Sterilization equipment for clinics that reprocess on site
Joident Novo Pro 12L steam sterilizer

Novo Pro 12L Steam Sterilizer

The Novo Pro 12L is a Class B steam sterilizer designed for small to mid-size clinics that need reliable, automated sterilization in limited space.

Overview

What The Novo Pro 12L Is For

The Novo Pro 12L is a Class B steam sterilizer designed for small to mid-size clinics that need reliable, automated sterilization in limited space. A 12 L chamber fits up to five trays, supports wrapped and hollow loads, and completes cycles in as little as 20 minutes. Every cycle is logged to SD card or thermal printer, and the preheating system reduces time between loads. It runs on single-phase 220-240 V and occupies 685 x 438 mm of bench space, making it suitable for back rooms or compact reprocessing areas.

60+Countries with users
8Patented technologies
1800Days of aging test
24Months warranty
Key Benefits

Why Clinics Choose The Novo Pro 12L

Class B fractionated vacuum cycles process wrapped instruments and hollow loads, not only unwrapped solids

Five trays per load reduce the number of cycles needed during a busy session

Every cycle is recorded on SD card or thermal printer, so compliance records are traceable without manual entry

Preheating with standby maintains chamber temperature between cycles, cutting time for the next load

Intelligent monitoring identifies the failing component and displays a fault message with a suggested fix

The door will not open under pressure or start a cycle if not properly locked, ensuring operator safety

Application Scenarios

  • Sterilizing wrapped instruments and hollow handpieces between patients in a single-chair dental practice
  • Processing small surgical packs and reusable cannulas in a cosmetic or aesthetic clinic
  • Reprocessing instruments in a tattoo or piercing studio where infection control is critical
  • Running a quick emergency cycle for solid instruments when a patient is waiting
  • Maintaining compliance records for a practice audit with cycle data stored on removable media

Who It Is For

  • Dental clinics and stomatology departments reprocessing instruments on site between patients
  • Small hospitals and outpatient practices without a central sterile services department
  • Aesthetic and cosmetic clinics that sterilize reusable tools and instrument sets
  • Veterinary practices sterilizing small surgical packs in house
  • Dental equipment distributors who need a Class B model with documented conformity for their catalogue
Problems It Solves

What Goes Wrong Without It

  • Unwrapped only sterilizers cannot process pouched or hollow loads, which limits what a practice can offer
  • Handwritten cycle logs are the first thing an inspection questions and the easiest thing to lose
  • Instruments coming out damp have to be reprocessed, which wastes a cycle and a working half hour
  • Cold starts make the first cycles of the day the slowest, exactly when the schedule is fullest
  • Tap water scales the chamber and the boiler and shortens the life of the machine
Joident Novo Pro 12L steam sterilizer, view 6
Technical

Technical Features And Specifications

  • Fractionated vacuum Class B cycles conforming to EN 13060
  • Preheating system with standby that maintains a minimum chamber temperature between cycles
  • Wind cooling window with a 260 x 142 mm cooling area, 73 aluminium radiating layers and 18 radiating pipes
  • Quick coupling connections on the front for filling and draining, with an optional automatic filling system
  • Intelligent monitoring and diagnosis that names the failed section and shows the fault message on screen
  • Traceability to SD card or thermal printer, with a built in automatic printer or external printer as options
  • Bacteriological filter retaining not less than 99.5 percent of particles above 0.3 micrometres
  • Double safety door locking combining a mechanical lock, a sensor switch and an electromagnetic lock
  • Optional built in water quality detection that warns before poor feed water reaches the boiler
Novo Pro 12L specifications
Cycle TypeClass B, fractionated vacuum
Chamber Volume12 L
Chamber Dimensionsdiameter 245 mm x 445 mm
Overall Size (L x W x H)685 x 438 x 405 mm
Weightapprox. 60 kg
Electrical Supply220-240 Vac, 50/60 Hz, single phase
Nominal Voltage220 Vac / 50 Hz
Max Current10 A
Fuse10 A
Max Working Pressure2.5 bar (250 kPa)
Min Working Pressure-0.9 bar (-90 kPa)
Max Temperaturebelow 145 C
Clean Water Tank3.5 L
Waste Water Tank1.7 L
Water Consumption Per Cycle0.17 L min to 0.31 L max
Feed Water QualityEN 13060 Annex C, conductivity below 15 microsiemens per cm
Tray Capacityup to 5 trays, or 3 trays rotated 90 degrees
Bacteriological Filternot less than 99.5 percent for particles above 0.3 micrometres
Max Altitude2000 m above sea level
Sound Power Levelbelow 80 dB
ConformityEN 13060, IEC 61010-1, IEC 61010-2-040, EN 61326

