
SC Bare Adapter
SC Bare Adapter is part of the bare adapter range built by Ever Expresslink Limited in Ningbo, China. It is built on the SC (Subscriber Connector) interface.
Temporary connections to unterminated fiber for test and splice verification
Interested in SC Bare Adapter
Email the model and quantity with your destination country. We reply with pricing, lead time and a datasheet.
Product Overview
SC Bare Adapter is part of the bare adapter range built by Ever Expresslink Limited in Ningbo, China. It is built on the SC (Subscriber Connector) interface.
It is the workhorse of FTTH and passive optical distribution: a technician can seat a port blind, inside a closure, wearing gloves, without rotating anything. SC bodies clip together into duplex pairs. Check polarity before you clip, because a reversed duplex clip is easy to build and hard to spot in a cabinet.
It is one of 7 items in this range. A typical application is fiber training and practical assessment. What the range is built to give you there: reusable across many fibres in a single session.
The problem it addresses is terminating a fiber purely to verify continuity, then cutting the connector off. A practical note that applies across this range: clean the guide bore between fibres. Specifications for a particular configuration are confirmed on the quotation rather than assumed from the designation.
Key Benefits
- Supplied as SC Bare Adapter, so the part you receive matches the designation you ordered against
- Compact enough to live in a splicing kit
- Square and standard body versions for different panel and bench mounts
- Measure without spending a connector and a termination cycle
- Reusable across many fibres in a single session
Problems It Solves
- Slow fault-finding on a partly built link
- Damaged fiber from improvised clamping methods
- Test kits that cannot reach bare fiber in a splice tray
- Needing a measurement on fiber that has not been terminated yet
Application Scenarios
- FTTH terminal boxes and splice closures
- Fiber training and practical assessment
- Continuity checking before a splice closure is sealed
- Power measurement on an unterminated distribution cable
- Laboratory characterisation of fiber samples
Who It Is For
- Laboratories characterizing fiber samples
- Training programs teaching splice verification
- Maintenance teams fault-finding on a partly built link
- Splicing crews verifying continuity before closing a tray
Technical Features
- SC (Subscriber Connector) interface
- SC bodies clip together into duplex pairs. Check polarity before you clip, because a reversed duplex clip is easy to build and hard to spot in a cabinet.
- Clamping mechanism sized for 250 µm or 900 µm fiber
- Standard connector interface on the test-set side
- Reusable clamp designed for repeated insertion
- Available for SC, FC, ST and LC port types
Materials
- Zirconia ceramic or precision metal guide
- Metal or thermoplastic body
- Spring clamping mechanism
- Thermoplastic dust cap
Specifications
| Product Designation | SC bare adapter |
|---|---|
| Product Family | Bare Adapter |
| Connector Interface | SC (Subscriber Connector) |
| Manufactured In | Ningbo, China |
| Warranty | One year against defects in materials and workmanship |
Values shown are those carried by the product designation. Dimensional and optical values for a specific order are confirmed on the quotation.
Manufacturing Process
- Guide bore inspection
- Clamp mechanism assembly and force setting
- Mating interface verification
- Repeat-insertion durability sampling
- Cleaning and packing
Quality Control
- Guide bore concentricity sampled per lot
- Clamping force verified on sample units
- Repeat-insertion cycling on samples
- Loss repeatability measured with a reference fiber
- Visual inspection of the mating interface
Customization Options
- Connector interface type
- 250 µm or 900 µm fiber acceptance
- Square or standard body
- Kitted with cleaver and cleaning consumables
Compared With Other Options
| LC | LC is half the footprint and doubles port density; SC is easier to handle in a crowded closure |
|---|---|
| FC | FC's threaded nut resists vibration; SC is faster to patch and re-patch |
Handling SC Bare Adapter
Before You Order
- Cleave the fiber square with a precision cleaver before insertion
- Clean the fiber with lint-free wipe and solvent
- Insert to the stop and close the clamp without forcing it
In Service
- Treat the reading as indicative rather than as a certified link measurement
- Release the clamp before withdrawing the fiber to avoid scoring it
- Clean the guide bore between fibres
Questions About SC Bare Adapter
What do you need from us to quote SC Bare Adapter?
The quantity, the destination and anything that has to match on your side: connector and polish at each end, fiber mode and core size, and length where the item is an assembly. If you are matching a part you already buy, send the sample and we will quote against it.
Can SC Bare Adapter be supplied with a different connector interface?
Yes. SC (Subscriber Connector) is what this designation carries, and the same family is stocked across the other mainstream connector standards. Tell us the port you have to mate with and we will confirm the equivalent part.
Do I still need to cleave the fiber?
Yes. The adapter aligns the fiber but cannot fix a bad cleave. A square, clean cleave is what makes the reading meaningful.
What fiber sizes does a bare adapter accept?
Versions are available for 250 µm coated fiber and for 900 µm tight-buffered fiber. Confirm which one your splice tray presents before ordering.
Is a bare adapter measurement as accurate as a terminated one?
It is repeatable enough for continuity and relative loss checks, which is what a splicing crew needs. For certified link measurements, terminate properly or use a reference-grade test cord.
More Bare Adapter

ST Bare Adapter (Ref 343)
Used for laboratory characterisation of fiber samples.
View Details
FC Square Bare Adapter
Used for power measurement on an unterminated distribution cable.
View Details
LC Square Bare Adapter
Used for power measurement on an unterminated distribution cable.
View Details
SC Square Bare Adapter
Used for fault localisation during a restoration.
View DetailsGuides Cases and Industries
Power Meter and OTDR Testing Basics
Two instruments that answer different questions, why you need both, and what to write down so the result means something later.
Product GuideWhat a Hybrid Fiber Adapter Does and When to Use One
Joining two different connector standards without cutting anything, and the three things that still have to match.
Deployment ProfileCampus Backbone Connector Migration
Phasing a legacy ST or FC estate onto SC and LC equipment without cutting anything
IndustryTest Measurement and OEM Integration
Component-level supply for instrument builders and cable assembly houses
Request Pricing For SC Bare Adapter
Tell us the quantity and destination. If you are matching a part you already buy, send the sample and we will quote against it.