AMADA INSTRUMENT CO.,LIMITED — Nanjing China
Upright Metallurgical Microscope

XUM300 Upright Metallurgical Microscope

The XUM300 is an upright metallurgical microscope with a trinocular head, vertical illumination, and a quintuple nosepiece.

Product Overview

The XUM300 is an upright metallurgical microscope with a trinocular head, vertical illumination, and a quintuple nosepiece. It uses plan achromatic objectives with long working distance and no cover glass, designed for inspecting polished metal surfaces, semiconductor wafers, and other flat, reflective samples. The standard configuration includes a 6V 20W halogen lamp with adjustable brightness, field and aperture diaphragms, and a polarizer with color filters. The three-layer mechanical stage supports large samples with a 154mmX154mm travel range.

  • HeadTrinocular, 30° inclination
  • EyepieceWF10X (Φ18mm) standard, WF16X (Φ11mm) optional
  • ObjectivePL 5X/0.12, PL L10X/0.25, PL L20X/0.40, PL L40X/0.60, PL L50X/0.70, PL L60X/0.75 (Spring), PL L80X/0.80, PL L100X/0.85 (Spring), PL 100X/1.25 (Spring, oil) optional
  • Working distanceLong working distance, no cover glass required
  • IlluminationVertical, 6V 20W halogen lamp, adjustable brightness
  • DiaphragmsField diaphragm, aperture diaphragm, polarizer

Key Benefits

  • Trinocular head with 30-degree inclination allows simultaneous observation and camera capture
  • Long working distance objectives (no cover glass) prevent contact with polished metal surfaces
  • Vertical illumination with adjustable brightness and diaphragms improves contrast on reflective samples
  • Quintuple nosepiece with frontward ball bearing locating ensures stable objective switching
  • Three-layer mechanical stage provides 154mmX154mm travel for large or irregularly shaped samples

Application Scenarios

  • Inspection of polished metal cross-sections for grain structure and defects
  • Quality control of semiconductor wafers and thin-film layers
  • Failure analysis of machined or heat-treated metal parts
  • Documentation of microstructure images with a camera attached to the trinocular head
  • Teaching metallurgy or materials science using a shared image on a monitor

Who It Is For

  • Metallurgy and materials testing labs in foundries and heat-treatment facilities
  • Semiconductor and microelectronics quality inspection lines
  • University and technical college materials science teaching labs
  • Research labs studying metallography and surface morphology
  • Precision manufacturing quality departments inspecting machined components

Problems It Solves

  • Standard microscopes with horizontal illumination cannot resolve reflective metal surfaces properly
  • Short working distance objectives risk scratching polished metal samples during focus adjustment
  • Lack of a trinocular head forces the operator to choose between direct observation and image capture
  • Fixed stage size limits the inspection of large or irregularly shaped metal parts
  • No diaphragms or polarizer in the illumination path reduces contrast on anisotropic or textured surfaces

Technical Features

  • Plan achromatic objectives with long working distance, no cover glass required
  • Vertical illumination with 6V 20W halogen lamp and adjustable brightness
  • Field diaphragm, aperture diaphragm, and polarizer with Y, B, G filters and frosted filter
  • Quintuple nosepiece with frontward ball bearing inner locating for precise objective alignment
  • Three-layer mechanical stage with 154mmX154mm travel range and 250mmX230mm size
  • Trinocular head with 30-degree inclination for ergonomic viewing and camera integration
  • Interchangeable eyepieces for different field of view and magnification needs
  • CCD adapter options for camera integration with magnification factors from 0.4X to 1X

Specifications

HeadTrinocular, 30° inclination
EyepieceWF10X (Φ18mm) standard, WF16X (Φ11mm) optional
ObjectivePL 5X/0.12, PL L10X/0.25, PL L20X/0.40, PL L40X/0.60, PL L50X/0.70, PL L60X/0.75 (Spring), PL L80X/0.80, PL L100X/0.85 (Spring), PL 100X/1.25 (Spring, oil) optional
Working distanceLong working distance, no cover glass required
IlluminationVertical, 6V 20W halogen lamp, adjustable brightness
DiaphragmsField diaphragm, aperture diaphragm, polarizer
FiltersY, B, G color filters, frosted filter
NosepieceQuintuple, frontward ball bearing inner locating
StageThree-layer mechanical, 250mmX230mm size, 154mmX154mm travel range
CCD Adapter0.4X, 0.5X, 1X, 0.5X with 0.1mm/Div division optional
Standard Configurationindicates standard, indicates optional accessory

Specifications are taken from the AMADA product data for this item. Confirm critical dimensions with us in writing before ordering.

Customization Options

  • Choose between WF10X and WF16X eyepieces for different field of view
  • Select optional objectives including PL 100X/1.25 (oil) and PL L60X/0.75 (spring) for higher magnification
  • Add CCD adapter options for camera integration with 0.4X to 1X magnification
  • Upgrade to larger 280mmX270mm stage with 204mmX204mm travel range
  • Order trinocular head with or without analyzer and field diaphragm for polarized light use

Comparison With Other Options

XUM300 without trinocular headSame optics and stage, but the trinocular version allows simultaneous observation and camera capture without switching heads.
XUM300 with horizontal illuminationVertical illumination is essential for reflective metal samples; horizontal illumination would not provide adequate contrast.
XUM300 with fixed stageThe three-layer mechanical stage provides larger travel range and better sample positioning than a fixed stage.

Use Guide

  • Adjust the interpupillary distance before focusing to ensure a single merged image
  • Start with the lowest magnification objective to locate the area of interest before switching to higher magnifications
  • Use the field and aperture diaphragms to optimize contrast and reduce glare on reflective surfaces
  • For oil immersion, use the PL 100X/1.25 objective with immersion oil and clean the lens after use
  • Connect the CCD adapter to a camera via the trinocular port; select the appropriate magnification factor for the sensor size
Answers

Frequently Asked Questions

What is the working distance of the objectives?

All objectives have long working distance and do not require a cover glass. The exact distance varies by objective but is designed to prevent contact with polished samples.

Can I use oil immersion with this microscope?

Yes, the PL 100X/1.25 objective is designed for oil immersion and requires immersion oil for proper use.

Does the trinocular head support camera attachment?

Yes, the trinocular head includes a port for a CCD adapter to connect a digital camera.

What stage size is standard?

The standard stage is 250mmX230mm with a 154mmX154mm travel range. A larger 280mmX270mm stage with 204mmX204mm travel is available as an option.

Can I use polarized light?

Yes, the microscope includes a polarizer with Y, B, G filters and a frosted filter for polarized light observation.

Request A Price On The XUM300 Upright Metallurgical Microscope

Send quantity, destination and the application. We will confirm the configuration, the price and the lead time.