learn about ER430
Learn about ER430 is a welding material specially used for welding 17% chromium ferritic stainless steel. used in some specific occasions.
ER430 welding wire is a specialized and performance-matched consumable for welding 17% chromium ferritic stainless steels, such as the 430 series (10Cr17). Its corrosion and wear resistance complements that of the base metal.learn about ER430.
Description: ER430 stainless steel welding wire is a welding material specially used for welding 17% chromium ferritic stainless steel. Due to its good corrosion resistance and wear resistance, it is used in some specific occasions.
Applications: Welding 10Cr17 (SUS430) and other materials, commonly used in wear-resistant and corrosion-resistant occasions, such as guardrails, golf heads, silencer system components, food and medical equipment components, etc.
For the main product details page, please click this link to view:
https://www.akweld.com/wp-content/uploads/2025/08/ER430.pdf
① MIG/MAG welding (DC reverse connection DC+): ● Shielding gas: It is recommended to use a mixture of Ar + (1~3)% O₂.
● Gas flow rate: 20-25 L/min recommended. ● Stickout length: Typically 15-25 mm. ● Reference welding current: – Φ0.8mm: 70-150 A – Φ1.0mm: 100-200 A – Φ1.2mm: 140-220 A – Φ1.6mm: 180-300 A (flat and horizontal); 180-250 A (vertical and overhead) ② TIG welding (AC or DC positive): ● Shielding gas: Use pure Ar. ● Gas Flow Rate: –For currents of 100-200A: 9-14 L/min –For currents of 200-300A: 14-18 L/min ● Reference Welding Current: –For 1.6mm Φ: 50-100 A –For 2.0mm Φ: 100-200 A –For 2.5mm Φ: 200-300 A –For 3.2mm Φ: 300-400 A
①: Pre-welding Cleaning: Thoroughly remove rust, moisture, oil, dust, and other impurities from the weld area. ②: Windbreaks: When welding outdoors, if wind speeds exceed 1.5 m/s (MIG) or exceed 1.0 m/s (TIG), windbreaks must be implemented to prevent the formation of gas holes. ③: Interpass Temperature Control: When welding ferritic stainless steel, controlling the interpass temperature (for example, no more than 150°C) helps prevent excessive grain growth, thereby maintaining good joint performance. ④: For TIG welding of critical components or single-sided welding with double-sided forming, it is recommended to apply argon shielding to the back of the weld to achieve better back-forming and prevent oxidation. ⑤: Heat Input Control: Carefully control the welding heat input. Excessive heat input may affect the mechanical properties and crack resistance of the weld metal. ⑥: Post-weld Heat Treatment: For certain demanding applications, post-weld heat treatment (such as annealing) may be required to optimize the corrosion resistance and toughness of the weld.
- Products AK Welding Wire
- AK Welding Electrodes
- AK Welding Rod
- AK Flux
Questions About This Article
Can AKWELD supply the consumables discussed in this article?
Can you advise on our specific joint?
Need the Consumables Behind This Article?
Tell us the grade or the base metal and we will confirm what we supply and send the data.