Injection moulds and moulded parts since 2000 22 Xianghong Road, Xiang An, Xiamen, China Tel +86 592 7760777
[email protected]
Precision mould inserts, blades and core pins machined in the XSY tool room
Industry

Injection Moulds For Medical Instrument

Instrument housings and moulded components for medical equipment makers

Pain Points

What Makes Medical Instrument Parts Difficult

Medical housings are often low volume with a long service life, so tool life matters more than cycle time

Changes have to be traceable, and an undocumented bench correction on the tool is a problem at audit

Cosmetic and functional requirements sit on the same part with little room to trade one against the other

Requirements

What Buyers In This Sector Need

  • A mould maker who records what was changed on the tool and when
  • First article measurement against the drawing, issued as a report
  • Steel and finish choices documented so a later repair does not change the part
Where It Is Used

Typical Application Scenarios

An instrument maker with a housing that has to stay identical across a long product life

A device company needing a second source for an existing moulded component

Delivery Capability

How A Project Runs

Design review

Part geometry, wall sections, draft and gate position are reviewed against the moulding material before any steel is cut.

Steel inspection

Cavity and core blocks are checked on arrival so that the hardness and grade match what the mould was quoted with.

In-process measurement

Machined inserts, slides and plates are measured between operations rather than only at the end of the tool room route.

Fitting and spotting

Parting line, slide movement and ejection are fitted by hand before the mould goes to the press.

FAQ

Medical Instrument Questions

What buyers in this sector ask before placing tooling work.

Do you issue a measurement report with trial samples?

Yes. Trial parts are measured on the 2D image measuring projector against the dimensions you nominate on the drawing, and the report travels with the samples rather than following later.

How are later tool changes recorded?

Each correction is written against the mould number with the date and the reason, so that a repair years later starts from what the tool actually is rather than from the original drawing.

Tooling For Medical Instrument

Send the part, the moulding grade and the volume. We will name the cavity steel and the impression count in the quotation rather than after the order.