Drinking
Drinking Bowl
Robust drinker bowl with a float valve, so water is there when the animal wants it and nowhere else.
Drinking Systems
Diaphragm water control valve that holds the right pressure to bowls and nipple lines, all day and every day.
Almost every drinker fault traced back on a farm turns out to be a pressure fault. Too high and bite valves drip and floors go wet; too low and the animals at the end of the line do not get what they need. A diaphragm regulator holds a set outlet pressure regardless of what the mains is doing.
The valve is built to be serviced in place — the diaphragm is the wearing part and it is designed to be changed without cutting the line.

Key benefits
A diaphragm regulator holds the outlet setting through mains fluctuation.
Most drip and wet-floor problems in a room are over-pressure problems.
The diaphragm can be replaced without cutting the pipework.
Bowls, cups and nipples all last longer on a regulated supply.
Regulating the supply removes the cause instead of adjusting each drinker.
A regulated supply evens out the pressure along the run.
The wearing part is designed to be changed in place.
One-factory supply
Flooring, penning, feeding, water and climate are made on the same site, so a room can be specified and shipped as one order.
See the turnkey packageSpecifications
Figures below are taken from the JGM product catalogue. Anything we cannot source from it is marked TBC and confirmed with your quotation rather than estimated.
| Item | Specification |
|---|---|
| Type | Diaphragm water control valve |
| Function | Regulates outlet pressure to the drinker line |
| Service | Diaphragm replaceable in place |
| Stage | All stages |
| Connection and pressure range | TBC confirm your line size and supply pressure with the enquiry |
| Packing | Quantity |
|---|---|
| Method | Boxed |
| Notes | Carton size and container quantity confirmed with the quotation |
Ask for the full size chart and carton-loading data for your order.
Moulded and machined components, assembled in-house. The Water Control Valve is assembled from moulded and machined components on our own line. Moulded bodies come off the same presses as the rest of the range; stainless and metal parts are sourced to specification and fitted with the fasteners the assembly drawing calls for, so a replacement part years later still fits.
Comparison
| Alternative | When to choose it instead |
|---|---|
| Drinking Bowl | Float bowls downstream of a regulated supply refill consistently. |
| Drinking Cup | Bite cups seal correctly only on a regulated line. |
| Piglet Drinking Cup | A separately regulated piglet line gives the best control for creep drinkers. |
Use guide
Fit one regulator per room or per drinker line rather than one for the whole house.
Set the outlet pressure to the drinker manufacturer's figure, then check the last drinker on the run.
Record the setting on the valve so it can be restored after service.
Keep a spare diaphragm on the shelf — it is the part that wears.
Answers
Set it to the figure for the drinkers you are feeding, then verify flow at the far end of the line. Send your drinker type with the enquiry and we will advise.
Confirm your line size with the enquiry — connection details are marked TBC here rather than assuming your pipework.
It is better to regulate per room or per line, because rooms at different heights and lengths need different settings.
The diaphragm. It is replaceable in place, and keeping a spare avoids a room without water.
Related products
Drinking
Robust drinker bowl with a float valve, so water is there when the animal wants it and nowhere else.
Drinking
Bite-action drinking cup that delivers water only while the animal is drinking, and stays clean between.
Drinking
Low-flow piglet cup sized for creep and nursery pens, with a transparent bowl so intake can be seen.
Partitions
Integrated farrowing and weaner penning, engineered around the flooring and feeders that go in the same room.
Related reading
Troubleshooting ArticleWet pens, dripping drinkers and animals at the end of a line that never get enough: three symptoms, usually one cause.
Design GuideDisinfectant only works on a surface it can reach. Most biosecurity failures are surface-design failures, decided when the equipment was specified.
Talk to an engineer
Tell us the room size, the animal stage and the capacity you are aiming at. Our engineers reply with a layout, an equipment list and a quotation.