Weighing Equipment For Scale Manufacturing And OEM
Scale builders do not buy products, they buy tolerances. What matters is whether the cell can carry the division count you sold, whether the head will pass the same approval, and whether the second batch matches the first. Everything in this catalogue is published with its full specification table for exactly that reason.
What Goes Wrong In This Industry
- A design finished before anyone checked whether the cell class supports the division count
- Second production batches with different output sensitivity that will not corner trim
- Datasheets that arrive a week after the engineering decision was needed
- Component and finished scale supply split across suppliers and containers
What Buyers Actually Need
- OIML R60 approved cells with published n max and v min
- Consistent output sensitivity and bridge resistance batch to batch
- A matching analogue indicator range
- Test weights to verify the finished build before dispatch
Products That Suit This Industry

L6D Single Point Load Cell
Smallest single point cell in the range, 2.5 kg to 50 kg on a 250 x 350 mm platform.
View specifications →
L6G Single Point Load Cell
Large deck single point cell, 50 kg to 600 kg on a 600 x 600 mm platform.
View specifications →
H8C Single Shear Beam Load Cell
Alloy steel single shear beam cell with OIML and NTEP approval, 0.5 t to 10 t.
View specifications →
HM9B Double Shear Beam Load Cell
Hermetically welded double shear beam cell for truck and railway scales, 10 t to 50 t.
View specifications →
HM14C Column Load Cell
Hermetically welded alloy steel column cell, 10 t to 50 t, with anti reversal self aligning design.
View specifications →
Stainless Steel Cylindrical Test Weight Set
Cylindrical calibration weight sets in stainless steel and chrome plated finishes, E2 to M2.
View specifications →Where Weighing Happens On Site
Bench scale build
A single point aluminium cell sized to the platform, with the maximum platform size published for each family so corner load behaviour is predictable.
Floor and platform scale build
Four shear beam cells and a summing box, with the same capacity and sensitivity across the set.
Weighbridge build
Column cells in C3 with a printable indicator and spares held for the installed base.
Final verification
Class F2 or M1 test weights used to verify each finished scale before it leaves the factory.
How We Specify For This Industry
Fix the division count
Decide the e value you have to certify, then pick the accuracy class whose n max covers it.
Check v min against your design
The minimum verification interval limits how small a division the finished scale can legally use.
Match the platform to the cell
Single point families publish a maximum platform size; exceeding it causes corner errors no trimming will remove.
Lock the bill of materials
Record cell family, capacity, sensitivity and cable length so repeat orders reproduce the same build.
Delivery Capability
- Component orders and finished scale orders combine into one shipment
- Cable lengths specified per capacity on each load cell family
- Delivery normally under 15 days
- Repeat orders quoted from the same specification sheet
Related Guides
How To Choose Load Cell Capacity And Accuracy Class
Capacity and accuracy class are the two numbers that decide whether a scale can be built and verified. Here is how to derive both before you commit to a design.
OIML R60 Accuracy Classes Explained For Scale Builders
Every load cell datasheet in this catalogue is a table of accuracy classes. This is how to read the columns and turn them into a decision.
Shear Beam S Type And Column Load Cells Compared
Four structures cover nearly every weighing build. Choosing the wrong one creates mounting problems that no amount of calibration will fix.
Single Point Load Cells And Platform Size Limits
Six aluminium single point families, six different platform limits. This is the number that decides the design, and it is published for every family.
Scale Manufacturing And OEM Questions
Can I order a trial quantity before committing?
Yes. Send the family, capacity and accuracy class you want to evaluate and we will quote a trial quantity, then hold the same specification for the production order.
Are output sensitivity and bridge resistance consistent between batches?
Each family publishes its output sensitivity, input resistance and output resistance with tolerances, and orders are placed against that specification. Quote the same family and capacity on repeat orders to keep a set corner trimmable.
Do you supply the summing box and cable?
Cable is fitted to the cells with length specified by capacity. Tell us what junction and summing hardware you need quoted alongside the cells.
Can you supply both components and finished scales on one order?
Yes, and it is the main reason builders work with us. Load cells, indicators, finished platforms and test weights ship together under one set of documents.
Specify Weighing For Scale Manufacturing And OEM
Send the weighing points on your site and the conditions around them. We will map the right products against each one.