QIANWEI® Current Transformer
  1. Home
  2. Products
  3. Moulded Case And Busbar CTs
  4. CA Current Transformer
CA Current Transformer
CA / CP series

CA Current Transformer

Ten specifications in a body that is physically smaller than comparable models for the same ratio. A clamshell terminal cover protects the secondary and the accessory set adds DIN rail mounting, from 5 A up to 3000 A.

  • Primary current30 A to 3000 A
  • Secondary current5 A, 1 A
  • Standard approvalVDE 0414, BS 7626, IEC 44-1
  • Maximum voltage0.72 / 3 kV
  • Frequency50 to 60 Hz
  • Rated load2.5 VA, 5 VA, 10 VA, 15 VA
  • Class0.5, 1.0
  • Short time thermal currentIth = 60 × Ih

Product Overview

The CA/CP series current transformer comprises ten specifications. It is compact, smaller than other models with the same current ratio of the transformer, and the clamshell style terminal cover protects the secondary terminal well. With the related accessories you can use DIN rail mounting, from 5 A up to 3000 A.

Current transformer principle is based on electromagnetic induction. The current transformer is composed of a closed core and windings. Its primary winding has very few turns and is connected in series with the line in which current is to be measured; the secondary has more turns and is cascaded into measuring instruments and protection circuits. In service the secondary loop is always closed, so the impedance of the instruments and protection coils in series with it is small.

Application Scenarios

  • Current measurement, monitoring and protection for electrical wiring and equipment
  • Current and power measurement for electric motors, lighting, air compressors, heating and ventilation systems, air conditioning equipment and automation control systems
  • Current, power and energy monitoring devices
  • Relay protection devices

Technical Features

  • Ten frame specifications in one family
  • Physically smaller than comparable models at the same ratio
  • Clamshell style terminal cover protecting the secondary terminals
  • DIN rail mounting available with the related accessories

Specifications

Frame ladder

ModelPrimary currentSecondaryRated loadClass
CA/CP-62/2030 A to 200 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0
CA/CP-62/3030 A to 400 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0
CA/CP-62/4060 A to 600 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0
CA/CP-74/4060 A to 600 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0
CA/CP-74/50200 A to 1000 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0
CA/CP-86/60400 A to 1500 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0
CA/CP-104/80600 A to 2000 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0
CA/CP-140/100800 A to 3000 A5 A, 1 A2.5 / 5 / 10 / 15 VA0.5, 1.0

All frames: maximum voltage 0.72/3 kV, 50-60 Hz, VDE 0414 / BS 7626 / IEC 44-1, Ith = 60 × Ih, rated security FS < 5.

Real Product Photography

CA Current Transformer Gallery

CA/CP-62/20 current transformer, 30 A to 200 A primary
CA/CP-62/20 current transformer, 30 A to 200 A primary
CA/CP-62/30 current transformer, 30 A to 400 A primary
CA/CP-62/30 current transformer, 30 A to 400 A primary
CA/CP-62/40 current transformer, 60 A to 600 A primary
CA/CP-62/40 current transformer, 60 A to 600 A primary
CA/CP-74/40 current transformer, 60 A to 600 A primary
CA/CP-74/40 current transformer, 60 A to 600 A primary
CA/CP-74/50 current transformer, 200 A to 1000 A primary
CA/CP-74/50 current transformer, 200 A to 1000 A primary
CA/CP-86/60 current transformer, 400 A to 1500 A primary
CA/CP-86/60 current transformer, 400 A to 1500 A primary
CA/CP-104/80 current transformer, 600 A to 2000 A primary
CA/CP-104/80 current transformer, 600 A to 2000 A primary
CA/CP-140/100 current transformer, 800 A to 3000 A primary
CA/CP-140/100 current transformer, 800 A to 3000 A primary
FAQ

Questions Buyers Ask

How do I calculate the burden of a current transformer?

Add the VA of every device in the secondary loop plus the loss in the secondary cable, then pick the next standard burden above that total. The CA series is offered at 2.5, 5, 10 and 15 VA. If the connected burden is far below the rated burden the CT still works; if it is above, the ratio and phase error leave the declared class.

What is the difference between the CA and the MES series?

They share the electrical ladder and the same standards. The CA body is the more compact of the two for a given ratio and uses a clamshell terminal cover; the MES body carries three built in fixing methods and a hinged cover. Panel space usually decides.

Is a 1 A secondary available?

Yes. Every CA frame is available with a 5 A or a 1 A secondary. A 1 A secondary is normally chosen where the run between the CT and the instrument is long.

Are free samples available?

The client's catalogue offers samples on the popular frames. Message an engineer on WhatsApp with the ratio, class and burden you need and we will confirm.

Related Products

Compare With These Frames

Get CA Current Transformer Quoted Today

Send the ratio, accuracy class, burden and conductor size. An engineer confirms the frame and the price.

WhatsAppEmail