Skip to content
Pumps tanks mixers and sanitary fittings built in Wenzhou since 2002

Micro Gear And Magnetic Drive Pumps

Small Gear Pump

The compact build of the micro gear family, sized to fit inside equipment rather than to stand beside it.

Compact magnetic drive gear pump with blue motor and stainless head

Overview

What This Pump Does

The small gear pump is the compact member of the magnetic drive micro pump range. It is used where the pump has to be built into a machine, a cabinet or a bench instrument and still deliver a repeatable low flow.

Duties include lubrication feed, additive dosing, coating and adhesive supply and sample preparation, all of which need a small pump that delivers the same volume every revolution.

Applications includeingredient dispense, point-of-use dispense, lubrication, sampling, additives, and sample preparation

Key Benefits

Why It Fits Where Others Do Not

Small Installed Envelope

A compact head and motor make it practical to mount inside equipment without redesigning the frame.

No Seal To Service

Magnetic drive removes the gland, which is important when the pump is buried inside a machine.

Repeatable Volume

Fixed displacement per revolution keeps dosing consistent across production runs.

Material Options

PEEK gears where the liquid rules out metal to metal contact.

Application Scenarios

Where It Is Installed

Machine Lubrication

Feeding a measured lubricant stream to bearings and slides inside a machine.

Coating And Adhesive Feed

Supplying coatings, adhesives and solvents to an application head at a controlled rate.

Bench Instruments

Sample preparation and point of use dispense inside laboratory equipment.

Who It Is For

  • Machine builders needing an internal pump
  • Laboratory instrument manufacturers
  • Production engineers automating lubricant or adhesive feed
  • Integrators working in tight enclosures

Problems It Solves

No room for a standard pump

The compact assembly fits where a conventional sealed pump and its service clearance would not.

Maintenance inside a machine

Removing the seal removes the reason to open the machine on a schedule.

Inconsistent dosing between runs

Positive displacement makes the delivered volume a function of revolutions, which a controller can count.

Technical Features

How It Is Built

  • Compact magnetic drive gear pump assembly
  • Positive displacement low flow delivery
  • No shaft seal
  • PEEK gear option
  • Mountable inside machines and cabinets
  • Speed controlled flow

Specifications

Technical Data

Send the available envelope as well as the duty. On machine mounted pumps the space is often the binding constraint.

Applications includeingredient dispense, point-of-use dispense, lubrication, sampling, additives, and sample preparation
ModelMax SpeedFlowratePressureFrequencyPort size
r/minL/minMPaHZinch
SKQB82900rpm / 3300rpm3 L0.250Hz /60Hz1/8”
SKQB105 L0.251/8”
SKQB1515 L0.33/8”
SKQB2020 L0.43/8”

Materials And Process

What Goes Into Every Unit

Materials

  • Stainless steel head
  • PEEK gears where required
  • Elastomers matched to the liquid

Manufacturing And Assembly

  • Gear matching and assembly
  • Coupling fitted and checked
  • Bench run test
  • Packing and documentation

Quality Control

  • Dimensional check against the mounting requirement
  • Flow verified before dispatch
  • Test record supplied with the order

Customization Options

  • Port orientation for the installation
  • Gear material
  • Motor and drive selection
  • Cable and connector arrangement

Compared With Other Options

SKQB micro pumpSame principle in a larger frame. Choose this build when space rather than flow is the limit.
Peristaltic pumpA tube pump is simpler and tolerates dry running, but needs tube changes and gives pulsing flow.

Use Guide

Building The Pump Into A Machine

Confirm The Envelope

Check head, motor and connection clearances against the frame before finalising the design.

Plan Access

Leave enough room to disconnect the ports, even though the pump has no seal to service.

Filter And Protect

Fit a suction filter and protect against dry running in the machine control logic.

Calibrate In Place

Measure delivered volume per revolution on the installed liquid and store that figure in the controller.

Answers

Small Gear Pump FAQ

How small is it?

It is the compact build of the family. Send the available space with your enquiry and we will confirm the dimensions of the head and motor.

Can it dose adhesives?

Metering applications include adhesives, coatings, lubricants and solvents. Confirm the specific product for gear material selection.

Is dry running acceptable?

No. Protect against an empty suction line in the machine control.

Can the controller count volume?

Yes. Displacement per revolution is fixed, so counted revolutions give a dosed volume once calibrated.

Are PEEK gears available on this build?

Yes, where the liquid or the application rules out metal gears.

Related Equipment

Related Equipment From The Same Line

Other small pumps used inside equipment.

SKQB micro pump with stainless gear head and drive motor

Micro Gear And Magnetic Drive Pumps

SKQB Micro Pump

Magnetic drive micro gear pump for precise low flow duty.

View specifications →
Magnetic gear pump with blue motor and stainless gear head

Micro Gear And Magnetic Drive Pumps

Magnetic Gear Pump

Magnetic drive gear pump for continuous circulation loops.

View specifications →
Larger magnetic drive gear pump with motor and stainless pump head

Micro Gear And Magnetic Drive Pumps

Macro Pump

Larger magnetic drive gear pump for higher transfer flow.

View specifications →

Need Small Gear Pump Sized For Your Duty Point

Send the duty and the space you have. The envelope usually decides the build before the flow does.