
ST Bare Adapter (Ref 343)
ST Bare Adapter (Ref 343) is part of the bare adapter range built by Ever Expresslink Limited in Ningbo, China. It is built on the ST (Straight Tip) interface.
Temporary connections to unterminated fiber for test and splice verification
Interested in ST Bare Adapter (Ref 343)
Email the model and quantity with your destination country. We reply with pricing, lead time and a datasheet.
Product Overview
ST Bare Adapter (Ref 343) is part of the bare adapter range built by Ever Expresslink Limited in Ningbo, China. It is built on the ST (Straight Tip) interface.
It remains common in installed multimode building backbones and in industrial or campus networks that were cabled before SC and LC took over. The bayonet pin has to clear the slot fully. A partially rotated ST looks seated but sits off the reference plane and reads high loss.
It is one of 7 items in this range. A typical application is continuity checking before a splice closure is sealed. What the range is built to give you there: available for the main connector port types and both ferrule sizes.
The problem it addresses is test kits that cannot reach bare fiber in a splice tray. A practical note that applies across this range: release the clamp before withdrawing the fiber to avoid scoring it. Specifications for a particular configuration are confirmed on the quotation rather than assumed from the designation.
Key Benefits
- Supplied as ST Bare Adapter (Ref 343), so the part you receive matches the designation you ordered against
- Available for the main connector port types and both ferrule sizes
- Compact enough to live in a splicing kit
- Square and standard body versions for different panel and bench mounts
- Measure without spending a connector and a termination cycle
Problems It Solves
- Slow fault-finding on a partly built link
- Damaged fiber from improvised clamping methods
- Test kits that cannot reach bare fiber in a splice tray
- Needing a measurement on fiber that has not been terminated yet
Application Scenarios
- Campus and industrial LAN risers
- Fault localisation during a restoration
- Fiber training and practical assessment
- Continuity checking before a splice closure is sealed
- Power measurement on an unterminated distribution cable
Who It Is For
- Maintenance teams fault-finding on a partly built link
- Splicing crews verifying continuity before closing a tray
- Test engineers measuring unterminated cable
- Laboratories characterizing fiber samples
Technical Features
- ST (Straight Tip) interface
- The bayonet pin has to clear the slot fully. A partially rotated ST looks seated but sits off the reference plane and reads high loss.
- Clamping mechanism sized for 250 µm or 900 µm fiber
- Standard connector interface on the test-set side
- Reusable clamp designed for repeated insertion
- Available for SC, FC, ST and LC port types
Materials
- Zirconia ceramic or precision metal guide
- Metal or thermoplastic body
- Spring clamping mechanism
- Thermoplastic dust cap
Specifications
| Product Designation | ST bare adapter |
|---|---|
| Product Family | Bare Adapter |
| Connector Interface | ST (Straight Tip) |
| Manufactured In | Ningbo, China |
| Warranty | One year against defects in materials and workmanship |
Values shown are those carried by the product designation. Dimensional and optical values for a specific order are confirmed on the quotation.
Manufacturing Process
- Guide bore inspection
- Clamp mechanism assembly and force setting
- Mating interface verification
- Repeat-insertion durability sampling
- Cleaning and packing
Quality Control
- Guide bore concentricity sampled per lot
- Clamping force verified on sample units
- Repeat-insertion cycling on samples
- Loss repeatability measured with a reference fiber
- Visual inspection of the mating interface
Customization Options
- Connector interface type
- 250 µm or 900 µm fiber acceptance
- Square or standard body
- Kitted with cleaver and cleaning consumables
Compared With Other Options
| SC | SC pushes straight in; ST needs a twist but is quick once the technique is habitual |
|---|---|
| FC | Both use a 2.5 mm ferrule; FC screws down for vibration, ST trades that for speed |
Handling ST Bare Adapter (Ref 343)
Before You Order
- Cleave the fiber square with a precision cleaver before insertion
- Clean the fiber with lint-free wipe and solvent
- Insert to the stop and close the clamp without forcing it
In Service
- Treat the reading as indicative rather than as a certified link measurement
- Release the clamp before withdrawing the fiber to avoid scoring it
- Clean the guide bore between fibres
Questions About ST Bare Adapter (Ref 343)
What do you need from us to quote ST Bare Adapter (Ref 343)?
The quantity, the destination and anything that has to match on your side: connector and polish at each end, fiber mode and core size, and length where the item is an assembly. If you are matching a part you already buy, send the sample and we will quote against it.
Can ST Bare Adapter (Ref 343) be supplied with a different connector interface?
Yes. ST (Straight Tip) is what this designation carries, and the same family is stocked across the other mainstream connector standards. Tell us the port you have to mate with and we will confirm the equivalent part.
Which connector types are available?
SC, FC, ST and LC interfaces are the common ones, in both standard and square-body form. Tell us your test set's port type and we will match it.
Do I still need to cleave the fiber?
Yes. The adapter aligns the fiber but cannot fix a bad cleave. A square, clean cleave is what makes the reading meaningful.
What fiber sizes does a bare adapter accept?
Versions are available for 250 µm coated fiber and for 900 µm tight-buffered fiber. Confirm which one your splice tray presents before ordering.
More Bare Adapter

SC Bare Adapter
Used for power measurement on an unterminated distribution cable.
View Details
ST Bare Adapter (Ref 429)
Used for fiber training and practical assessment.
View Details
FC Bare Adapter
Used for power measurement on an unterminated distribution cable.
View Details
FC Square Bare Adapter
Used for power measurement on an unterminated distribution cable.
View DetailsGuides Cases and Industries
Power Meter and OTDR Testing Basics
Two instruments that answer different questions, why you need both, and what to write down so the result means something later.
Product GuideWhat a Hybrid Fiber Adapter Does and When to Use One
Joining two different connector standards without cutting anything, and the three things that still have to match.
Deployment ProfileCampus Backbone Connector Migration
Phasing a legacy ST or FC estate onto SC and LC equipment without cutting anything
IndustryTest Measurement and OEM Integration
Component-level supply for instrument builders and cable assembly houses
Request Pricing For ST Bare Adapter (Ref 343)
Tell us the quantity and destination. If you are matching a part you already buy, send the sample and we will quote against it.