Risheng PX logo
Transformer Bushing Insulators production at Risheng

Transformer Bushing Insulators

Porcelain bushings that carry transformer winding leads through the tank wall, insulate them to ground and hold them in place.

42 products

Every Transformer Bushing Insulators We Make

24kV porcelain transformer bushing with brown glazed shed profile

High Voltage Transformer Bushings

24kV Porcelain Transformer Bushing 150kV BIL

  • Wet Power Frequency Withstand Voltage 60 kV
  • Net Weight Per Bushing 8 kg
  • Height 453 mm
View details
DIN 20NF630A porcelain transformer bushing with brown glazed sheds

High Voltage Transformer Bushings

DIN 20NF630A Transformer Bushing 440mm Creepage

  • Nominal Creepage Distance 440 mm
  • Net Weight 6.1 kg
  • Height 385 mm
View details
DIN 24kV 630A transformer bushing CD525 with extended shed profile

High Voltage Transformer Bushings

DIN 24kV 630A Transformer Bushing CD525

  • Creepage Distance 525 mm
  • Net Weight 6.8 kg
  • Height 385 mm
View details
DT 33kV 250A porcelain transformer bushing with brown glaze

High Voltage Transformer Bushings

DT 33kV 250A Porcelain Transformer Bushing

  • Rated Voltage 33 kV
View details
DIN 20NF250A transformer bushing CD480 with brown porcelain sheds

High Voltage Transformer Bushings

DIN 20NF250A Transformer Bushing CD480

  • Creepage Distance 480 mm
  • Power Frequency Withstand Voltage 50 kV
  • Lightning Impulse Withstand Voltage 125 kV
View details
Russia 10kV wall bushing ceramic insulator with flange

Wall Bushings And Other Insulators

Russia 10kV Wall Bushing Ceramic Insulator IOR-10-3.75 II UKhL2

  • Voltage 10 kV
  • Current 630 A
  • Lightning Impulse Test Voltage 80 kV
View details
DIN 42530 1NF250A low voltage transformer bushing

Low Voltage Transformer Bushings

DIN 42530 1NF250A Low Voltage Transformer Bushing

  • Creepage Distance 50 mm
  • Net Weight 0.26 kg
View details
IO-10/4 UKhL3 post bushing insulator

Wall Bushings And Other Insulators

IO-10/4 UKhL3 Post Bushing Insulator Catalogue Item

  • Class GOST Ceramic Construction 10 kV
View details
ANSI 15kV transformer porcelain bushing

Screw Thread Transformer Bushings

ANSI 15kV Transformer Porcelain Bushing

  • Rated Transformer Bushing 15 kV
View details
CB250 outdoor transformer porcelain bushing

Low Voltage Transformer Bushings

CB250 Outdoor Transformer Porcelain Bushing

    View details
    Outdoor pole mounted drop-out fuse cutout with porcelain body

    Fuse Cutout Bushings

    Outdoor Pole Mounted Drop-Out Fuse Cutout RW11-10

    • Impulse Voltage BIL On Both Ratings 110 kV
    • Power Frequency Withstand Voltage 42 kV
    View details
    DIN 42539 3kV 250A transformer bushing

    Low Voltage Transformer Bushings

    DIN 42539 3kV 250A Transformer Bushing DT3KV-250A

    • Creepage Distance 120 mm
    View details
    DIN 42530 1kV 1250A transformer bushing

    Low Voltage Transformer Bushings

    DIN 42530 1kV 1250A Transformer Bushing

    • Current 1250 A
    • Creepage Distance 50 mm
    • Weight 0.26 kg
    View details
    EN 50180 24kV 250A transformer bushing Type 3

    High Voltage Transformer Bushings

    EN 50180 24kV 250A Transformer Bushing Type 3

      View details
      DIN 30NF250 36kV transformer bushing

      High Voltage Transformer Bushings

      DIN 30NF250 36kV Transformer Bushing

      • High Voltage Class 36 kV
      View details
      EN 50180 24kV 250A porcelain transformer bushing

