Syringe filters, membrane filters, autosampler vials and closures, SPE columns, HPLC and GC accessories, labware, and industrial cartridges, capsules and housings.
Pharmaceutical QC, environmental testing, food and beverage, chemical analysis, life science and cosmetics laboratories, plus distributors and OEM filter brands.
Extractables on gradient baselines, low analyte recovery from binding membranes, blocked column frits, vial coring, and filters that burst before the sample is through.
In-house injection moulding, membrane die cutting and mould making. Part numbers printed on the housing so a reorder matches the qualified batch.

The 8-425 autosampler vial system is a standard ND8mm open-top screw glass vial designed for routine HPLC and GC…
View Details
The 9-425 autosampler vial is a standard ND9mm open-top screw vial designed for routine HPLC and GC sample storage…
View Details
Vials Racks are designed for stable storage, handling, and transportation of HPLC and GC sample vials in analytical…
View Details
The Crimper and Decrimper are manual tools made from stainless steel for securing and removing aluminium crimp seals…
View Details
Meltblow Cartridge Filters are standard industrial filtration cartridges designed for high dirt holding capacity and…
View Details
MK CF68 series capsule filters are ready-to-use units for critical small-volume flows of gases and liquids in…
View Details
The Soxhlet extractor is a laboratory apparatus used for continuous solvent extraction of solid samples. It operates…
View Details
Quantitative filter paper is designed for gravimetric analysis in chemical and environmental testing. Made from…
View Details
Cell Factory is a multi-layer cell culture vessel designed for scalable, high-density cell growth in…
View Details
Cell Culture Flasks are designed for adherent cell culture with a tissue culture-treated surface that supports cell…
View Details
RC Membrane Filters are made from regenerated cellulose with no added wetting agents and reinforced with nonwoven…
View Details
PVDF membrane filters are designed for high-performance liquid and gas filtration in analytical and biotech…
View Details
The SPE Column Guider is a precision alignment tool designed to ensure consistent positioning of solid-phase…
View Details
Mixed Mode Base SPE Columns offer a dual retention mechanism for selective extraction of drugs and metabolites from…
View Details
Reusable filter holders are designed for membrane filters ranging from 13 mm to 300 mm in diameter. These holders…
View Details
The Syringe Filter Guider is a precision alignment tool designed to ensure consistent and reliable syringe filter…
View DetailsA pharmaceutical QC laboratory depends on consistent, reproducible results across thousands of runs. Contamination, adsorption, and variability in…
An environmental testing laboratory processes complex matrices such as soil, water, and sludge, where trace analytes must be extracted and purified…
Food and beverage testing laboratories face challenges in extracting and cleaning up trace analytes from complex matrices like oils, beverages, and…
Chemical analysis laboratories performing extraction and purification tasks require reliable, repeatable equipment to maintain method integrity and…
Life science and biotechnology laboratories require consumables that support consistent cell growth, reliable sample recovery, and contamination…
A cosmetics and personal care laboratory must extract and quantify trace analytes from complex matrices such as emulsions, oils, and aqueous…
A multi-layer or solvent-bonded filter puts more contact material in the flow path. Single-layer membrane construction and injection-moulded sealing keep dissolution low.
A membrane that adsorbs the analyte lowers recovery and looks like a method fault. PES, RC and PVDF are the low-binding options in the range.
Moving from 13 mm to 25 mm raises filtration area from 1.09 to 2.98 cm2, and a coarser pre-filtration stage takes the load off the final filter.
Vials that do not match caps and filters that do not match syringes create their own failures. One catalogue covers collection, clarification, extraction and injection.
Private-label filtration and labware consumables built on Microlab's own moulding, membrane die-cutting and packing lines.
One supplier for the whole path from raw sample to injection vial: filtration, extraction, vials and labware.
Cartridges, capsules and housings for process liquid filtration outside the laboratory.
Roll membrane cut to disc size on the same line used for our own ranges.
Housings moulded in-house, with a mould making team for custom geometry.
Membrane sealed into the housing without solvent bonding in the flow path.
Membrane type, pore size and part number printed onto each housing.
Standard packing of 100 pieces per pack, with private-label packing on OEM orders.
Most filter selection mistakes happen because the analyst picks a pore size first and a membrane second. The membrane decides whether the…
A membrane that reacts with the solvent will degrade, shed extractables, or collapse, leading to baseline noise in HPLC or GC runs. Choose…
Regenerated cellulose (RC) membrane offers ultra-low non-specific binding and minimal extractables, making it ideal for trace-level…
Filtration and sample preparation consumables for analytical laboratories: 75 products across 8 categories covering syringe filters, membrane filters, autosampler vials and closures, SPE columns, HPLC and GC accessories, labware and industrial filtration cartridges, capsules and housings.
A manufacturer. Injection moulding, membrane die cutting and mould making are in-house, and the OEM division offers contract manufacturing and private-label packing on the same equipment.
Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system.
Yes. Email the product name and the application and trial quantities for method checking can be arranged.
Yes. The OEM division covers OEM plastic devices, OEM contract manufacturing, and membrane die-cut and packing, so private-label printing and packing can be arranged.
The factory is at 3F, Building 1, Tianxing Industrial Zone, Tiancheng Street, Yueqing City, Zhejiang Province 325609, China. There is also a Hong Kong office at Room 909B, 9/F, Two Grand Tower, 625 Nathan Road, KLN, Hong Kong.
Send the sample type, the solvent and the volume and we will come back with the membrane, pore size and diameter to use.