Sterilization equipment for clinics that reprocess on site
Joident Novo Pro 8L steam sterilizer

Novo Pro 8L Steam Sterilizer

The Novo Pro 8L is a Class B steam sterilizer for clinics and studios that need to reprocess instruments quickly between appointments.

Overview

What The Novo Pro 8L Is For

The Novo Pro 8L is a Class B steam sterilizer for clinics and studios that need to reprocess instruments quickly between appointments. An 8 L chamber takes up to five trays, fractionated vacuum removes air from wrapped and hollow loads, and cycle data is logged to SD card. It runs on single-phase 220-240 V and occupies 685 x 438 x 405 mm.

60+Countries with users
8Patented technologies
1800Days of aging test
24Months warranty
Key Benefits

Why Clinics Choose The Novo Pro 8L

Class B fractionated vacuum sterilizes wrapped instruments and hollow handpieces

Five trays per load reduce the number of cycles needed between patients

Cycle data is traceable on SD card, supporting compliance without manual logging

Preheating with standby reduces cycle time by maintaining chamber temperature

The intelligent diagnosis system identifies the failing section and displays the fault message

Double door locking prevents cycles from starting on an unlocked door

Application Scenarios

  • Turning around handpieces and instruments in a one to three chair dental practice
  • Sterilizing wrapped surgical kits for immediate use
  • Reprocessing hollow instruments where air would prevent steam penetration
  • Running an end of day cycle of pouched instruments with extra drying
  • Providing a stored cycle record for practice inspections

Who It Is For

  • Dental clinics and stomatology departments reprocessing instruments on site
  • Tattoo and piercing studios needing reliable sterilization
  • Small hospitals and outpatient practices without a central sterile services department
  • Beauty and aesthetic clinics sterilizing reusable tools
  • Medical device distributors needing a documented Class B sterilizer
Problems It Solves

What Goes Wrong Without It

  • Unwrapped sterilizers cannot process pouched or hollow loads
  • Manual cycle logs are prone to errors and can be lost
  • Instruments coming out damp require reprocessing, wasting time and resources
  • Cold starts lengthen cycle times when the schedule is busiest
  • Maintaining water quality requires frequent monitoring and cleaning
Joident Novo Pro 8L steam sterilizer
Technical

Technical Features And Specifications

  • Class B fractionated vacuum cycles conforming to EN 13060
  • 260 x 142 mm cooling area with 73 aluminium radiating layers and 18 radiating pipes
  • Quick coupling connections for filling and draining
  • Intelligent monitoring and diagnosis system with fault message display
  • Traceability to SD card
  • Bacteriological filter retaining not less than 99.5 percent of particles above 0.3 micrometres
  • Double safety door locking with mechanical, sensor and electromagnetic locks
  • Water tank group is accessible for cleaning and inspection
  • Optional automatic water filling system
Novo Pro 8L specifications
Cycle TypeClass B, fractionated vacuum
Chamber Volume8 L
Chamber Dimensions245 mm x D445 mm
Usable chamber volume198 mm x 204mm x 385mm
Overall Size (L x W x H)685x438x405mm
Weight60kg
Electrical Supply220-240 VAC-50/60Hz, single-phase
Nominal voltage220V, 50Hz
Max current10A
Max. altitude2000 asl
Max Working Pressure2.5 Bar(250 kPa)
Min Working Pressure-0.9 Bar(-90 kpa)
Max Temperature<145 C
Clean water tank3.5L
Sewage tank1.7L
Water QualityEC(conductivity<15uS/cm)
Average water consumption0.17L(Min) 0.31L(Max)
Bacteriological filterThe filtration efficiency of particles above 0.3um be no less than 99.5%
Conformity93/42/EEC, EN 13060, IEC 61010-1, IEC 61010-2-040, EN 61326

Materials

  • Stainless steel sterilization chamber
  • Steel wire tray carrier
  • Aluminium instrument trays
  • Aluminium finned heat exchanger

How It Is Used In The Workflow

  • Load preparation - instruments are cleaned and dried before wrapping
  • Wrapping - pouches or reels are sealed with the cycle date visible
  • Water supply - the tank is filled with distilled water below 15 microsiemens per cm
  • Cycle selection - the operator picks one of the 11 programs and tests
  • Fractionated vacuum - repeated vacuum and steam pulses remove air
  • Sterilization and drying - the cycle holds temperature, then dries
  • Record - the cycle is written to SD card

Quality Control

  • Vacuum and pressure limits are monitored on every cycle
  • Programs include routine tests for daily verification
  • The diagnosis system identifies the failing section
  • Each unit is aged tested before shipment
  • Cycle data is retained on removable media

Certifications And Conformity

  • EN 13060 small steam sterilizer
  • IEC 61010-1
  • IEC 61010-2-040
Options

Configuration And Customization

Automatic water filling system

Built in thermal printer

Instruments management assistant trays

Multi language operating system

Comparison

How The Novo Pro 8L Compares

Compared WithWhat Changes
Class N sterilizerA Class N unit only handles unwrapped solids; the Novo Pro 8L also processes wrapped and hollow loads
Novo Pro 23LThe 23 L chamber suits a larger practice and uses more water per cycle; the 8 L is for fewer instruments
Central sterile servicesSending instruments out removes the equipment cost but adds transport time and a second set of instruments
Use Guide

Running The Novo Pro 8L Day To Day

  • Fill the clean water tank with distilled water and check the level indicator
  • Run the daily test programme before the first load
  • Load trays so pouches lie flat and do not touch the chamber wall
  • Select the program that matches the load
  • Empty the waste water tank when prompted and never return waste water to the clean tank
  • Keep the SD card in place so every cycle is recorded
Joident Novo Pro 8L steam sterilizer, view 2
FAQ

Novo Pro 8L Questions

What is the chamber volume
The Novo Pro 8L has an 8 L chamber with dimensions 245 mm x D445 mm.
What water does the sterilizer need
Feed water must have a conductivity below 15 microsiemens per centimetre. Distilled water is recommended.
How many instrument trays fit in one load
The carrier takes up to five trays, or three trays when rotated 90 degrees.
What power supply does it need
The unit requires a 220-240 VAC, 50/60Hz, single-phase power supply with a maximum current of 10A.
What certifications does it have
The Novo Pro 8L conforms to 93/42/EEC, EN 13060, IEC 61010-1, IEC 61010-2-040 and EN 61326.
What is the warranty period
The Novo Pro 8L comes with a 24 month or 2000 cycle warranty, whichever comes first.
What happens if the sterilizer fails
The intelligent diagnosis system identifies the failing section and displays the fault message on screen.

Related Products

Joident Novo Pro 12L steam sterilizer
Steam Sterilizer

Novo Pro 12L

The Novo Pro 12L is a Class B steam sterilizer designed for small to mid-size clinics that need reliable, auto.

Joident Novo Pro 18L steam sterilizer
Steam Sterilizer

Novo Pro 18L

The Novo Pro 18L is a Class B steam sterilizer for clinics that need to reprocess instruments quickly between.

Ask About The Novo Pro 8L

Send the model name and your country and we will come back with a quote, lead time and the configuration options for the Novo Pro 8L.