Skip to content
Pumps tanks mixers and sanitary fittings built in Wenzhou since 2002

Peristaltic And Dosing Pumps

SK165 Peristaltic Pump

Rollers squeeze a flexible tube, so the liquid touches nothing but the tube and maintenance means fitting a new one.

SK165 peristaltic pump head with tube and rollers

Overview

What This Pump Does

The SK165 peristaltic pump, also called a tube pump, is designed mainly for analytical instruments and feeding equipment. Tube thickness is 1 mm or 1.6 mm, maximum tube size is 4.8 mm, maximum speed is 200 rpm and maximum flow is 165 ml per minute.

It is used in analytical equipment, car wash equipment, food processing, laundry equipment, printing equipment and warewashing equipment, where a simple structure and quick tube changes matter more than high flow.

Thickness of tube1mm and 1.6mm for selection
Maximum of tube4.8mm
Maximum speed200 rpm
Maximum flowrate165ml/min

Key Benefits

What The Tube Principle Gives You

Only The Tube Is Wetted

Chemical compatibility becomes a tube question instead of a whole pump question.

Tubes Change In Minutes

Easy tube replacement means service is a consumable change rather than a pump rebuild.

Quiet And Simple

Low noise and a simple structure suit equipment that sits in a laboratory or a public area.

Self Priming And Dry Run Tolerant

The pump lifts from an empty line and is not damaged when the supply runs out.

Application Scenarios

Where It Is Installed

Analytical Equipment

Feeding sample and reagent streams inside instruments at a repeatable rate.

Washing And Warewashing

Dosing detergent and chemistry in laundry, warewashing and car wash equipment.

Food And Printing Machines

Metering flavour, colour or ink where the liquid must not touch a pump body.

Who It Is For

  • Instrument builders
  • Commercial washing equipment manufacturers
  • Food and printing machine builders
  • Laboratories needing a simple dosing pump

Problems It Solves

Chemicals destroy conventional pumps

With only the tube in contact, aggressive chemistry is handled by choosing the right compound.

Cross contamination between liquids

Changing the tube changes the entire wetted path in minutes.

Pumps fail when a tank empties

Dry running does no damage, which suits intermittent dosing duty.

Technical Features

How It Is Built

  • Tube thickness 1 mm and 1.6 mm for selection
  • Maximum tube size 4.8 mm
  • Maximum speed 200 rpm
  • Maximum flow 165 ml per minute
  • Simple structure with easy tube replacement
  • Low noise operation

Specifications

Technical Data

Published SK165 data. Delivered flow depends on tube bore and speed, so state the rate you need rather than the pump model.

Thickness of tube1mm and 1.6mm for selection
Maximum of tube4.8mm
Maximum speed200 rpm
Maximum flowrate165ml/min

Materials And Process

What Goes Into Every Unit

Materials

  • Flexible tube selected for the chemical
  • Housing suited to bench and machine mounting
  • Rollers matched to the tube size

Manufacturing And Assembly

  • Head assembly and roller setting
  • Tube fitted and flow checked
  • Run test before packing
  • Documentation and spare tube supply

Quality Control

  • Flow verified against the tube fitted
  • Noise and run check before dispatch
  • Test record available with the order

Customization Options

  • Tube material for the chemical
  • Fixed or variable speed drive
  • Mounting for bench, panel or machine
  • Supply voltage to suit the equipment

Compared With Other Options

Magnetic drive gear pumpThe gear pump gives smoother flow at higher pressure on clean liquid. The tube pump wins on aggressive chemistry and dry running.
Diaphragm dosing pumpA diaphragm pump has valves that gas lock. A tube pump passes gas straight through.

Use Guide

Setting Up A Tube Pump

Pick The Tube

Choose bore and compound for the chemical and the rate. A larger tube run slower usually lasts longer.

Route The Lines

Keep suction short and avoid restrictions, which make the tube work harder on every revolution.

Calibrate

Measure delivered volume at the working speed and use that for control.

Change On Schedule

Record tube changes and set an interval from your own evidence rather than waiting for a failure.

Answers

SK165 Peristaltic Pump FAQ

What is the maximum flow?

165 ml per minute at up to 200 rpm, with maximum tube size 4.8 mm.

Which tube thicknesses are available?

1 mm and 1.6 mm for selection.

Where is this pump used?

Analytical equipment, car wash equipment, food processing, laundry equipment, printing equipment and warewashing equipment.

Can it run dry?

Yes, without damage, which is why it suits intermittent dosing.

How often do tubes need changing?

It depends on speed and chemistry. Keep spares on site and set an interval at commissioning.

Related Equipment

Related Equipment From The Same Line

The rest of the tube pump range and the gear pump alternative.

Tube pump head with flexible tube fitted between rollers

Peristaltic And Dosing Pumps

Tube Pump

The SK165 head supplied as a general purpose tube pump.

View specifications →
Peristaltic dosing pump head with tube and drive motor

Peristaltic And Dosing Pumps

Dosing Pump

Peristaltic dosing build of the SK165 for chemical feed.

View specifications →
SKQB micro pump with stainless gear head and drive motor

Micro Gear And Magnetic Drive Pumps

SKQB Micro Pump

Magnetic drive micro gear pump for precise low flow duty.

View specifications →

Need SK165 Peristaltic Pump Sized For Your Duty Point

Send the chemical and the dose rate and we will confirm the tube and the drive.