RCT series

RCT Plastic Ring Current Transformer

Small, light and fixed with a mounting plate. The RCT ring is the indoor metering and relay protection body for 0.66 kV boards, with five window sizes reaching a 6000/5 A ratio.

  • Primary current15 A to 6000 A
  • Secondary current5 A, 1 A
  • Standard approvalVDE 0414, BS 7626, IEC 60044-1
  • Maximum voltage0.72 / 3 kV
  • Rated load1.5 VA, 2.5 VA, 5 VA, 7.5 VA
  • Class0.5, 1.0
  • Ambient temperature-5 °C to 40 °C
  • Working placeIndoor

Product Overview

RCT type transformers are used indoors for a range of 0.66 kV and below rated voltage, rated frequency 50 Hz or 60 Hz, in AC circuits for current energy measurement or relay protection. The products use moulded case insulation, are small in size and light in weight, and use a mounting plate for fixed installation.

Working place: indoor. Ambient temperature -5 °C to 40 °C.

Application Scenarios

  • Current measurement, monitoring and protection for electrical wiring and equipment
  • Current and power measurement for electric motors, lighting, air compressors, heating and ventilation systems, air conditioning equipment and automation control systems
  • Current, power and energy monitoring devices
  • Relay protection devices

Technical Features

  • Moulded case insulation, small size and light weight
  • Mounting plate fixed installation
  • Five window sizes from 25 mm to 130 mm
  • Suitable for energy measurement and relay protection

Specifications

Ratios by frame

ModelPrimary / secondary
RCT-2515/5, 20/5, 30/5, 40/5, 50/5, 60/5, 75/5, 100/5 A
RCT-3530/5, 50/5, 60/5, 80/5, 100/5, 120/5, 150/5, 200/5, 250/5, 300/5 A
RCT-60300/5, 400/5, 500/5, 600/5, 800/5, 1000/5, 1200/5 A
RCT-901000/5, 1200/5, 1500/5, 1600/5, 2000/5 A
RCT-1102000/5, 2500/5, 3000/5, 4000/5, 5000/5 A

Window, burden and class

ModelPrimary / secondaryBusbar holeRated burdenClassRated voltage
RCT-3530/5 A to 300/5 Aφ 35 mm1.5 to 10 VA0.5 / 1.00.72 kV AC
RCT-58300/5 A to 1200/5 Aφ 58 mm2.5 to 15 VA0.5 / 1.00.72 kV AC
RCT-90800/5 A to 1600/5 Aφ 90 mm5 to 15 VA0.5 / 1.00.72 kV AC
RCT-1101000/5 A to 3000/5 Aφ 110 mm10 to 20 VA0.5 / 1.00.72 kV AC
RCT-1302000/5 A to 6000/5 Aφ 130 mm20 to 30 VA0.5 / 1.00.72 kV AC
FAQ

Questions Buyers Ask

Is RCT suitable for outdoor installation?

No. The series is specified for indoor use, with an ambient temperature of -5 °C to 40 °C. For outdoor duty use the FSCT waterproof split core range.

How is an RCT fixed?

With a mounting plate. The body is deliberately small and light so it can be plated onto the gear rather than needing a base.

What is the largest window?

RCT-130, at φ 130 mm, covering 2000/5 A to 6000/5 A.