Heel guard, concrete cover, ditch, welded and press locked steel grating, made in Yantai since 2010 Mon-Fri 08:30-17:30 GMT+8 [email protected] +86 138-5358-4341
  1. Home
  2. Products
  3. Press Locked Grating
  4. Press Locked Grating 30x2 Stainless Steel
Close view of press locked steel grating showing the flush joint between bearing bar and cross bar
Press Locked Grating · Acid passivation

Press Locked Grating 30x2 Stainless Steel

Light stainless press locked panel with matched 30x2 bearing and cross bars, acid passivated, for hygienic floors and light-duty visible decks.

Bearing bar: 30 x 2 mmCross bar: 30 x 2 mmMaterial: stainless Steel
Press Locked Grating 30x2 Stainless Steel produced by ShengJingYe

Product Overview

The lightest press locked section in the range: 30 mm deep, 2 mm thick, with a cross bar of the same section, so again a square mesh but in a panel light enough to lift and hose down daily. It is specified where cleaning matters more than load, which describes most floor grating in food production, kitchens and laboratories. Because the joint is pressed rather than welded there is nowhere for product residue to sit in a weld fillet, and acid passivation after fabrication is what keeps the surface from picking up rust spots after the first few washdowns.

Key Benefits

  • Light enough to lift and clean daily without mechanical handling
  • No weld fillet for residue to collect in, which matters in hygiene audits
  • Square mesh in a light section, so the panel still looks finished
  • Acid passivated after fabrication, including cut ends and frames

At A Glance

Family
Press Locked Grating
Category
Press Locked Grating
Material
stainless Steel
Bearing bar
30 x 2 mm
Cross bar
30 x 2 mm
Surface treatment
Acid passivation
Product Images

What It Looks Like

Photographs of this product taken by the factory, lit and in production. Nothing here is a rendering of a product that does not exist yet.

Who It Is For

  • Food and beverage plant engineers
  • Hygiene and cleaning contractors specifying liftable floor panels
  • Laboratory and cleanroom fit-out contractors
  • Hospitality operators replacing corroded kitchen grating

Problems It Solves

  • Floor panels too heavy for cleaners to lift every shift
  • Residue trapped in weld fillets failing a hygiene inspection
  • Rust spots appearing on stainless panels that were never passivated
  • Galvanized panels that cannot survive a daily chemical washdown

Application Scenarios

  • Food production floor grating lifted for daily cleaning
  • Commercial kitchen and beverage line floors
  • Laboratory and cleanroom service areas
  • Light-duty walkways where appearance matters

Technical Features

  • Bearing bar 30 x 2 mm stainless steel
  • Cross bar 30 x 2 mm stainless steel, press locked
  • Square mesh geometry with no welded joints
  • Acid passivation after fabrication
  • Panel size set for single-person lifting
Specification

Published Specification

Every row below is reproduced from the manufacturer's published specification for this range. Rows shown in italics are figures the specification does not publish; those are confirmed in writing rather than estimated here.

Materialstainless Steel
Bearing bar30 x 2 mm
Cross bar30 x 2 mm
Surface treatmentAcid passivation
StructurePress Locked Grating
Panel sizeMade to your drawing
Place of productionYantai, Shandong Province, China
BrandShengJingYe
Minimum order quantitySmall batch accepted
Load classTBC, confirmed in writing against your loading
Lead timeConfirmed in writing per order, not published

Use Guide

  • Size panels to what one person can lift wet, not dry
  • Cap or round the banding where panels are handled every shift
  • Keep stainless tools and stainless brushes for these panels only
  • Rinse cleaning chemicals off rather than letting them dry on the surface
  • Inspect the frame seating when panels are back down after cleaning

Quality Control

  • Panel weight and size checked against the lifting requirement
  • Joint lock-up sampled across the run
  • Passivation applied after all fabrication, then inspected
  • Edges checked so cleaners are not handling sharp banding

Materials

  • Stainless steel bearing bar and cross bar, grade TBC
  • Passive layer restored by acid passivation after fabrication

Manufacturing Process

  • Drawing and 3D model
  • Cutting and stamping
  • Pressure welding or press locking
  • Framing and fabrication
  • Surface treatment
  • Inspection and packing

Certification Standards

Production follows TBC, the source specification publishes no certification marks. Certificates are sent per product on request rather than posted publicly, because the documents a shipment needs depend on the destination market.

Customisation Options

  • Panel size to the lift your cleaning team can manage
  • Rounded or capped edge detail for frequent handling
  • Frames and channel surrounds in matching stainless
  • Cut-outs for drains and equipment feet
Comparison

How It Compares With The Alternatives

A technical comparison against other ways of solving the same problem. Nothing here is a performance claim against a named competitor product.

Against a stock panel cut to fit on siteA stock panel trimmed on site loses its banding, its bar pitch at the edge and its coating at every cut. This one is drawn to the opening and coated after it is fabricated.
Against buying the panel and its frame separatelyPanel, banding, hooks, frame and handrail are fabricated and coated in the same plant and the same batch, which is what makes them fit each other.
Against another family in this rangeSee the Press Locked Grating page for what this family does that the others do not, and the related products below for the nearest alternatives.
Questions

Press Locked Grating 30x2 Stainless Steel Questions

How heavy is a panel?
It depends on the size, which is why panel size is set against your cleaning team’s lifting limit rather than to a standard sheet.
Will a 2 mm bar take a pallet truck?
No. This is a light-duty hygienic section. For wheeled traffic use a deeper section from the welded or concrete cover ranges.
Why does passivation matter here?
Daily chemical washdown attacks any spot where the passive layer was damaged by cutting or handling. Passivation restores it across the panel.
Can panels be made with capped edges?
Yes, edge capping is fabricated where panels are handled frequently.

Request Press Locked Grating 30x2 Stainless Steel

Send the finished size, the quantity, the mounting and the destination market. A quotation and the full specification come back by email.