Fire Code Compliance

Matching the panel to the code clause, and supplying the test report that gets the submission approved.

The Problem

Why This Matters

Fire class is not a product feature to be chosen on preference. It is written into the local code by building height and use, and the wrong choice on a large elevation can mean re-cladding the building.

The Numbers

EN 13501-1A2-s1, d0 — report from an EU-notified body
GB 8624-2012A2 and B1 — National Center for Building Materials Testing
ASTM E84Class A — for the North American market
Standard PE coreB2, normal flammable — interior decoration only
A2 core weightRoughly 50% heavier than a PE core
Process

How We Run It

  • Send the code referenceProject location, building height, use, and the clause you are working to.
  • We specify the classA2 mineral core, B1 flame-retardant core, or standard core where no class is imposed.
  • Test reports issuedEN 13501-1, GB 8624-2012 and ASTM E84 reports supplied on request before the order.
  • Coating chosen separatelyCore and surface are independent, so the fire class does not restrict the colour.
  • Production and batch recordPanels produced with the core stated on the order and recorded per batch.
Reference Figures

Everything On One Sheet

EN 13501-1A2-s1, d0 — report from an EU-notified body
GB 8624-2012A2 and B1 — National Center for Building Materials Testing
ASTM E84Class A — for the North American market
Standard PE coreB2, normal flammable — interior decoration only
A2 core weightRoughly 50% heavier than a PE core
A2 core priceAbout 1.8–2.2× a standard PE-core panel per m²
High-rise patternAbove about 24 m, A2 is usually required
Mid-rise patternA2 or B1 depending on the local code
Range

Products For This Solution

Knowledge

Related Reading

FAQ

Fire Code Compliance FAQ

Which class does my project need?

The local code decides, using building height and use. As a pattern: high-rise above about 24 m needs A2; mid-rise commercial, hospitals and schools take A2 or B1; low-rise commercial and interior partitions are often acceptable in standard core.

Do you provide test certificates?

Yes — EN 13501-1 (A2-s1, d0), GB 8624-2012 (A2 and B1) and ASTM E84 (Class A). Certificates and recent test data are available on request.

Does a fire-rated core limit colour choice?

No. Core and coating are specified separately, so any standard or custom colour can be supplied on B1 or A2 core.

Is standard ACP fire rated?

Standard PE-core panel is classified B2, normal flammable, under GB 8624 and is suitable for interior decoration only.

Talk To The Factory

Talk To Us About Fire Code Compliance

Send what you have — a sample, a code clause or a schedule — and we will tell you what we need next.