Sterilization equipment for clinics that reprocess on site
Joident Novo Pro 23L LED steam sterilizer

Novo Pro 23L LED Steam Sterilizer

The Novo Pro 23L LED is a Class B steam sterilizer designed for small to mid-size dental clinics and medical practices that need to sterilize wrapped and hollow instruments in a compact repr.

Overview

What The Novo Pro 23L LED Is For

The Novo Pro 23L LED is a Class B steam sterilizer designed for small to mid-size dental clinics and medical practices that need to sterilize wrapped and hollow instruments in a compact reprocessing space. A 23 L chamber fits up to five trays, and the machine uses a fractionated vacuum cycle to ensure steam reaches all surfaces. It operates on single-phase 230 V and occupies 685 x 438 mm of bench space, making it suitable for back rooms with limited floor area. The LED interface simplifies operation with only three clicks to start a cycle, and every cycle is recorded to SD card or thermal printer for compliance.

60+Countries with users
8Patented technologies
1800Days of aging test
Key Benefits

Why Clinics Choose The Novo Pro 23L LED

Class B fractionated vacuum sterilization processes wrapped instruments and hollow loads, not only unwrapped solids

Up to five trays per load reduces the number of cycles needed between patients

Three-click automatic cycle start with no manual intervention required during operation

Preheating with standby maintains chamber temperature between cycles, reducing time for the next load

Intelligent monitoring and diagnosis identifies the failing section and shows the fault message and solution on screen

Cycle data is traceable via SD card or thermal printer, supporting compliance audits without manual logging

Application Scenarios

  • Sterilizing wrapped handpieces and instruments between patients in a two to four chair dental practice
  • Processing hollow instruments where air trapped in the lumen would prevent effective sterilization
  • Running a full day’s instrument load with wrapped surgical kits and porous items in one cycle
  • Maintaining compliance records for an inspection by storing cycle data on removable media
  • Using the preheating system to reduce cycle time during peak clinic hours when the schedule is full

Who It Is For

  • Dental clinics and stomatology departments reprocessing instruments on site between patients
  • Small hospitals and outpatient practices without a central sterile services department
  • Aesthetic and cosmetic clinics that sterilize reusable cannulas and instrument sets
  • Veterinary practices sterilizing surgical packs in house
  • Dental equipment distributors who need a Class B model with documented conformity for their catalogue
Problems It Solves

What Goes Wrong Without It

  • Unwrapped only sterilizers cannot process pouched or hollow loads, which limits what a practice can offer
  • Manual cycle logging is error-prone and fails inspection; the Novo Pro 23L LED records every cycle automatically
  • Cold starts make the first cycles of the day the slowest, exactly when the schedule is fullest
  • Instruments coming out damp have to be reprocessed, which wastes a cycle and a working half hour
  • Tap water scales the chamber and the boiler and shortens the life of the machine
Joident Novo Pro 23L LED steam sterilizer, view 6
Technical

Technical Features And Specifications

  • Fractionated vacuum Class B cycles conforming to EN 13060
  • 3.4 L transparent clean water tank with visible level indicator for easy monitoring
  • Preheating system with standby that maintains minimum chamber temperature between cycles
  • Wind cooling super window with 260 x 142 mm cooling area, 73 aluminium radiating layers, and 18 radiating pipes
  • Quick coupling connections on the front for filling and draining, with optional automatic filling system
  • Intelligent monitoring and diagnosis that identifies the failing section and shows the fault message and solution
  • Traceability to SD card or thermal printer (built-in or external), with automatic data logging
  • Bacteriological filter retaining not less than 99.5 percent of particles above 0.3 micrometres
  • Double safety door locking combining a mechanical lock, sensor switch, and pressure lock
  • Optional built-in water quality detection to prevent poor feed water from reaching the boiler
Novo Pro 23L LED specifications
Cycle TypeClass B, fractionated vacuum
Chamber Volume23 L
Chamber Dimensionsdiameter 245 mm x 445 mm
Overall Size (L x W x H)685 x 438 x 405 mm
Weightapprox. 50 kg
Electrical Supply200-240 Vac, 50/60 Hz, single phase
Nominal Voltage230 Vac / 50 Hz
Power1700 W
Fuse10 A
Max Working Pressure2.5 bar (250 kPa)
Min Working Pressure-0.9 bar (-90 kPa)
Pressure Safety Valve2.45 bar (245 kPa)
Vacuumbetter than -0.8 bar (-80 kPa)
Max Temperaturebelow 145 C
Clean Water Tankapprox. 3.4 L
Waste Water Tankapprox. 1.7 L
Water Shortage Alarmbelow 0.5 L
Water Consumption Per Cycle0.17 L min to 0.31 L max
Feed Water QualityEN 13060 Annex C, conductivity below 5 microsiemens per cm
Steel Wire Carrier410 x 205 x 200 mm
Aluminium Tray380 x 193 x 16 mm
Tray Capacityup to 5 trays, or 3 trays rotated 90 degrees
Bacteriological Filternot less than 99.5 percent for particles above 0.3 micrometres
Ambient Temperature+5 C to +40 C, ideal range 16-26 C
Humidity Limitmax 80 percent at 31 C, falling linearly to 50 percent at 40 C
Max Altitude3500 m above sea level
Sound Power Levelbelow 70 dB
ConformityEN 13060, IEC 61010-1, IEC 61010-2-040, EN 61326

