AMADA INSTRUMENT CO.,LIMITED — Nanjing China
Microscope Slide

C7 0.1MM Micrometer Microscope Delimit Cross Line Reticle

The C7 0.1MM Micrometer Microscope Delimit Cross Line Reticle is a calibration slide made of optical glass with a 19mm diameter.

Product Overview

The C7 0.1MM Micrometer Microscope Delimit Cross Line Reticle is a calibration slide made of optical glass with a 19mm diameter. It features a grid of 0.1mm x 0.1mm divisions across both X and Y axes, providing a 10mm measuring range in each direction. The cross-line reticle enables precise alignment and measurement during stage calibration, inspection or documentation tasks.

  • MaterialOptical Glass
  • Diameter19mm
  • Grid division0.1mm x 0.1mm
  • Measuring range X10mm
  • Measuring range Y10mm
  • Reticle typeDelimit Cross Line

Key Benefits

  • 0.1mm x 0.1mm grid divisions allow precise measurement of small features under the microscope
  • 10mm measuring range in both X and Y directions supports full stage calibration
  • Optical glass construction ensures flatness and minimal distortion for accurate readings
  • Cross-line reticle provides clear alignment reference for positioning samples or measuring gaps
  • Universal fit for standard microscope stages with 19mm diameter slides

Application Scenarios

  • Calibrating the stage movement of a stereo or biological microscope before inspection
  • Measuring the pitch of fine solder joints, traces or micro-features on a PCB
  • Verifying the accuracy of a microscope's stage encoder or motorized positioning system
  • Documenting the dimensions of a component during quality inspection or failure analysis
  • Teaching students how to use a reticle for measurement in a laboratory setting

Who It Is For

  • Electronics manufacturers performing PCB and SMD inspection
  • Quality control labs verifying microscope stage accuracy
  • University and school teaching laboratories for hands-on measurement training
  • Research labs requiring repeatable stage positioning and measurement
  • Microscopy technicians setting up or maintaining inspection systems

Problems It Solves

  • A microscope stage with no calibration reference makes it difficult to verify measurement accuracy
  • Uncalibrated stages lead to inconsistent results when measuring component dimensions
  • Lack of a visible grid forces operators to estimate distances, increasing inspection error
  • Non-flat or distorted slides introduce measurement errors due to optical distortion
  • No standard reticle makes it hard to compare measurements across different microscopes or shifts

Technical Features

  • Made from optical glass for flatness and minimal optical distortion
  • 19mm diameter slide fits standard microscope stage holders
  • 0.1mm x 0.1mm grid divisions across X and Y axes
  • Measuring range of 10mm in both X and Y directions
  • Delimit cross-line reticle for alignment and reference during measurement
  • Universal fit for most standard microscope stages

Specifications

MaterialOptical Glass
Diameter19mm
Grid division0.1mm x 0.1mm
Measuring range X10mm
Measuring range Y10mm
Reticle typeDelimit Cross Line
Package included1PC x micrometer

Specifications are taken from the AMADA product data for this item. Confirm critical dimensions with us in writing before ordering.

Customization Options

  • Available in standard 19mm diameter with 0.1mm grid
  • No options for alternative grid sizes or reticle types listed in source

Comparison With Other Options

Standard blank microscope slideA blank slide offers no measurement reference; the C7 reticle provides a calibrated grid for direct reading of dimensions
1mm grid calibration slideThe 0.1mm grid allows finer measurement resolution than a 1mm grid, suitable for SMD and micro-assembly work
Digital image-based measurement softwareThe physical reticle provides immediate visual reference without requiring software setup or calibration

Use Guide

  • Place the slide on the microscope stage and align the cross-line reticle with the field of view
  • Use the 0.1mm divisions to measure distances between features or verify stage movement
  • Verify the 10mm range by counting 100 divisions along either axis
  • Clean the surface with lens tissue before use to avoid dust or residue affecting visibility
  • Store in a dry, flat location to prevent warping or damage to the reticle
Read Next

Guides and Applications

Answers

Frequently Asked Questions

What is the grid size on the C7 reticle?

0.1mm x 0.1mm divisions across both X and Y axes.

What is the total measuring range?

10mm in both X and Y directions, based on 100 divisions of 0.1mm each.

Is the reticle visible under low magnification?

Yes, the cross-line reticle is visible at low magnifications such as 10X or 20X, depending on the microscope.

Can this slide be used with any microscope?

Yes, it fits standard microscope stages with a 19mm diameter opening.

Does the reticle require cleaning?

Yes, clean the surface with a soft lens cloth before use to maintain clarity.

Is the slide reusable?

Yes, the optical glass construction allows repeated use with proper handling and cleaning.

Request A Price On The C7 0.1MM Micrometer Microscope Delimit Cross Line Reticle

Send quantity, destination and the application. We will confirm the configuration, the price and the lead time.