Risheng PX logo
High Voltage Transformer Bushings production

AS 15/50 Transformer Bushing Insulator 15kV

High Voltage Transformer Bushings

Product Overview

An Australian Standard AS 15/50 transformer bushing rated 15 kV, 485 mm tall and 101 mm in diameter. Creepage is 310 mm against a 157 mm arcing distance, and the unit weighs 2.8 kg. It is the entry point of the AS bushing range, sized for the terminal boards used on Australian Standard distribution transformers.

Key benefits

Why Buyers Choose This Part

  • 310 mm creepage against a 157 mm arcing distance at 15 kV
  • Slim 101 mm diameter for tight terminal board spacing
  • 2.8 kg unit weight keeps transformer cover loading low
  • Australian Standard pattern supplied alongside DIN, EN and ANSI ranges
Application scenarios

Where It Is Used

  • 15 kV distribution transformers built to Australian Standard
  • Export projects following AS rather than IEC or ANSI
  • Terminal boards with limited spacing between phases
  • Replacement of installed AS 15/50 bushings
Who it is for

Who It Suits

  • Transformer manufacturers working to Australian Standard
  • Utilities in markets that follow AS specifications
  • Distributors supplying AS pattern bushings
Problems it solves

What Goes Wrong Without The Right Part

  • AS pattern parts that IEC and ANSI suppliers do not carry
  • Phase spacing limits that a wider bushing would breach
  • Creepage shortfalls at 15 kV in outdoor service
  • Long import lead times on Australian Standard hardware
Technical features

How It Is Built

  • Australian Standard AS 15/50
  • Rated voltage 15 kV
  • 485 mm height
  • 101 mm diameter
  • 310 mm creepage distance
  • 157 mm arcing distance
  • 2.8 kg weight
Specifications

Published Figures For This Product

Every value below comes from the manufacturer data for this item. Figures not listed are confirmed against the drawing before an order is placed.

Voltage15 kV
Height485 mm
Diameter101 mm
Creepage Distance310 mm
Arcing Distance157 mm
Weight2.8 kg
Materials

Materials

  • Electrical porcelain shell
  • Copper or aluminium alloy conductor
Manufacturing

Process

  • Forming
  • Glazing
  • Firing
  • Conductor assembly
  • Routine electrical test
Quality control

Testing

  • Creepage verified against the 310 mm figure
  • Dimensional check on the 485 mm by 101 mm envelope
  • Electrical routine test at the 15 kV class
Certifications

Certification

  • Australian Standard pattern
  • ISO 9001 quality management system
Customisation

Customisation Options

  • AS 24/315 available for the higher voltage class
  • Special lengths and screw sizes to specification
  • Produced to drawing or sample
Comparison

How It Compares

AS 24/315The 24/315 is 505 mm tall and 108 mm across with 450 mm creepage at 4.5 kg, for the 24 kV class. Match the AS designation to the network voltage.
ANSI-15/50 bushingThe ANSI-15/50 is 485 mm tall with 310 mm creep distance at 2.8 kg on the ANSI pattern. Comparable size, different standard, so order by the one on your drawing.
Use guide

Before You Order And After It Arrives

  • Confirm the drawing calls for the AS designation
  • Check the 101 mm diameter against the terminal board opening
  • Allow for the 485 mm height above the transformer cover
  • Keep the creepage surface clean in outdoor service
Questions

AS 15/50 Transformer Bushing Insulator 15kV Questions

What are the dimensions?
485 mm high, 101 mm in diameter, weighing 2.8 kg.
What is the creepage distance?
310 mm, with a 157 mm arcing distance.
What is the rated voltage?
15 kV.
Is there a higher voltage version?
Yes, the AS 24/315 at 24 kV with 450 mm creepage.
Can you produce to our drawing?
Yes, we produce to customer drawings and samples, including special lengths and screw sizes.
What other standards do you cover?
IEC, DIN, BS, AS, ANSI and GB across several hundred insulator and bushing types.

Quote For AS 15/50 Transformer Bushing Insulator 15kV

Send the quantity and any drawing you have. Enquiries are answered within 24 hours, and we produce to customer drawings and samples.