Skip to content
Pumps tanks mixers and sanitary fittings built in Wenzhou since 2002

Centrifugal Pumps

SKGR Hot Water Pump

Inline mounting for hot water circuits, rated to 120 degrees, so a heating loop does not have to give up floor area.

SKGR vertical hot water pump with inline flanges and motor above

Overview

What This Pump Does

The SKGR is the hot water build of the vertical inline range. It handles pressurised circulation of high temperature water while sitting directly in the pipe run.

Flow runs from 1.5 to 1500 m3/h with head to 150 m, drives to 160 kW and a maximum permissible fluid temperature of 120 degrees Celsius.

Working PrincipleCentrifugal
Main applicationsWater
DriverElectric motor
Power Specs380/415 V 220v , 3phase ; 50hz / 60hz
Max. permissible fluid temperature120°C
Type of connectionFlange

Key Benefits

Hot Circulation In A Small Footprint

120 Degree Rating Inline

Hot water duty without the floor space a horizontal set needs, which suits boiler houses and energy centres.

Fewer Fittings

Straight through flow removes elbows, which matters more on a hot circuit where every fitting is an expansion point.

Seal For Hot Duty

Hard alloy mechanical seal faces or a packing gland, specified with temperature and system pressure in mind.

Material To Suit The Water

Cast iron, stainless steel or bronze wetted parts depending on treatment chemistry.

Application Scenarios

Where It Is Installed

Building And District Heating

Circulating hot water in closed pressurised circuits inside buildings and energy centres.

Process Heating Loops

Feeding jacketed vessels and exchangers with hot water at controlled flow.

Heat Recovery

Moving recovered hot water between source and consumer.

Who It Is For

  • Energy centre and boiler house contractors
  • Process plants with hot water circuits
  • Building services engineers working in tight plant rooms
  • Maintenance teams replacing a failed hot duty pump

Problems It Solves

Standard pumps fail above 80 degrees

A 120 degree rating removes the cause of repeated seal failures on hot circuits.

The plant room is full

Inline mounting means the pump takes pipe length rather than floor area.

Hot circuits punish fittings

Fewer bends and a straight flow path reduce the number of joints on a circuit that expands and contracts daily.

Technical Features

How It Is Built

  • Maximum permissible fluid temperature 120 degrees Celsius
  • Vertical inline installation
  • Mechanical seal with hard alloy faces or packing gland
  • Free passage 0.2 mm, maximum specific gravity 1.1
  • Flanged connections to 500 mm caliber
  • Drives to 160 kW at 380 to 415 V three phase

Specifications

Technical Data

Published SKGR data. On closed circuits, send the system pressure as well as the temperature so the seal arrangement is right.

Working PrincipleCentrifugal
Main applicationsWater
DriverElectric motor
Power Specs380/415 V 220v , 3phase ; 50hz / 60hz
Max. permissible fluid temperature120°C
Type of connectionFlange
Installation positionVertical
Casing/Impeller materialCast iron, Stainless steel/Cast iron, Stainless steel, Bronze
Shaft seal typeMechanical seal; Packing gland
Free passage0.2 mm
Maximum gravity1.1
Maximum drive rating160kW ( 215hp )
Maximum caliber20 inch( 500mm )
Maximum head150m
Flow rate range1.5-1500 m3 /h ( 25-25000 l /m)

Materials And Process

What Goes Into Every Unit

Materials

  • Cast iron casing and impeller
  • Stainless steel option
  • Bronze impeller option
  • Hard alloy seal faces

Manufacturing And Assembly

  • Casting and machining at the works
  • Balanced impeller
  • Hydraulic test before painting
  • Documentation and packing

Quality Control

  • Seal arrangement checked against the stated duty
  • Hydraulic test recorded
  • Factory acceptance test record issued

Customization Options

  • Material selection for treated water
  • Seal type and faces
  • Motor rating and supply
  • Flange standard

Compared With Other Options

SKGS vertical high temperature pumpThe SKGS carries a 240 degree rating for circuits that run above the SKGR limit.
SKWR horizontal hot water pumpSame hot water duty on the horizontal platform, with easier all round access.

Use Guide

Commissioning A Hot Inline Pump

Support The Pipework

Hot pipework moves. Supports and guides must take the weight and the expansion without loading the flanges.

Vent Thoroughly

Air collects at the highest point, often the pump. Vent before start and after every refill.

Raise Temperature Gradually

Bring the circuit up in stages so the casing and seal heat evenly.

Log Hot Running Data

Record flow, pressure and current at working temperature as the baseline.

Answers

SKGR Hot Water Pump FAQ

What temperature is allowed?

Up to 120 degrees Celsius on this model.

What if the circuit runs hotter?

Use the SKGS vertical or SKWS horizontal models, rated to 240 degrees.

Can I use it for thermal oil?

No. Thermal oil circuits should use the magnetic drive heat transfer line rated to 350 degrees.

Does it need a baseplate?

No, it is carried by the pipework, which must be supported either side of the pump.

What flow can it cover?

1.5 to 1500 m3/h with head to 150 m.

Related Equipment

Related Equipment From The Same Line

Hot duty options across the vertical and horizontal ranges.

Hot oil pump head coupled to a motor on a machine frame

High Temperature Pumps

Hot Oil Pump

Magnetic drive heat transfer pump for hot oil and hot water to 350 degrees.

View specifications →

Need SKGR Hot Water Pump Sized For Your Duty Point

Send circuit temperature, system pressure and flow, and the model and seal come back together.