SC/APC Pigtail (Ref 352)
SC/APC Pigtail (Ref 352) is part of the various pigtail range built by Ever Expresslink Limited in Ningbo, China. It is built on the SC (Subscriber Connector) interface.
Pre-terminated tails that put the factory end face inside your splice tray
Interested in SC/APC Pigtail (Ref 352)
Email the model and quantity with your destination country. We reply with pricing, lead time and a datasheet.
Product Overview
SC/APC Pigtail (Ref 352) is part of the various pigtail range built by Ever Expresslink Limited in Ningbo, China. It is built on the SC (Subscriber Connector) interface.
SC pairs a 2.5 mm ferrule with a square push-pull housing that clicks into the adapter and releases by pulling the body straight back. SC bodies clip together into duplex pairs. Check polarity before you clip, because a reversed duplex clip is easy to build and hard to spot in a cabinet.
APC puts an 8-degree angle on the end face so that reflected light is thrown into the cladding instead of back down the core. Specify APC on PON, RF-over-glass and CATV paths where back-reflection has to be pushed as low as possible. Green housing marks it.
Key Benefits
- Supplied as SC/APC Pigtail (Ref 352), so the part you receive matches the designation you ordered against
- APC end face: Specify APC on PON, RF-over-glass and CATV paths where back-reflection has to be pushed as low as possible. Green housing marks it.
- Tail lengths chosen for the enclosure so routing stays inside the bend radius
- Connector end face made and tested under factory conditions
- Field work reduced to a fusion splice, which the splicer measures for you
- Bundle versions load a twelve-fiber tray in one pass
Problems It Solves
- Pigtail tails too short to route properly inside a closure, forcing tight bends
- Mismatched polish between the pigtail and the distribution frame
- Field-terminated connectors whose loss varies with the weather and the technician
- Splice trays loaded one fiber at a time when a bundle would do it in a single operation
Application Scenarios
- ODF patch fields
- Loading 12-fiber trays in a rack-mounted ODF
- Splicing subscriber drops inside an FTTH termination box
- Building custom terminal boxes on an assembly bench
- Emergency restoration of a damaged distribution cable
Who It Is For
- ODF and patch panel builders loading splice trays at scale
- Central office teams splicing onto backbone cable
- Maintenance crews carrying repair kits for emergency restoration
- Assembly houses building their own boxes and terminal units
Technical Features
- SC (Subscriber Connector) interface
- SC bodies clip together into duplex pairs. Check polarity before you clip, because a reversed duplex clip is easy to build and hard to spot in a cabinet.
- Factory-polished ferrule with inspected end face
- 900 µm tight buffer or 250 µm bare fiber tail depending on the tray
- Color-coded buffer following standard fiber identification order
- Bundle and fan-out versions for multi-fiber trays
Materials
- Zirconia ceramic ferrule
- 900 µm tight-buffered fiber or bare fiber tail
- Aramid yarn reinforcement where the design carries load
- Thermoplastic boot and housing
- Furcation tubing on bundle versions
Specifications
| Product Designation | SC/APC pigtail |
|---|---|
| Product Family | Various Pigtail |
| Connector Interface | SC (Subscriber Connector) |
| End Face Polish | APC |
| Manufactured In | Ningbo, China |
| Warranty | One year against defects in materials and workmanship |
Values shown are those carried by the product designation. Dimensional and optical values for a specific order are confirmed on the quotation.
Manufacturing Process
- Fiber kitting and buffer color verification
- Connector assembly, epoxy cure and polish
- End-face inspection and loss measurement
- Tail cutting to the ordered length and buffer stripping preparation
- Bundling and furcation for multi-fiber versions
- Coiling, labeling and individual packing
Quality Control
- End-face geometry and cleanliness inspection on every connector
- Insertion loss and return loss measurement before packing
- Buffer color sequence verified against the order for bundles
- Tail length verified against the works order
- Waterproof versions pressure-checked on a sample basis
Customization Options
- Tail length matched to the enclosure you are loading
- Simplex, bundle, fan-out and waterproof formats
- UPC or APC polish
- Buffer color sequence to your own convention
- Ribbon-compatible versions for mass fusion splicing
Compared With Other Options
| LC | LC is half the footprint and doubles port density; SC is easier to handle in a crowded closure |
|---|---|
| FC | FC's threaded nut resists vibration; SC is faster to patch and re-patch |
| UPC version | UPC uses a domed end face for direct core contact and suits general data and enterprise work. Specify APC where back reflection is a limiting factor. |
Handling SC/APC Pigtail (Ref 352)
Before You Order
- Check buffer color against the tray plan before stripping anything
- Strip, clean and cleave to the splicer's stated dimensions
- Fusion splice and record the splicer's loss estimate
In Service
- Protect the splice with a heat-shrink sleeve and seat it in the tray
- Coil the tail inside the tray without dropping below the fiber's bend radius
- Cap the connector until the frame side is ready to be patched
Questions About SC/APC Pigtail (Ref 352)
What do you need from us to quote SC/APC Pigtail (Ref 352)?
The quantity, the destination and anything that has to match on your side: connector and polish at each end, fiber mode and core size, and length where the item is an assembly. If you are matching a part you already buy, send the sample and we will quote against it.
Can SC/APC Pigtail (Ref 352) be supplied with a different connector interface?
Yes. SC (Subscriber Connector) is what this designation carries, and the same family is stocked across the other mainstream connector standards. Tell us the port you have to mate with and we will confirm the equivalent part.
Are waterproof pigtails available for outdoor enclosures?
Yes, we supply waterproof pigtail versions intended for direct entry into outdoor closures and pedestals. Confirm the gland and enclosure type on your inquiry.
Why use a pigtail instead of terminating the cable directly?
Because a factory-made end face is more repeatable than one polished in a closure. Splicing a pigtail on moves the difficult step indoors and leaves the field crew a fusion splice whose loss the machine reports.
What tail length should I order?
Long enough to route around the inside of your closure or tray without tight bends, and no longer. Tell us the enclosure you are loading and we will suggest a length that coils cleanly.
More Various Pigtail

Bundle Pigtail
Bundle. Used for building custom terminal boxes on an assembly bench.
View Details
MTP-LC (Ref 356)
Used for emergency restoration of a damaged distribution cable.
View Details
Waterproof Pigtails
Used for building custom terminal boxes on an assembly bench.
View Details
Breakout Kit/Fanout Kit
Fanout. Used for emergency restoration of a damaged distribution cable.
View DetailsGuides Cases and Industries
Choosing Between Dome and Horizontal Splice Closures
Cable geometry decides the format, capacity decides the size, and the reopening method decides what the next crew has to carry.
Comparison ArticleODF Terminal Box and FTTH Termination Box Compared
Three enclosures that all hold fiber and adapters, separated by where they sit in the network and who opens them.
Troubleshooting ArticlePower Meter and OTDR Testing Basics
Two instruments that answer different questions, why you need both, and what to write down so the result means something later.
Deployment ProfilePON Street Cabinet Split Point
How a feeder fiber becomes subscriber ports inside a street cabinet, and which decisions are expensive to reverse
Deployment ProfileMDU Riser Fiber Distribution
Distributing fiber up an apartment riser so units can be connected one at a time without disturbing the rest
IndustryTelecom and Carrier Networks
Passive components for access, metro and transmission plant that has to stay up for decades
IndustryFTTH and Broadband Operators
Drop-side and distribution hardware for networks whose cost is decided per subscriber
Request Pricing For SC/APC Pigtail (Ref 352)
Tell us the quantity and destination. If you are matching a part you already buy, send the sample and we will quote against it.