Syringe filters, chromatography vials, SPE and biotechnology products are produced according to the ISO 9001 standard system. [email protected] +86-15306778688
MK CF68 Series Capsule Fiter product photo 1
MK CF68 Series Capsule Fiter product photo 2MK CF68 Series Capsule Fiter product photo 3MK CF68 Series Capsule Fiter product photo 4MK CF68 Series Capsule Fiter product photo 5MK CF68 Series Capsule Fiter product photo 6
Industrial Filtration Products

MK CF68 Series Capsule Fiter

MK CF68 series capsule filters are ready-to-use units for critical small-volume flows of gases and liquids in industrial and laboratory settings. Available in multiple connection types, filter media, and pore sizes, they support a range of applications from ink and chemical solutions to biological and pure water filtration. Each unit undergoes a 100% pass integrity test and is double-sealed to prevent contamination.

  • Thermal welding ensures no adhesive in the flow path, reducing extractables and contamination risk
  • Wide range of filter media including PP, Nylon, PES, PTFE, PVDF for diverse chemical and biological compatibility
  • Multiple connection options: hose barb, NPT, quick coupling, and M10 lock for flexible integration
  • Effective filtration area exceeds 1200 cm² for 2.5" length, scaling to 4800 cm² for 10" length
Key Benefits

What This Product Gives You

  • Thermal welding ensures no adhesive in the flow path, reducing extractables and contamination risk
  • Wide range of filter media including PP, Nylon, PES, PTFE, PVDF for diverse chemical and biological compatibility
  • Multiple connection options: hose barb, NPT, quick coupling, and M10 lock for flexible integration
  • Effective filtration area exceeds 1200 cm² for 2.5" length, scaling to 4800 cm² for 10" length
  • Operates safely from pH 1 to 13 and up to 85℃ maximum temperature, with a maximum working pressure of 0.50 MPa at 21℃
  • Double-sealed packaging and clean room manufacturing ensure contamination-free delivery
  • Housing diameter: Φ68 mm
  • Filter lengths: 2.5", 5", 10"
  • Effective filtration area: ≥1200 cm² (2.5"), ≥2400 cm² (5"), ≥4800 cm² (10")
  • Operating pH range: 1 to 13
  • Working temperature: ≤65℃
  • Maximum working temperature: 85℃
  • Maximum working pressure: 0.50 MPa at 21℃
  • Forward maximum pressure difference: 0.42 MPa at 21℃
  • Thermal welded construction with no adhesive in flow path
  • 100% pass integrity test on every unit
  • Double sealed packaging to prevent contamination
Where It Is Used

Applications And Buyers

Application Scenarios

  • Filtration of ink in industrial printing systems where particle control is critical
  • Purification of chemical solutions requiring high compatibility with aggressive solvents
  • Sterile filtration of biological solutions and culture media in biotechnology processes
  • Gas filtration in compressed air systems for clean, dry output
  • Purification of pure water and cleaning fluids in pharmaceutical and food processing

Who It Is For

  • Industrial filtration engineers managing small-volume, high-purity liquid or gas streams
  • Biotech and pharmaceutical labs requiring reliable, pre-validated filters for culture media and drug solutions
  • Chemical processing plants handling corrosive or reactive liquids with strict contamination control
  • Laboratory distributors sourcing ready-to-use capsule filters with multiple media and connection options
  • OEMs integrating pre-assembled filters into larger systems without in-house assembly

Problems It Solves

  • Contamination from adhesive in solvent-bonded filters causing interference in sensitive analytical runs
  • Inconsistent performance due to poor sealing or material degradation under high temperature or pH extremes
  • Time lost in assembling filters from separate components, especially in high-throughput environments
  • Incompatibility with aggressive chemicals leading to housing or membrane failure
  • Lack of standardisation across multiple filter types when different media and connection styles are required
Data

