ANCHOR WELD (WUHAN) TECHNOLOGY CO., LTD — welding consumables for export [email protected]+86 13387610573

AK-ER70S-6 Gas Shielded Carbon Steel Welding Wire for High-Speed Fabrication.

A copper-coated solid wire for carbon and alloy steel welding with stable arc, low spatter, and excellent mechanical properties, suitable for high-speed applications on sheet plates and pipelines.

Welding Wire

Product Overview

AK-ER70S-6 is a gas shielded solid welding wire for manual and automated welding of carbon and alloy steel structures with tensile strength up to 500 MPa. It is designed for high-speed welding of sheet plates and pipelines, where consistent performance and clean weld appearance are required.

The wire features a copper coating that improves conductivity and reduces spatter during welding. Its chemical composition ensures low sensitivity to porosity and delivers high mechanical performance in the deposited weld metal. AKWELD supplies AK-ER70S-6 to the EN ISO 14341-A: G 42 3 C M G3Si1, AWS A5.18 ER70S-6, and GB/T 8110 ER70S-6 classifications.

Application: Used for carbon steel and alloy steel with 500MPa tensile strength structures welding, and high speed welding of sheet plates and pipelines.

Key Benefits

Stable Arc and Low Spatter.

The wire provides a stable arc across the recommended current range, minimizing spatter and reducing the need for post-weld cleaning.

Excellent Bead Appearance

The weld bead produced has a smooth, uniform profile, which reduces the need for grinding or finishing before painting or inspection.

High Mechanical Performance

The deposited metal achieves tensile strength of at least 500 MPa, yield stress of at least 420 MPa, elongation of at least 22 percent, and impact energy of at least 27 J at minus 30 degrees C.

Low Porosity Sensitivity

The chemical composition minimizes the risk of porosity in the weld metal, even under less-than-ideal shielding gas conditions.

Where It Is Used

  • Welding of carbon steel and alloy steel structures with tensile strength up to 500 MPa.
  • High-speed welding of sheet plates in fabrication shops.
  • Pipeline welding in field and shop environments.
  • Automated and semi-automated welding processes requiring consistent performance.

Who It Is For

  • Welding consumable distributors supplying solid wires for structural and pipeline projects.
  • Steel fabricators working with sheet and plate materials requiring high-speed welding.
  • Pipeline contractors needing consistent wire performance across multiple weld passes.

Problems It Solves

  • Porosity in welds caused by inconsistent wire chemistry or poor shielding gas coverage.
  • High spatter and poor bead quality that increase post-weld cleaning time.
  • Inconsistent mechanical properties in the deposited metal due to variable filler metal composition.
  • Need to switch between multiple wire types for different joint thicknesses or welding speeds.

Specifications

Published by the factory for AK-ER70S-6. Values not shown are not published on the datasheet and are marked as such rather than estimated.

Classifications
StandardDesignation
Classification 1EN ISO 14341-A: G 42 3 C M G3Si1
Classification 2AWS A5.18 ER70S-6
Classification 3GB/T 8110 ER70S-6
Typical Chemical Composition (%)
ElementContent
C0.06-0.15
SI0.8-1.15
Mn1.4-1.85
S0.025
P0.025
Ni0.15
Cr0.15
Mo0.15
Cu0.50
Typical Mechanical Properties
PropertyValue
Tensile strength (MPa)≥500
Yield Stress (MPa)≥420
Elongation (%)≥22J
Impact values (J)≥27J/-30℃
Recommended Welding Parameters
DiameterCurrent range
0.8mmF/H-50-200A V/OH-50-140A
1.0mmF/H-80-250A V/OH-80-160
1.2mmF/H-100-360A V/OH-80-220A

Technical Features

  • Copper-coated solid wire for improved conductivity and reduced spatter.
  • Chemical composition: C 0.06-0.15%, Si 0.8-1.15%, Mn 1.4-1.85%, S 0.025%, P 0.025%, Ni 0.15%, Cr 0.15%, Mo 0.15%, Cu 0.50%
  • Deposited metal tensile strength at least 500 MPa, yield stress at least 420 MPa, elongation at least 22 percent.
  • Impact energy at least 27 J at minus 30 degrees C.
  • Supplied in 0.8 mm, 1.0 mm, and 1.2 mm diameters with published current ranges for each.

Use Guide

  • Select diameter based on material thickness and welding position: 0.8 mm for thin sections, 1.0 mm for medium, 1.2 mm for thicker plates.
  • Use the recommended current ranges: 0.8 mm – flat/horizontal 50-200 A, vertical/overhead 50-140 A; 1.0 mm – flat/horizontal 80-250 A, vertical/overhead 80-160 A; 1.2 mm – flat/horizontal 100-360 A, vertical/overhead 80-220 A.
  • Ensure shielding gas is clean and dry, and maintain proper gas flow rate to prevent porosity.
  • Keep the wire spool sealed when not in use to prevent moisture absorption and contamination.

How It Compares

AK-ER70S-6 and ER70S-2 both weld carbon steel with similar tensile strength, but ER70S-6 has higher silicon and manganese content, which improves weld metal toughness and reduces porosity. ER70S-2 is more sensitive to shielding gas impurities and may produce more spatter. For high-speed welding where weld quality and consistency are critical, AK-ER70S-6 offers better performance than standard ER70S-2.

AK-ER70S-6 Questions

What classifications does AK-ER70S-6 meet?
It is supplied to EN ISO 14341-A: G 42 3 C M G3Si1, AWS A5.18 ER70S-6, and GB/T 8110 ER70S-6.
What are the mechanical properties of the deposited metal?
Tensile strength is at least 500 MPa, yield stress at least 420 MPa, elongation at least 22 percent, and impact energy at least 27 J at minus 30 degrees C.
Which diameters and current ranges are available?
AKWELD supplies AK-ER70S-6 in 0.8 mm, 1.0 mm, and 1.2 mm. Recommended current ranges are: 0.8 mm – flat/horizontal 50-200 A, vertical/overhead 50-140 A; 1.0 mm – flat/horizontal 80-250 A, vertical/overhead 80-160 A; 1.2 mm – flat/horizontal 100-360 A, vertical/overhead 80-220 A.
Can I get a full catalogue and packing details before ordering?
Yes. Email the AKWELD sales team with the diameters and quantities you need and we will send the catalogue together with packing, marking and lead time details for your destination.
What packing is AK-ER70S-6 supplied in?
Packing and marking are set per order and destination. Send the quantity and the destination port with your enquiry and we will confirm the packing before you order.
Can we test AK-ER70S-6 before placing a production order?
Yes. Ask for a trial quantity so your welding engineer can run the grade on your own test plate and check the deposited metal against your procedure.

Request a Quotation for AK-ER70S-6

Send the diameter, the quantity and the destination port. Our technical team replies with packing, pricing and the data you need to qualify the grade.