XIM100 Inverted Metallurgical Microscope
The XIM100 is an inverted metallurgical microscope with a one-piece frame and a trinocular observation tube.

Product Overview
The XIM100 is an inverted metallurgical microscope with a one-piece frame and a trinocular observation tube. It supports 5X to 100X magnification with infinity-corrected long working distance objectives, a mechanical stage for precise specimen positioning, and a 12V100W halogen lamphouse for reflected light illumination. The 20/80 beam splitter allows simultaneous viewing and camera capture, and the high eye-point eyepieces reduce eye strain during extended use.
- Optical systemInfinity-corrected
- HeadTrinocular
- Interpupillary adjustment48~75mm / 52~75mm
- Inclination angle30°
- Beam splitter ratio20/80 / 100/0
- EyepieceWF10X/20mm, WF10X/22mm, WF10X/18mm reticule, WF10X/20mm reticule
Key Benefits
- One-piece frame ensures stability during long inspection sessions
- 20/80 beam splitter in trinocular tube enables real-time camera capture without losing the optical view
- Long working distance objectives (5X to 100X) allow inspection of thick or irregularly shaped metal samples
- Mechanical stage with 80mm x 50mm movement range supports precise positioning of specimens
- High eye-point eyepieces (up to 21mm) reduce eye strain during extended use
- Infinity-corrected optics with plan objectives deliver flat, high-contrast images across the field
Application Scenarios
- Inspection of metal surfaces, castings, and weld joints in foundry quality control
- Failure analysis of machined components and heat-treated parts
- Quality checks on metal coatings, plating, and surface finishes
- Microstructure evaluation of alloys and metallographic samples under reflected light
- Teaching metallurgy and materials science in university or vocational labs
Who It Is For
- Metallurgy and materials testing labs in manufacturing plants
- Foundry and heat-treatment quality departments
- University and technical school teaching labs in materials science
- Research labs analyzing metal fatigue, grain structure, and surface defects
- Precision engineering workshops inspecting machined metal parts
Problems It Solves
- A standard upright microscope cannot accommodate thick or bulky metal samples
- Fixed magnification or short working distance objectives limit access to deep or uneven surfaces
- Lack of a beam splitter forces users to choose between viewing and capturing images
- Poor eye relief in standard eyepieces causes discomfort during long inspection sessions
- Mechanical stage with limited movement range makes precise specimen positioning difficult
Technical Features
- One-piece frame construction from arm to base for rigidity and stability
- Trinocular observation tube with 20/80 beam splitter for simultaneous viewing and camera capture
- Diopter-adjustable binocular and trinocular tubes with 30° inclination for ergonomic viewing
- Infinity-corrected optical system with long working distance objectives for deep sample access
- Mechanical stage with 80mm x 50mm travel range and low-positioned X/Y coaxial controls
- 12V100W halogen lamphouse with 12V50W power supply for consistent reflected light illumination
- Interpupillary adjustment range of 48-75mm and 52-75mm depending on tube configuration
- High eye-point eyepieces (up to 21mm) for comfortable viewing with glasses
- Quintuple revolving nosepiece for quick objective switching
- Optional filters (blue, green, yellow) and polarizing kits for enhanced contrast in metallography
Specifications
| Optical system | Infinity-corrected |
|---|---|
| Head | Trinocular |
| Interpupillary adjustment | 48~75mm / 52~75mm |
| Inclination angle | 30° |
| Beam splitter ratio | 20/80 / 100/0 |
| Eyepiece | WF10X/20mm, WF10X/22mm, WF10X/18mm reticule, WF10X/20mm reticule |
| Objective magnification | 5X, 10X, 20X, 50X, 80X, 100X (Oil) |
| Objective type | Infinity Long WD Plan Objectives |
| Working distance | Long WD (specific values not provided) |
| Stage type | Mechanical Stage |
| Stage size | 180mm x 155mm |
| Stage movement range | 80mm x 50mm |
| Control type | Low-positioned X/Y coaxial knobs |
| Illumination | 12V100W Halogen Lamphouse |
| Power supply | 12V50W / 12V100W |
| Bulb type | Osram Halogen (12V50W / 12V100W) |
| Filter diameter | φ32mm |
| Filter types | Blue, Green, Yellow |
| Polarizing kits | Analyzer Kits, Polarizer Kits |
| C-Mount adapter | 0.5X, 0.25X, 1X |
| Micrometer | 1/100mm |
| Allen screw drivers | Φ1.5mm, Φ2mm, Φ3mm |
| Power cord | Included |
| Fuse | 250V/3.15A Φ5X20 |
| Dust cover | Included |
Specifications are taken from the AMADA product data for this item. Confirm critical dimensions with us in writing before ordering.