      High Voltage Transformer Bushings

      EN 50180 24kV 250A Porcelain Transformer Bushing

      • Standard IEC60137
      View details
      DIN 42531 30NF250A transformer bushing

      High Voltage Transformer Bushings

      DIN 42531 30NF250A Transformer Bushing

      • DIN 42531 30NF Pattern 250 A
      View details
      DIN 42531 10NF250A transformer bushing ceramic insulator

      High Voltage Transformer Bushings

      DIN 42531 10NF250A Transformer Bushing

      • DIN 42531 10NF Pattern 250 A
      View details
      DIN 42539 3kV 630A outdoor transformer bushing

      Low Voltage Transformer Bushings

      DIN 42539 3kV 630A Outdoor Transformer Bushing DT 3/630

      • Tank Hole Size 45 mm
      • BIL 40 kV
      • Creepage Distance 120 mm
      View details
      DIN 42530 1kV 2000A transformer bushing ceramic insulator

      Low Voltage Transformer Bushings

      DIN 42530 1kV 2000A Transformer Bushing

      • Creepage Distance At This Rating 75 mm
      • Weight 1.29 kg
      • Creepage Distance 50 mm
      View details
      BUCHA 24kV 160A high voltage porcelain bushing

      Wall Bushings And Other Insulators

      BUCHA 24kV 160A HV Porcelain Bushing C-450

      • Creepage Distance, Catalogued As C-450 450 mm
      • Diameter 105 mm
      • Height 550 mm
      View details
      BUCHA 24kV 160A 450mm ceramic bushing isolator

      Wall Bushings And Other Insulators

      BUCHA 24kV 160A 450mm Ceramic Bushing Isolators

      • Creepage Distance 450 mm
      • Diameter 105 mm
      • Height 550 mm
      View details
      24kV to 36kV high voltage porcelain transformer bushing

      High Voltage Transformer Bushings

      24kV To 36kV HV Porcelain Transformer Bushing

        View details
        DIN 42531 20NF-250A transformer bushing isolators

        High Voltage Transformer Bushings

        DIN 42531 20NF250A Transformer Bushing Isolators

        • DIN 42531 20NF Pattern 250 A
        View details
        20NF250A bushing conductor and flange

        High Voltage Transformer Bushings

        DIN 20NF250A Transformer Bushing Insulators

        • DIN 20NF Pattern 250 A
        View details
        Threaded ANSI 18kV transformer bushing

        Screw Thread Transformer Bushings

        Threaded ANSI 18kV Transformer Bushing ANSI-18/50

        • Overall Height H 541 mm
        • Creep Distance 480 mm
        • Weight 3.5 kg
        View details
        18kV 25A high voltage ANSI transformer bushing

        High Voltage Transformer Bushings

        18kV 25A HV ANSI Transformer Bushing

        • Creep Distance 480 mm
        • Weight 3.5 kg
        View details
        15kV to 33kV fuse cut out bushing insulator

        Fuse Cutout Bushings

        15kV To 33kV Fuse Cut Out Bushing Insulator

          View details
          10NF250A bushing brass rod conductor detail

          High Voltage Transformer Bushings

          DIN 10NF250A Transformer Bushing For Oil-Immersed Transformers

          • DIN 10NF Pattern 250 A
          View details
          DIN 42539 3kV 1000A transformer bushing

          Low Voltage Transformer Bushings

          DIN 42539 3kV 1000A Transformer Bushing

          • Creepage Distance 125 mm
          View details
          EN 50386 1kV 2000A outdoor transformer bushing

          Low Voltage Transformer Bushings

          EN 50386 1kV 2000A Outdoor Transformer Bushing

          • Creepage Distance 75 mm
          • Weight 1.29 kg
          View details
          DIN 42530 1kV 630A ceramic bushing insulator

          Low Voltage Transformer Bushings

          DIN 42530 1kV 630A Ceramic Bushing DT 1/630

          • Tank Hole Size 45 mm
          • Creepage Distance 75 mm
          • Weight 0.26 kg
          View details
          1.2kv 400A transformer bushing insulator