Materials

  • Stainless steel sterilization chamber
  • Steel wire tray carrier
  • Aluminium instrument trays
  • Aluminium finned heat exchanger for the cooling window

How It Is Used In The Workflow

  • Load preparation - instruments are cleaned in an ultrasonic cleaner and dried before wrapping
  • Wrapping - pouches or reels are sealed on a thermal sealer with the cycle date visible
  • Water supply - the tank is filled with distilled water below 5 microsiemens per cm
  • Cycle selection - the operator selects one of the 11 programs and tests on the LED interface
  • Fractionated vacuum - repeated vacuum and steam pulses remove air from wrapped and hollow loads
  • Sterilization and drying - the cycle holds temperature, then dries, with extra drying available
  • Record - the cycle is written to SD card or thermal printer and stored for compliance

Quality Control

  • Vacuum and pressure limits are monitored on every cycle and the cycle aborts if a limit is missed
  • Programs and tests on board include the routine tests a practice runs before the first load of the day
  • The intelligent diagnosis system identifies the failing section rather than showing a generic error
  • Each unit is aged tested before shipment, with an aging test programme measured in days not hours
  • Cycle data is retained on removable media so a failed cycle can be traced after the fact

Certifications And Conformity

  • EN 13060 small steam sterilizer
  • IEC 61010-1
  • IEC 61010-2-040
Options

Configuration And Customization

Automatic water filling system in place of manual filling

Built in water quality detection

Built in thermal printer or external printer for cycle records

Instruments management assistant trays for mirrors, probes and similar small instruments

Multi language operating system set to the destination market

OEM and ODM builds for distributors, discussed case by case

Comparison

How The Novo Pro 23L LED Compares

Compared WithWhat Changes
Class N sterilizerA Class N unit only handles unwrapped solid instruments; the Novo Pro 23L LED also processes wrapped and hollow loads, at a higher purchase price
Novo Pro 23LThe 23L LED variant uses a simpler LED interface and fewer buttons; the 23L touchscreen model is easier for rotating staff to learn
Novo Pro 23L LED with automatic fillingThe standard model requires manual filling; the automatic version reduces operator effort and risk of overfilling
Central sterile servicesSending instruments out removes the equipment cost but adds a transport cycle and a second set of instruments
Use Guide

Running The Novo Pro 23L LED Day To Day

  • Fill the clean water tank with distilled water below 5 microsiemens per cm and check the level indicator
  • Run the daily test programme before the first patient load
  • Load trays so pouches lie flat with the paper side up and do not touch the chamber wall
  • Select the program that matches the load: wrapped, hollow or solid
  • Use extra drying for dense instrument assemblies or anything that has come out damp before
  • Empty the waste water tank when prompted and never return waste water to the clean tank
  • Keep the SD card in place so every cycle is recorded, and archive the file periodically
Joident Novo Pro 23L LED steam sterilizer, view 7
FAQ

Novo Pro 23L LED Questions

What is the difference between Class B and Class N sterilization
Class B uses fractionated vacuum to pull air out of the chamber before steam enters, so steam reaches wrapped instruments and the inside of hollow handpieces. Class N handles unwrapped solid instruments only. The Novo Pro 23L LED runs Class B cycles conforming to EN 13060.
What water does the sterilizer need
Feed water must meet EN 13060 Annex C, which means conductivity below 5 microsiemens per centimetre. Distilled water from a Distilo water distiller meets this. Tap water scales the boiler and shortens the life of the machine.
How many instrument trays fit in one load
The carrier takes up to five trays, or three trays when they are rotated 90 degrees. The steel wire carrier measures 410 x 205 x 200 mm and the aluminium trays 380 x 193 x 16 mm.
How are cycle records kept for an inspection
Every cycle is written to SD card or thermal printer. A built-in or external printer is available as an option, so a paper record can be attached to the day sheet as well.
What power supply does it need
200-240 Vac, 50/60 Hz single phase, nominally 230 Vac at 50 Hz, drawing 1700 W and protected by a 10 A fuse. Plan a dedicated circuit rather than sharing a socket with other equipment.
Can it be used at altitude
The unit is rated to 3500 m above sea level. Above that height it must not be used, because the pressure and temperature relationship the cycle depends on no longer holds.
Do you supply OEM or ODM versions for distributors
Yes. Joident supplies distributors and OEM or ODM partners, including a multi language operating system set for the destination market. Send your requirement on WhatsApp or by email and we will confirm what is feasible.

Related Products

Joident Novo Pro 23L
Steam Sterilizer

Novo Pro 23L

The Novo Pro 23L is a Class B steam sterilizer designed for small to mid-size reprocessing rooms where space i.

Ask About The Novo Pro 23L LED

Send the model name and your country and we will come back with a quote, lead time and the configuration options for the Novo Pro 23L LED.