Customization Options
- Choose between binocular and trinocular tube configurations with 20/80 or 100/0 beam splitter
- Select from multiple eyepiece types: WF10X/20mm, WF10X/22mm, reticule versions
- Add optional filters (blue, green, yellow) for contrast enhancement
- Install polarizing kits for stress and crystallographic analysis
- Use C-mount adapters (0.5X, 0.25X, 1X) for camera integration
- Upgrade to 100X objective with oil immersion for high-resolution surface detail
Comparison With Other Options
| Standard upright metallurgical microscope | The inverted design allows inspection of thick or bulky metal samples without obstruction from the stage, and the long working distance objectives provide access to deep or irregular surfaces. |
|---|---|
| Microscope without a beam splitter | The 20/80 trinocular tube allows simultaneous viewing and camera capture; a standard trinocular without beam splitting requires switching between modes. |
| Fixed magnification stand | The XIM100 supports multiple objectives (5X to 100X) and interchangeable eyepieces, so magnification can be adjusted without changing the entire stand. |
Use Guide
- Adjust the interpupillary distance to match your eye spacing before focusing to avoid eye strain
- Use the 100X objective with immersion oil for maximum resolution on polished metal surfaces
- Position the specimen on the mechanical stage and use the X/Y knobs to center it before switching objectives
- Use the 20/80 beam splitter to connect a camera while maintaining a clear view through the eyepieces
- Insert the appropriate filter (blue, green, yellow) to enhance contrast based on the sample type
- Clean the objective lenses and specimen surface before use to avoid artifacts in the image
More From Inverted Metallurgical Microscope

XIM900 Inverted Metallurgical Microscope
View Details
XIM800 Inverted Metallurgical Microscope
View Details
XIM700 Inverted Metallurgical Microscope
View Details
XIM600 Inverted Metallurgical Microscope
View Details
ICX41M Inverted Metallurgical Microscope
View Details
XIM500 Inverted Metallurgical Microscope
View Details
XIM400 Inverted Metallurgical Microscope
View Details
XIM300 Inverted Metallurgical Microscope
View DetailsGuides and Applications
Frequently Asked Questions
What is the working distance for the 100X objective?
The 100X objective is designed for oil immersion and has a short working distance; specific values are not provided in the source text.
Can I use this microscope for oil immersion?
Yes. The 100X objective is specified as (Oil), so it is designed for use with immersion oil.
Does the trinocular tube support camera capture?
Yes. The trinocular tube has a 20/80 beam splitter that allows light to pass to both the eyepieces and a camera simultaneously.
What power supply is required?
The microscope requires a 12V50W or 12V100W power supply, depending on the lamphouse used.
Can I use a camera with this microscope?
Yes. The C-mount adapters (0.5X, 0.25X, 1X) allow connection of digital cameras to the trinocular port.
Are the objectives interchangeable?
Yes. The quintuple revolving nosepiece allows quick switching between the 5X, 10X, 20X, 50X, 80X, and 100X objectives.
Request A Price On The XIM100 Inverted Metallurgical Microscope
Send quantity, destination and the application. We will confirm the configuration, the price and the lead time.