
LC Square Bare Adapter
LC Square Bare Adapter is part of the bare adapter range built by Ever Expresslink Limited in Ningbo, China. It is built on the LC (Lucent Connector) interface.
Temporary connections to unterminated fiber for test and splice verification
Interested in LC Square Bare Adapter
Email the model and quantity with your destination country. We reply with pricing, lead time and a datasheet.
Product Overview
LC Square Bare Adapter is part of the bare adapter range built by Ever Expresslink Limited in Ningbo, China. It is built on the LC (Lucent Connector) interface.
Small form-factor transceivers are built around it, so LC is what a data-center or an access switch presents to you whether you wanted it or not. The latch is small and breaks if the cord is pulled sideways out of a dense panel. Use a boot or a push-pull tab on panels packed to 48 ports and above.
It is one of 7 items in this range. A typical application is laboratory characterisation of fiber samples. What the range is built to give you there: square and standard body versions for different panel and bench mounts.
The problem it addresses is slow fault-finding on a partly built link. A practical note that applies across this range: cleave the fiber square with a precision cleaver before insertion. Specifications for a particular configuration are confirmed on the quotation rather than assumed from the designation.
Key Benefits
- Supplied as LC Square Bare Adapter, so the part you receive matches the designation you ordered against
- Compact enough to live in a splicing kit
- Square and standard body versions for different panel and bench mounts
- Measure without spending a connector and a termination cycle
- Reusable across many fibres in a single session
Problems It Solves
- Test kits that cannot reach bare fiber in a splice tray
- Needing a measurement on fiber that has not been terminated yet
- Terminating a fiber purely to verify continuity, then cutting the connector off
- Slow fault-finding on a partly built link
Application Scenarios
- Enterprise switch uplinks
- Continuity checking before a splice closure is sealed
- Power measurement on an unterminated distribution cable
- Laboratory characterisation of fiber samples
- Fault localisation during a restoration
Who It Is For
- Test engineers measuring unterminated cable
- Laboratories characterizing fiber samples
- Training programs teaching splice verification
- Maintenance teams fault-finding on a partly built link
Technical Features
- LC (Lucent Connector) interface
- The latch is small and breaks if the cord is pulled sideways out of a dense panel. Use a boot or a push-pull tab on panels packed to 48 ports and above.
- Available for SC, FC, ST and LC port types
- Square-body versions for panel mounting
- Clamping mechanism sized for 250 µm or 900 µm fiber
- Standard connector interface on the test-set side
Materials
- Zirconia ceramic or precision metal guide
- Metal or thermoplastic body
- Spring clamping mechanism
- Thermoplastic dust cap
Specifications
| Product Designation | LC square bare adapter |
|---|---|
| Product Family | Bare Adapter |
| Connector Interface | LC (Lucent Connector) |
| Manufactured In | Ningbo, China |
| Warranty | One year against defects in materials and workmanship |
Values shown are those carried by the product designation. Dimensional and optical values for a specific order are confirmed on the quotation.
Manufacturing Process
- Guide bore inspection
- Clamp mechanism assembly and force setting
- Mating interface verification
- Repeat-insertion durability sampling
- Cleaning and packing
Quality Control
- Guide bore concentricity sampled per lot
- Clamping force verified on sample units
- Repeat-insertion cycling on samples
- Loss repeatability measured with a reference fiber
- Visual inspection of the mating interface
Customization Options
- Connector interface type
- 250 µm or 900 µm fiber acceptance
- Square or standard body
- Kitted with cleaver and cleaning consumables
Compared With Other Options
| SC | SC is more forgiving to handle; LC fits twice the ports per rack unit |
|---|---|
| MTRJ | MTRJ carries a duplex pair in one ferrule; LC keeps the two fibres separately serviceable |
Handling LC Square Bare Adapter
Before You Order
- Cleave the fiber square with a precision cleaver before insertion
- Clean the fiber with lint-free wipe and solvent
- Insert to the stop and close the clamp without forcing it
In Service
- Treat the reading as indicative rather than as a certified link measurement
- Release the clamp before withdrawing the fiber to avoid scoring it
- Clean the guide bore between fibres
Questions About LC Square Bare Adapter
What do you need from us to quote LC Square Bare Adapter?
The quantity, the destination and anything that has to match on your side: connector and polish at each end, fiber mode and core size, and length where the item is an assembly. If you are matching a part you already buy, send the sample and we will quote against it.
Can LC Square Bare Adapter be supplied with a different connector interface?
Yes. LC (Lucent Connector) is what this designation carries, and the same family is stocked across the other mainstream connector standards. Tell us the port you have to mate with and we will confirm the equivalent part.
Is a bare adapter measurement as accurate as a terminated one?
It is repeatable enough for continuity and relative loss checks, which is what a splicing crew needs. For certified link measurements, terminate properly or use a reference-grade test cord.
How many times can one adapter be reused?
They are designed for repeated insertion across a working session and beyond. Replace when the clamp no longer holds the fiber firmly or the guide bore shows wear.
Which connector types are available?
SC, FC, ST and LC interfaces are the common ones, in both standard and square-body form. Tell us your test set's port type and we will match it.
More Bare Adapter

SC Bare Adapter
Used for power measurement on an unterminated distribution cable.
View Details
ST Bare Adapter (Ref 429)
Used for fiber training and practical assessment.
View Details
FC Bare Adapter
Used for power measurement on an unterminated distribution cable.
View Details
ST Bare Adapter (Ref 343)
Used for laboratory characterisation of fiber samples.
View DetailsGuides Cases and Industries
Power Meter and OTDR Testing Basics
Two instruments that answer different questions, why you need both, and what to write down so the result means something later.
Product GuideWhat a Hybrid Fiber Adapter Does and When to Use One
Joining two different connector standards without cutting anything, and the three things that still have to match.
Deployment ProfileCampus Backbone Connector Migration
Phasing a legacy ST or FC estate onto SC and LC equipment without cutting anything
IndustryTest Measurement and OEM Integration
Component-level supply for instrument builders and cable assembly houses
Request Pricing For LC Square Bare Adapter
Tell us the quantity and destination. If you are matching a part you already buy, send the sample and we will quote against it.