- Home
- Products
- Protection And Three Phase CTs
- FOX Current Transformer
FOX Current Transformer
Seventeen moulded case frames covering the whole ladder from a 1 A primary wound unit up to a 6000 A vertical busbar body, plus three triple CTs that mount straight onto a breaker.
- Primary range1 A to 6000 A across the family
- Terminal coversBuilt in sliding sealable covers
- Triple bodies25 mm, 35 mm and 45 mm centres
- ConstructionMoulded case, primary wound and window type
Product Overview
The FOX range is a moulded case family with built in sliding sealable terminal covers, published frame by frame. It covers primary wound units for very low primary currents, compact bodies for cable and busbar, vertical busbar bodies for high current risers, and triple bodies that allow installation directly on top of moulded case circuit breakers.
Application Scenarios
- Low voltage switchboards and risers
- Very low primary current metering
- Breaker mounted three phase metering
Technical Features
- Primary wound frames with M6 terminals for 1 A to 40 A primary
- Compact frames for cable and busbar from 50 A upwards
- Vertical busbar frames for high current risers
- Triple bodies for direct MCCB mounting
- Built in sliding sealable terminal covers
Specifications
Published frames
| Frame | Type | Primary range |
|---|---|---|
| FOX.SUM | Primary wound, M6 primary terminals | 1 A to 40 A |
| FOX140 | Compact, smallest body | 50 A to 300 A |
| FOX21 | Compact | 100 A to 600 A |
| FOX30.1 | Compact | 100 A to 800 A |
| FOX40.1 | Compact | 250 A to 1200 A |
| FOX50.1 | Compact | 400 A to 1600 A |
| FOX60.15 | Compact | 400 A to 2000 A |
| FOX75 | Compact | 400 A to 2000 A |
| FOX.WP | Compact | 400 A to 4000 A |
| FOX100.3 | Compact | 600 A to 4000 A |
| FOX105 | Vertical busbar | 800 A to 4000 A |
| FOX105.38 | Vertical busbar | 800 A to 5000 A |
| FOX127.38 | Vertical busbar | 3000 A to 6000 A |
| FOX60.3 | Triple, 25 mm centres, 75 mm overall | MCCB top mounting |
| FOX100.55 | Triple, 35 mm centres, 105 mm overall | MCCB top mounting |
| FOX127.54 | Triple, 45 mm centres, 140 mm overall | MCCB top mounting |
Questions Buyers Ask
What is a primary wound current transformer?
One where the primary is a winding inside the transformer rather than the conductor passing through a window. It is how you get a usable output at very low primary currents, which is why FOX.SUM starts at 1 A.
Which FOX frame mounts on a breaker?
The triple bodies: FOX60.3 on 25 mm centres, FOX100.55 on 35 mm centres and FOX127.54 on 45 mm centres.
Are the terminal covers sealable?
Yes, the range uses built in sliding sealable terminal covers.
Compare With These Frames
TAS Three Phase Current Transformer
System voltage 720 V, 50 to 60 Hz
Test voltage 3 kV for 1 minute
Get FOX Current Transformer Quoted Today
Send the ratio, accuracy class, burden and conductor size. An engineer confirms the frame and the price.