrating, degassing, venturi feed and system pressure control.

How long can it run continuously?

Circulation builds are intended for extended periods of operation with clean liquid and a filtered circuit.

Does flow change as a filter blocks?

Very little, because displacement per revolution is fixed. Pressure rises instead, so monitor pressure to spot a blocking filter.

Can it be speed controlled?

Yes. Flow is proportional to speed, so a variable speed drive gives direct control.

Is there a seal to replace?

No dynamic seal at all. The drive is magnetic through a closed housing.

Related Equipment

Related Equipment From The Same Line

Other builds in the magnetic drive micro pump range.

SKQB micro pump with stainless gear head and drive motor

Micro Gear And Magnetic Drive Pumps

SKQB Micro Pump

Magnetic drive micro gear pump for precise low flow duty.

View specifications →
Magnetic drive pump with green motor and stainless pump head

Micro Gear And Magnetic Drive Pumps

Magnetic Pump

Seal free magnetic drive pump for hazardous and volatile liquids.

View specifications →
Compact magnetic drive gear pump with blue motor and stainless head

Micro Gear And Magnetic Drive Pumps

Small Gear Pump

Compact magnetic drive gear pump for machine mounted duty.

View specifications →
Larger magnetic drive gear pump with motor and stainless pump head

Micro Gear And Magnetic Drive Pumps

Macro Pump

Larger magnetic drive gear pump for higher transfer flow.

View specifications →

Need Magnetic Gear Pump Sized For Your Duty Point

Send the circuit flow, the resistance and the liquid, and we will confirm the head and the drive.