Specifications

Housing DiameterΦ68 mm
Filter Length2.5", 5", 10"
Effective Filtration Area≥1200 cm² (2.5"), ≥2400 cm² (5"), ≥4800 cm² (10")
Operating pH1 to 13
Working Temperature≤65℃
Maximum Working Temperature85℃
Maximum Working Pressure0.50 MPa at 21℃
Forward Maximum Pressure Difference0.42 MPa at 21℃
Sealing TechnologyThermal welding
Integrity Test100% pass on every unit
PackagingDouble sealed to prevent contamination

Materials

  • Filter media: PP, Nylon, PES, PTFE, PVDF

Customization Options

  • Choice of filter media: PP, Nylon, PES, PTFE, PVDF
  • Pore sizes: 0.1, 0.22, 0.45, 0.65, 0.8, 1.0, 3.0, 5.0, 10.0, 100.0 micron
  • Multiple connection types: 1/8" hose barb, 1/4" hose barb, 3/8" hose barb, 1/2" hose barb, 1/8" NPT, 1/4" NPT, 1/2" NPT, 1/8" male quick coupling, 1/4" male quick coupling
  • Custom length options: 2.5", 5", 10"
  • OEM private-label printing and packaging available through the Microlab OEM division
How It Is Made

Manufacturing And Quality Control

Manufacturing Process

  • Thermal welding of housing and membrane
  • Assembly of connection fittings (hose barb, NPT, quick coupling, M10 lock)
  • Integration of selected filter media and pore size
  • 100% integrity testing after assembly
  • Double-sealed packaging in clean room environment

Quality Control

  • Visual inspection of housing and sealing before assembly
  • Integrity test performed on every unit to confirm no leaks
  • Verification of filter media and pore size against order specification
  • Check of connection type and length against order code
  • Final packaging inspection to ensure double-sealed integrity
Comparison

Compared With The Alternatives

Versus Solvent-bonded filters

Thermal welding eliminates adhesive in the flow path, reducing extractables and contamination risk, especially important in sensitive biological or analytical applications.

Versus Multi-piece filter assemblies

The ready-to-use capsule design reduces assembly time and human error, while maintaining consistent sealing and integrity.

Versus Standard filter cartridges

The CF68 series offers a wider range of connection types and media options in a single housing format, simplifying inventory and integration.

Versus Reusable filter housings

Single-use capsule filters eliminate carry-over risk and cleaning validation burden, ideal for sterile or high-purity processes.

Use Guide

How To Use It

  • Select filter media based on sample chemistry: PTFE and PVDF for aggressive solvents, PES and PP for aqueous solutions, Nylon for mixed matrices
  • Choose pore size according to particle size: 0.1-0.45 micron for sterile or fine particulate removal, 0.65-5.0 micron for general clarification
  • Match connection type to system fittings: hose barb, NPT, or quick coupling as required
  • Verify filter length (2.5", 5", 10") to match flow rate and volume requirements
  • Do not exceed 0.50 MPa at 21℃ or 85℃ maximum temperature; monitor pressure drop during use
  • Discard after single use to prevent contamination carry-over; store in sealed packaging until use
Photos

Product Gallery

Also In This Category

Related Products

Read Next

Related Industries And Guides

FAQ

Questions Buyers Ask

What filter media are available in the CF68 series?

Available media include PP, Nylon, PES, PTFE, and PVDF, covering a range of chemical and biological compatibility needs.

What are the available connection types?

Options include 1/8", 1/4", 3/8", and 1/2" hose barbs, 1/8", 1/4", and 1/2" NPT, and 1/8" and 1/4" male quick couplings.

What is the maximum operating pressure?

Maximum working pressure is 0.50 MPa at 21℃, with a forward maximum pressure difference of 0.42 MPa at 21℃.

Can I use this filter for biological solutions?

Yes. The CF68 series is suitable for biological solutions, culture media, and medicine liquids due to its chemical compatibility and clean construction.

Is the filter suitable for high-temperature applications?

Yes. The filter can withstand a maximum working temperature of 85℃, with a continuous operating limit of 65℃.

Do you offer private-label or OEM options?

Yes. The Microlab OEM division supports private-label printing, packaging, and custom assembly for filter brands and system integrators.

Get A Quote For MK CF68 Series Capsule Fiter

Tell us the membrane, pore size, diameter and quantity you need, or describe the sample and we will specify it.