AS 24/315 Transformer Bushing Insulator 24kV

High Voltage Transformer Bushings
Product Overview
An Australian Standard AS 24/315 transformer bushing rated 24 kV, 505 mm tall and 108 mm in diameter. Creepage is 450 mm with a 251 mm arcing distance, and the unit weighs 4.5 kg. Against the AS 15/50 it adds 140 mm of creepage and nearly 100 mm of arcing distance for only 20 mm more height.
Key benefits
Why Buyers Choose This Part
- 450 mm creepage with a 251 mm arcing distance at 24 kV
- Only 20 mm taller than the 15 kV part despite the extra creepage
- 108 mm diameter still suits closely spaced terminal boards
- Australian Standard pattern available with DIN, EN and ANSI ranges
Application scenarios
Where It Is Used
- 24 kV distribution transformers built to Australian Standard
- Networks stepping up from 15 kV to 24 kV on existing terminal layouts
- Outdoor terminals needing longer creepage at 24 kV
- Replacement of installed AS 24/315 bushings
Who it is for
Who It Suits
- Transformer manufacturers working to Australian Standard
- Utilities operating 24 kV AS-specified networks
- Distributors supplying AS pattern bushings
Problems it solves
What Goes Wrong Without The Right Part
- Creepage shortfalls when a 15 kV bushing is reused at 24 kV
- Height clearances that a much taller bushing would breach
- AS pattern parts unavailable from IEC-focused suppliers
- Mixed voltage classes across one transformer fleet
Technical features
How It Is Built
- Australian Standard AS 24/315
- Rated voltage 24 kV
- 505 mm height
- 108 mm diameter
- 450 mm creepage distance
- 251 mm arcing distance
- 4.5 kg weight
Specifications
Published Figures For This Product
Every value below comes from the manufacturer data for this item. Figures not listed are confirmed against the drawing before an order is placed.
| Voltage | 24 kV |
|---|---|
| Height | 505 mm |
| Diameter | 108 mm |
| Creepage Distance | 450 mm |
| Arcing Distance | 251 mm |
| Weight | 4.5 kg |
Materials
Materials
- Electrical porcelain shell
- Copper or aluminium alloy conductor
Manufacturing
Process
- Forming
- Glazing
- Firing
- Conductor assembly
- Routine electrical test
Quality control
Testing
- Creepage verified against the 450 mm figure
- Arcing distance checked at 251 mm
- Dimensional check on the 505 mm by 108 mm envelope
Certifications
Certification
- Australian Standard pattern
- ISO 9001 quality management system
Customisation
Customisation Options
- AS 15/50 available for the lower voltage class
- Special lengths and screw sizes to specification
- Produced to drawing or sample
Comparison
How It Compares
| AS 15/50 | The 15/50 gives 310 mm creepage and a 157 mm arcing distance at 2.8 kg. The 24/315 adds 140 mm of creepage for 20 mm more height and 1.7 kg more weight. |
|---|---|
| EN 36/250/P3 | The EN part reaches 36 kV with 935 mm creepage on a 600 mm body. Move up to it only if the network runs at 36 kV. |
Use guide
Before You Order And After It Arrives
- Do not reuse a 15 kV bushing at 24 kV, the creepage is not sufficient
- Check the 505 mm height against the transformer cover clearance
- Confirm the 108 mm diameter fits the terminal board opening
- Keep the longer creepage surface clean to preserve the margin
Questions
AS 24/315 Transformer Bushing Insulator 24kV Questions
What is the creepage distance?
450 mm, with a 251 mm arcing distance.
What are the dimensions and weight?
505 mm high, 108 mm in diameter, 4.5 kg.
How does it compare with the AS 15/50?
It adds 140 mm of creepage and 94 mm of arcing distance for 20 mm more height and 1.7 kg more weight.
What is the rated voltage?
24 kV.
Can it be made to a special length?
Yes, we manufacture to customer specifications.
How do I get a quote?
Message the quantity and designation on WhatsApp, or email [email protected]. Enquiries are answered within 24 hours.
Related
Related Products

DIN 30NF250 36kV Transformer Bushing
- High Voltage Class 36 kV

EN 50180 24kV 250A Porcelain Transformer Bushing
- Standard IEC60137

DIN 42531 30NF250A Transformer Bushing
- DIN 42531 30NF Pattern 250 A

DIN 42531 10NF250A Transformer Bushing
- DIN 42531 10NF Pattern 250 A
Keep reading
Related Cases Guides And Applications
Guide
Transformer Bushing Selection A Guide For Engineers
GuideWhat Is A High Voltage Transformer Insulator
GuideThe Five Jobs An Insulator Does Inside A High Voltage Transformer
IndustryDistribution Transformer Manufacturers
IndustryPower Utilities And Substations
SolutionManufacturing To Your Drawing Or Sample
SolutionSelecting Creepage For The Pollution At Your Site
Quote For AS 24/315 Transformer Bushing Insulator 24kV
Send the quantity and any drawing you have. Enquiries are answered within 24 hours, and we produce to customer drawings and samples.