Product Overview

An EN pattern transformer bushing in the 36/250/P3 designation, rated 36 kV. It stands 600 mm tall and 155 mm across with 935 mm of creepage against a 465 mm arcing distance, weighing 6.8 kg. The creepage figure is the longest in this bushing range, which is what puts it on 36 kV transformers in heavily polluted air.

Key benefits

Why Buyers Choose This Part

  • 935 mm creepage, the longest figure in the bushing range
  • 465 mm arcing distance at the 36 kV class
  • P3 profile designation for the heaviest pollution class
  • 6.8 kg on a 600 mm body, manageable for a 36 kV part
Application scenarios

Where It Is Used

  • 36 kV transformers in coastal or heavily industrial locations
  • Substation transformers where wash access is difficult
  • Networks upgrading insulation class after repeated flashover
  • Projects specified against the EN pollution profile designations
Who it is for

Who It Suits

  • Transformer manufacturers building for polluted environments
  • Utilities operating 36 kV networks in coastal or industrial areas
  • EPC contractors specifying by pollution class
Problems it solves

What Goes Wrong Without The Right Part

  • Repeated pollution flashover at 36 kV on standard creepage bushings
  • Wash programmes that cannot be scheduled often enough
  • Creepage shortfalls that only appear after a season in service
  • Terminal designs that need long creepage without excessive height
Technical features

How It Is Built

  • EN 36/250/P3 designation
  • Rated voltage 36 kV
  • 600 mm height
  • 155 mm diameter
  • 935 mm creepage distance
  • 465 mm arcing distance
  • 6.8 kg weight
Specifications

Published Figures For This Product

Every value below comes from the manufacturer data for this item. Figures not listed are confirmed against the drawing before an order is placed.

Voltage36 kV
Height600 mm
Diameter155 mm
Creepage Distance935 mm
Arcing Distance465 mm
Weight6.8 kg
Materials

Materials

  • Electrical porcelain shell
  • Copper or aluminium alloy conductor
Manufacturing

Process

  • Forming
  • Glazing
  • Firing
  • Conductor assembly
  • Routine electrical test
Quality control

Testing

  • Creepage verified against the 935 mm figure
  • Arcing distance checked at 465 mm
  • Dimensional check on the 600 mm by 155 mm envelope
Certifications

Certification

  • EN pattern bushing
  • ISO 9001 quality management system
Customisation

Customisation Options

  • Other creepage profiles in the EN range
  • Special lengths and connection types to specification
  • Produced to drawing or sample
Comparison

How It Compares

AS 24/315The AS part gives 450 mm creepage at 24 kV on a 505 mm body. The EN 36/250/P3 more than doubles the creepage for the 36 kV class.
DIN 30NF250 at 36 kVSame voltage class on the DIN pattern. The P3 designation here identifies the long creepage pollution profile specifically.
Use guide

Before You Order And After It Arrives

  • Match the P profile designation to the site pollution class
  • Allow 600 mm of clearance above the transformer cover
  • Check the 155 mm diameter against the terminal board opening
  • Wash with clean water only when deposits build on the long creepage surface
Questions

EN 36/250/P3 Transformer Bushing Insulator 36kV Questions

What is the creepage distance?
935 mm, with a 465 mm arcing distance. It is the longest creepage figure in this bushing range.
What does the P3 in the designation mean?
It identifies the creepage profile within the EN pattern. The P3 is the long creepage version, which is why it is specified for heavily polluted sites.
What are the dimensions and weight?
600 mm high, 155 mm in diameter, 6.8 kg.
What is the rated voltage?
36 kV.
When should I choose this over a shorter creepage bushing?
When the site has salt fog, cement dust or industrial fallout, or when wash access is difficult and the surface has to hold out between cleans.
Can you supply other profiles in the range?
Yes. Tell us the site pollution class and we will recommend the profile.

Quote For EN 36/250/P3 Transformer Bushing Insulator 36kV

Send the quantity and any drawing you have. Enquiries are answered within 24 hours, and we produce to customer drawings and samples.