- Home
- Products
- Moulded Case And Busbar CTs
- MSQ Current Transformer
MSQ Current Transformer
The Asian volume model. Seven window sizes from 30 mm to 125 mm cover 5/5 A right through to 6000/5 A, in AC circuits rated below 720 V, and the same body is used to complete mine transformer sets.
- Rated input1 A to 5000 A (frames to 6000 A)
- Rated output1 A, 5 A
- Measuring range5 %In to 120 %In
- Accuracy class0.5 / 1.0
- Ratio voltage0.72 kV AC
- Dielectric strength3.0 kV / 1 mA / 1 min
- CasePC / UL94-V0
- CoreSilicon steel
Product Overview
The MSQ range of current transformers can be applied to test, control, display and record the running of electrical equipment, and to protect equipment against damage, in AC circuits with a rated voltage value below 720 V and a frequency of 50-60 Hz. The product can also be applied to form a complete set of mine transformer.
Application Scenarios
- Current measurement, monitoring and protection for electrical wiring and equipment
- Current and power measurement for electric motors, lighting, air compressors, heating and ventilation systems, air conditioning equipment and automation control systems
- Current, power and energy monitoring devices
- Relay protection devices
Technical Features
- Safe, easy to install and portable
- Wide inner window allowing clamping of big cables or busbars
- Wide range of sizes to accommodate all existing installations
Specifications
Technical data
| Electrical parameter | Value | Mechanical parameter | Value |
|---|---|---|---|
| Frequency | 50 / 60 Hz | Case | PC / UL94-V0 |
| Rated input | 1 A to 5000 A | Bobbin | PBT |
| Measuring range | 5 %In to 120 %In | Core | Silicon steel |
| Rated output | 1 A, 5 A | Construction | Screw |
| Ratio voltage | 0.72 kV AC | Operating temperature | -25 °C to +75 °C |
| Dielectric strength | 3.0 kV / 1 mA / 1 min | Operating humidity | ≤ 85 % |
| Insulation resistance | DC 500 V / 100 MΩ min | Output connection | Terminal |
Frame ladder
| Model | Primary / secondary | Busbar hole dimension | Rated burden | Class | Rated voltage |
|---|---|---|---|---|---|
| MSQ-30B | 5/5 A to 300/5 A | busbar | 5 to 7.5 VA | 0.5 / 1.0 | 0.72 kV AC |
| MSQ-30 | 30/5 A to 300/5 A | φ 30 mm | 2.5 to 10 VA | 0.5 / 1.0 | 0.72 kV AC |
| MSQ-40 | 100/5 A to 500/5 A | φ 40 mm | 2.5 to 10 VA | 0.5 / 1.0 | 0.72 kV AC |
| MSQ-60 | 250/5 A to 1600/5 A | φ 60 mm | 5 to 15 VA | 0.5 / 1.0 | 0.72 kV AC |
| MSQ-85 | 750/5 A to 2000/5 A | φ 85 mm | 5 to 15 VA | 0.5 / 1.0 | 0.72 kV AC |
| MSQ-100 | 800/5 A to 3000/5 A | φ 100 mm | 5 to 15 VA | 0.5 / 1.0 | 0.72 kV AC |
| MSQ-125 | 1000/5 A to 6000/5 A | φ 125 mm | 5 to 20 VA | 0.5 / 1.0 | 0.72 kV AC |
MSQ Current Transformer Gallery




Questions Buyers Ask
What is the largest ratio available?
MSQ-125 covers 1000/5 A up to 6000/5 A through a 125 mm window, which is the top of the range.
Can MSQ be used above 720 V?
No. The series is rated for AC circuits with a rated voltage below 720 V. Above that, move to the cast resin range.
Does MSQ suit mine transformer sets?
Yes, the product is stated as suitable to form a complete set of mine transformer.
What is the difference between MSQ-30 and MSQ-30B?
MSQ-30 has a 30 mm round window for cable; MSQ-30B is the busbar variant and starts at 5/5 A.
Compare With These Frames
MES Busbar Instrument Current Transformer
Primary current 5 A to 3000 A
Secondary current 5 A / 1 A
ABO Current Transformer
Primary current 5 A to 5000 A
Secondary current 5 A, 1 A, 0.5 A, 0.25 A, 0.1 A
Get MSQ Current Transformer Quoted Today
Send the ratio, accuracy class, burden and conductor size. An engineer confirms the frame and the price.