          Screw Thread Transformer Bushings

          1.2kV 400A Screw Thread Transformer Bushing

            View details
            Threaded 1kV LV ANSI transformer bushing

            Screw Thread Transformer Bushings

            Threaded 1kV LV ANSI Transformer Bushing 30kV BIL

            • Rated Voltage 1 kV
            • BIL 30 kV
            View details
            1.2kV 160A bushing threaded rod and nut

            Screw Thread Transformer Bushings

            1.2kV 160A Transformer Bushing Insulator

              View details
              DIN 42530 1kV 3150A transformer bushing insulator

              Low Voltage Transformer Bushings

              DIN 42530 1kV 3150A Transformer Bushing DT 1/3150

              • Tank Hole Size 90 mm
              • Creepage Distance 75 mm
              View details
              1.2KV800A ANSI low voltage bushing ceramic insulator

              Low Voltage Transformer Bushings

              1.2kV 800A ANSI Low Voltage Bushing 30kV BIL

              • Rated Voltage 1.2 kV
              • BIL 30 kV
              View details
              AS 15/50 transformer bushing insulator for 15kV

              High Voltage Transformer Bushings

              AS 15/50 Transformer Bushing Insulator 15kV

              • Voltage 15 kV
              • Height 485 mm
              • Diameter 101 mm
              View details
              AS 24/315 transformer bushing insulator for 24kV

              High Voltage Transformer Bushings

              AS 24/315 Transformer Bushing Insulator 24kV

              • Voltage 24 kV
              • Height 505 mm
              • Diameter 108 mm
              View details
              GB B-1/315 transformer bushing insulator for 1kV

              Low Voltage Transformer Bushings

              GB B-1/315 Transformer Bushing Insulator 1kV

              • Voltage 1 kV
              • Height 105 mm
              • Diameter 65 mm
              View details
              GB BLQ-10/315 transformer bushing insulator for 10kV

              High Voltage Transformer Bushings

              GB BLQ-10/315 Transformer Bushing Insulator 10kV

              • Voltage 10 kV
              • Height 240 mm
              • Diameter 115 mm
              View details
              EN 36/250/P3 transformer bushing insulator for 36kV

              High Voltage Transformer Bushings

              EN 36/250/P3 Transformer Bushing Insulator 36kV

              • Voltage 36 kV
              • Height 600 mm
              • Diameter 155 mm
              View details
              Problems this range solves

              What Buyers Come To Us With

              • Terminal boards that only accept the original dimensional pattern
              • Creepage too short for the pollution at the installation site
              • Drawings referencing DIN standards that are no longer maintained
              • Long lead times on replacement bushings during a transformer overhaul
              Core advantages

              What The Range Gives You

              • Ratings from 1kV through 52kV and up to 12500A across the range
              • DIN 42530, 42531, 42539, 52432, 42533 and 42534 patterns in production
              • Outdoor bushings manufactured and tested in accordance with IEC 60137
              • Creepage distances selected for the site rather than assumed from voltage
              Who it is for

              Suited To

              • Distribution and power transformer manufacturers
              • Transformer repair and rewinding workshops
              • Utility procurement teams holding spares
              Application scenarios

              Where It Is Used

              • Oil-immersed distribution transformers
              • Power transformers in substations
              • Generator connections into transmission lines
              • Transformer refurbishment and rewinding
              Questions

              Transformer Bushing Insulators Questions

              What voltage and current ratings do you cover?
              From 1kV through to 52kV and up to 12500A, with a wide variety of creepage distances.
              Do you still make the historical DIN patterns?
              Yes. DIN specifications are no longer live standards but are still used widely by transformer and distribution manufacturers, so we keep both DIN and EN patterns in production.
              What test standard applies to outdoor bushings?
              All outdoor bushings are manufactured and tested in accordance with IEC 60137.
              Can you work from a sample instead of a drawing?
              Yes. Send a sample or photographs and we will produce to it.
              How do I choose the creepage distance?
              From the environmental conditions at the site. Describe the location, including any salt, cement dust or industrial fallout, and we will recommend the class.

              Talk To An Engineer About Transformer Bushing Insulators

              Send the drawing, the pollution class at the site, or a photograph of the part you are replacing. A reply comes back within 24 hours.