Sterilization equipment for clinics that reprocess on site
Joident Novo Pro 16L LED steam sterilizer

Novo Pro 16L LED Steam Sterilizer

The Novo Pro 16L LED is a Class B steam sterilizer designed for practices needing a compact, reliable reprocessing solution.

Overview

What The Novo Pro 16L LED Is For

The Novo Pro 16L LED is a Class B steam sterilizer designed for practices needing a compact, reliable reprocessing solution. A 16 L chamber takes up to five trays, fractionated vacuum removes air from hollow and wrapped loads, and cycle data is logged to SD card. It runs on single-phase 220-240 V and occupies 585 x 438 x 405 mm, fitting into smaller treatment rooms.

60+Countries with users
8Patented technologies
1800Days of aging test
24Months warranty
Key Benefits

Why Clinics Choose The Novo Pro 16L LED

Class B fractionated vacuum sterilizes wrapped instruments and hollow handpieces

Five trays per load reduces the number of cycles needed

Cycle data is traceable via SD card, simplifying compliance

Preheating with standby reduces cycle time

Multi-language operating system simplifies use for rotating staff

Double safety locking prevents cycles starting with an open door

Application Scenarios

  • Turning around handpieces and instruments between patients in a small dental practice
  • Sterilizing wrapped surgical kits for immediate use
  • Reprocessing hollow instruments where air would block steam
  • Running an end-of-day cycle for pouched instruments
  • Maintaining a documented cycle record for audits

Who It Is For

  • Dental clinics and stomatology departments needing on-site reprocessing
  • Small hospitals and outpatient practices without a central sterile services department
  • Veterinary practices sterilizing surgical packs in house
  • Aesthetic and cosmetic clinics sterilizing reusable instruments
  • Dental equipment distributors needing a Class B sterilizer for their catalogue
Problems It Solves

What Goes Wrong Without It

  • Unwrapped-only sterilizers cannot process all load types
  • Manual cycle logs are prone to errors and loss
  • Instruments emerging damp require reprocessing, wasting time
  • Cold starts slow down the first cycles of the day
  • Tap water scales the chamber and shortens the machine’s life
Joident Novo Pro 16L LED steam sterilizer, view 6
Technical

Technical Features And Specifications

  • Class B fractionated vacuum cycles conforming to YY/T0646-2015
  • LED display with 11 programs and tests
  • Preheating system with standby to maintain chamber temperature
  • Wind cooling window with 260 x 142 mm cooling area and 73 aluminium radiating layers
  • Quick coupling connections for filling and draining
  • Intelligent monitoring and diagnosis system identifies fault sections
  • Traceability to SD card
  • Bacteriological filter retaining not less than 99.5 percent of particles above 0.3 micrometres
  • Double door locking with mechanical, sensor and pressure locks
  • Optional built-in water quality detection
Novo Pro 16L LED specifications
Cycle TypeClass B, fractionated vacuum
Chamber Volume16 L
Overall Size (L x W x H)585x438x405mm
Weight42 kg
Electrical Supply220-240 VAC-50/60Hz, single-phase
Nominal Voltage220V, 50Hz
Max Current10A
Max Working Pressure2.5 Bar(250 kPa)
Min Working Pressure-0.9 Bar(-90 kpa)
Max Temperature<145 C
Clean Water Tank3.4L
Waste Water Tank1.7L
Average Water Consumption0.15L(Min) 0.26L(Max)
Bacteriological Filternot less than 99.5 percent for particles above 0.3um
ConformityMedical Device Directive (MDD), YY/T0646-2015
Max Altitude2000 asl
Sound Power Levels< 80 DB

Materials

  • Stainless steel sterilization chamber
  • Steel wire tray carrier
  • Steel wire trays
  • Aluminium heat radiating sheets

How It Is Used In The Workflow

  • Cleaning - instruments are cleaned and dried before wrapping
  • Wrapping - pouches or reels are sealed with the cycle date visible
  • Water supply - the tank is filled with distilled water
  • Cycle selection - the operator selects a program on the LED display
  • Fractionated vacuum - air is removed from wrapped and hollow loads
  • Sterilization and drying - the cycle holds temperature and dries
  • Record - the cycle is written to SD card

Quality Control

  • Vacuum and pressure limits are monitored on every cycle
  • Programs include routine tests
  • The diagnosis system identifies the failing section
  • Each unit undergoes an 1800-day aging test
  • Cycle data is retained on SD card for traceability

Certifications And Conformity

  • EN 13060 small steam sterilizer
  • IEC 61010-1
  • IEC 61010-2-040
Options

Configuration And Customization

Optional automatic water filling system

Optional built-in water quality detection

Optional external thermal printer

Instruments management assistant trays

Multi-language operating system

Comparison

How The Novo Pro 16L LED Compares

Compared WithWhat Changes
Class N sterilizerA Class N unit only handles unwrapped solids; the Novo Pro 16L LED also processes wrapped and hollow loads
Novo Pro 23LThe 23 L chamber suits a busier practice and uses more water per cycle; the 16 L is more compact
Central sterile servicesOutsourcing removes equipment cost but adds transport time and a second set of instruments
Use Guide

Running The Novo Pro 16L LED Day To Day

  • Fill the clean water tank with distilled water and check the level indicator
  • Run the daily test program before the first patient load
  • Load trays so pouches lie flat and do not touch the chamber wall
  • Select the appropriate program for the load type
  • Empty the waste water tank when prompted
  • Keep the SD card in place for cycle recording
Joident Novo Pro 16L LED steam sterilizer, view 7
FAQ

Novo Pro 16L LED Questions

What is the difference between Class B and Class N sterilization
Class B uses fractionated vacuum to remove air, reaching wrapped instruments and hollow handpieces. Class N handles unwrapped solids only. The Novo Pro 16L LED runs Class B cycles.
What water quality is required
Feed water must have a conductivity of less than 15uS/cm. Distilled water is recommended.
How many instrument trays fit in one load
The carrier takes up to five trays, or three when rotated 90 degrees.
How are cycle records kept
Every cycle is written to SD card. An external thermal printer is available as an option.
What power supply does it need
220-240 VAC, 50/60 Hz single phase, drawing 10A.
What is the warranty period
24 months or 2000 cycles, whichever comes first.
Can this sterilizer be used at high altitude
The unit is rated to 2000m above sea level. Above that height, it must not be used.

Related Products

Joident Novo Pro 12L steam sterilizer
Steam Sterilizer

Novo Pro 12L

The Novo Pro 12L is a Class B steam sterilizer designed for small to mid-size clinics that need reliable, auto.

Joident Novo Pro 18L steam sterilizer
Steam Sterilizer

Novo Pro 18L

The Novo Pro 18L is a Class B steam sterilizer for clinics that need to reprocess instruments quickly between.

Joident Novo Pro 8L steam sterilizer
Steam Sterilizer

Novo Pro 8L

The Novo Pro 8L is a Class B steam sterilizer for clinics and studios that need to reprocess instruments quick.

Ask About The Novo Pro 16L LED

Send the model name and your country and we will come back with a quote, lead time and the configuration options for the Novo Pro 16L LED.