Materials

  • Stainless steel sterilization chamber
  • Steel wire tray carrier
  • Aluminium instrument trays
  • Aluminium finned heat exchanger for the cooling window

How It Is Used In The Workflow

  • Load preparation - instruments are cleaned in an ultrasonic cleaner and dried before wrapping
  • Wrapping - pouches or reels are sealed on a thermal sealer with the cycle date visible
  • Water supply - the tank is filled with distilled water below 15 microsiemens per cm
  • Cycle selection - the operator picks one of the 11 programs and tests on the touchscreen
  • Fractionated vacuum - repeated vacuum and steam pulses remove air from wrapped and hollow loads
  • Sterilization and drying - the cycle holds temperature, then dries, with extra drying available
  • Record - the cycle is written to SD card or thermal printer and stored for compliance

Quality Control

  • Vacuum and pressure limits are monitored on every cycle and the cycle aborts if a limit is missed
  • Programs and tests on board include the routine tests a practice runs before the first load of the day
  • The intelligent diagnosis system identifies the failing section rather than showing a generic error
  • Each unit is aged tested before shipment, with an aging test programme measured in days not hours
  • Cycle data is retained on removable media so a failed cycle can be traced after the fact

Certifications And Conformity

  • EN 13060 small steam sterilizer
  • IEC 61010-1
  • IEC 61010-2-040
Options

Configuration And Customization

Automatic water filling system in place of manual filling

Built in water quality detection

Built in automatic printer or external printer for cycle records

Instruments management assistant trays for mirrors, probes and similar small instruments

Multi language operating system set to the destination market

OEM and ODM builds for distributors, discussed case by case

Comparison

How The Novo Pro 12L Compares

Compared WithWhat Changes
Class N sterilizerA Class N unit only handles unwrapped solid instruments; the Novo Pro 12L also processes wrapped and hollow loads, at a higher purchase price
Novo Pro 18LThe 18 L chamber suits a single chair practice and uses less water per cycle; the 12 L takes fewer trays per load when the schedule is full
Novo Pro 12L LEDThe LED variant covers the same chamber with a simpler indicator interface; the 12L touchscreen model is easier for rotating staff to learn
Central sterile servicesSending instruments out removes the equipment cost but adds a transport cycle and a second set of instruments
Use Guide

Running The Novo Pro 12L Day To Day

  • Fill the clean water tank with distilled water below 15 microsiemens per cm and check the level indicator
  • Run the daily test programme before the first patient load
  • Load trays so pouches lie flat with the paper side up and do not touch the chamber wall
  • Select the program that matches the load: wrapped, hollow or solid
  • Use extra drying for dense instrument assemblies or anything that has come out damp before
  • Empty the waste water tank when prompted and never return waste water to the clean tank
  • Keep the SD card in place so every cycle is recorded, and archive the file periodically
Joident Novo Pro 12L steam sterilizer, view 2
FAQ

Novo Pro 12L Questions

What is the difference between Class B and Class N sterilization
Class B uses fractionated vacuum to pull air out of the chamber before steam enters, so steam reaches wrapped instruments and the inside of hollow handpieces. Class N handles unwrapped solid instruments only. The Novo Pro 12L runs Class B cycles conforming to EN 13060.
What water does the sterilizer need
Feed water must meet EN 13060 Annex C, which means conductivity below 15 microsiemens per centimetre. Distilled water from a Distilo water distiller meets this. Tap water scales the boiler and shortens the life of the machine.
How are cycle records kept for an inspection
Every cycle is written to SD card or thermal printer. A built in automatic printer and an external printer are both available as options, so a paper record can be attached to the day sheet as well.
Can it be used at altitude
The unit is rated to 2000 m above sea level. Above that height it must not be used, because the pressure and temperature relationship the cycle depends on no longer holds.
Do you supply OEM or ODM versions for distributors
Yes. Joident supplies distributors and OEM or ODM partners, including a multi language operating system set for the destination market. Send your requirement on WhatsApp or by email and we will confirm what is feasible.

Related Products

Joident Novo Pro 8L steam sterilizer
Steam Sterilizer

Novo Pro 8L

The Novo Pro 8L is a Class B steam sterilizer for clinics and studios that need to reprocess instruments quick.

Joident Novo Pro 18L steam sterilizer
Steam Sterilizer

Novo Pro 18L

The Novo Pro 18L is a Class B steam sterilizer for clinics that need to reprocess instruments quickly between.

Ask About The Novo Pro 12L

Send the model name and your country and we will come back with a quote, lead time and the configuration options for the Novo Pro 12L.