Load Cells

HM9B Double Shear Beam Load Cell

Hermetically welded double shear beam cell for truck and railway scales, 10 t to 50 t.

Product Overview

The HM9B is the heavy beam cell used under truck scales and railway scales. Alloy steel, nickel plated and hermetically welded, it is built to sit outdoors for years under a deck that sees vehicles every day, and it is one of the two OIML R60 approved cell types we supply with weighbridge decks.

Key specifications
Capacity10 t to 50 t
Accuracy classesC1, C2, C3, A5M, B10M
ApprovalOIML R60 C3
Output sensitivity1.8 to 2.4 ±0.002 mV/V depending on class
Input resistance700 ±7 ohm to 775 ±5 ohm
Output resistance700 ±7 ohm
Excitation5 to 12 V DC recommended, 18 V DC maximum
Safe / ultimate overload150 % / 300 % of full scale

Category: Load Cells

Key Benefits

  • Hermetically welded and nickel plated for long outdoor service life
  • Capacities 10 t to 50 t per cell for heavy vehicle weighing
  • OIML R60 C3 approval for trade weighing installations
  • Safe and anti-explosion construction for hazardous areas

Problems It Solves

  • Cells corroding under a weighbridge deck after a few winters
  • Replacement cells that do not match the original set
  • Heavy capacity installations needing a documented accuracy class

Who It Is For

  • Weighbridge manufacturers and installers
  • Railway scale builders
  • Operators replacing cells under an existing truck scale

Application Scenarios

  • Four to eight cell weighbridge under a 12 m to 24 m deck
  • Railway wagon weighing installation
  • Replacing a failed cell in an installed truck scale
Technical

Technical Features

  • Capacities 10, 20, 25, 30, 40SE, 40 and 50 t
  • Alloy steel construction, nickel plated, hermetically welded
  • Oil-proof, waterproof and resistant to corrosive gas and media
  • Dual shear beam structure for truck and railway scale duty
  • Safe and anti-explosion product for atrocious weather and hazardous areas
Specifications

Full Specification Data

These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.

Manufacturer specification table 1
Capacityt10/20/25/30/40SE/40/50
AccuracyC1C2C3A5MB10M
ApprovalsOIML R60 C3
Maximum number of verification intervalsn max100020003000500010000
Minimum load cell verification intervalv minEmax/3000Emax/5000Emax/7500Emax /15000Emax /10000
Combined error(%FS)≤±0.050≤±0.030≤±0.020≤±0.026≤±0.050
Creep(%FS/30min)≤±0.038≤±0.024≤±0.016≤±0.017≤±0.040
Temperature effect on sensitivity(%FS/ 10℃ )≤±0.028≤±0.017≤±0.011≤±0.013≤±0.040
Temperature effect on zero(%FS/ 10℃ )≤±0.047≤±0.023≤±0.015≤±0.014≤±0.020
Output sensitivity(mv/v)2.0±0.0022.3±0.0022.4±0.0021.9±0.0021.8±0.002
Input resistance(Ω)700 ±7775 ±5750 ±7
Output resistance(Ω)700 ±7
Insulation resistance(MΩ)≥ 5000(50VDC)
Zero balance(%FS)1.5
Temperature, compensated(℃)-10~+40
Temperature,allowed(℃)-35~+65
Excitation, Recommended(V)5~12(DC)
Excitation,Max(V)18(DC)
Safe overload(%FS)150
Ultimate overload(%FS)300

Materials And Construction

  • Alloy steel, nickel plated
  • Hermetically welded sealing

Customisation Options

  • Accuracy class from C1 to C3
  • Capacity selected per deck design
  • Cable length to suit the cabin run

Use Guide

  • Order all cells for one weighbridge with the same capacity and output sensitivity so the set can be corner trimmed
  • Check the input resistance of the set against the indicator drive capability
  • Protect cable runs from rodents and standing water in the pit

Certification

  • OIML R60 C3
Comparison

How It Compares

Compared with alternatives in this catalogue
HM14C column cellBoth cover heavy capacity. The HM14C is a column cell with anti reversal and self aligning behaviour; the HM9B is a double shear beam, often the simpler retrofit under an existing deck.
H8C single shear beamThe H8C tops out at 10 t and suits platforms and hoppers. The HM9B starts at 10 t and is built for vehicle weighing.

Logistics And WarehousingScale Manufacturing And OEM

Questions Buyers Ask

HM9B Double Shear Beam Load Cell Questions

How many cells does a weighbridge need?

It depends on deck length and capacity, commonly four for short decks and six or eight for longer ones. Send the deck dimensions and we will confirm.

Can I replace a single failed cell?

Yes, provided the replacement matches capacity, output sensitivity and resistance. Ordering from the same family is what makes that possible years later.

Is the HM9B suitable for outdoor use?

Yes. It is hermetically welded and nickel plated specifically for atrocious weather and outdoor installations.

Get A Quotation For The HM9B Double Shear Beam Load Cell

Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.