The L6G carries a full 600 x 600 mm platform on one cell at capacities up to 600 kg, which is the practical ceiling for single point construction. It is offered with 350 ohm or 1000 ohm bridge resistance and in three accuracy grades, and carries OIML approval for trade builds.
| Capacity | 50 kg to 600 kg |
|---|---|
| Accuracy classes | C3D, C3, C3G |
| Approval | OIML R60 C3 |
| Maximum platform | 600 x 600 mm |
| Output sensitivity | 2.0 ±0.2 mV/V |
| Input resistance | 406 ±6 ohm or 1065 ±15 ohm |
| Output resistance | 350 ±3 ohm or 1000 ±10 ohm |
| Corner correction | 0.02 percent of load value per 100 mm |
Category: Load Cells
Key Benefits
- 600 x 600 mm platform on a single cell keeps four cell assemblies unnecessary
- Capacity to 600 kg for goods in and packing benches
- 350 ohm and 1000 ohm bridge options for mains or battery indicators
- OIML approval and three accuracy grades
Problems It Solves
- Four cell assemblies used where one cell would do
- Battery indicators struggling to drive low resistance bridges
- Large decks with unacceptable corner error
Who It Is For
- Platform scale manufacturers building larger benches
- Warehouse and dispatch equipment suppliers
- OEMs replacing four cell assemblies with a single point design
Application Scenarios
- 600 kg goods in bench with a 600 mm square deck
- Pallet corner weighing on a large bench
- Warehouse dispatch scale with a wide platform
Technical Features
- Capacities 50, 100, 150, 200, 250, 300, 500 and 600 kg
- Aluminium construction with parallel beam design
- Silicon adhesive sealed, surface anodised and anti-corrosion
- Integral installation with OIML approval
- Maximum platform size 600 x 600 mm
Full Specification Data
These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.
| Capacity | kg | 50/100/150/200/250/300/500/600 | ||
| Accuracy | C3D | C3 | C3G | |
| Approvals | OIML R60 C3 | |||
| Maximum numberof verification intervals | n max | 2500 | 3000 | 4000 |
| Minimum load cell verification interval | v min | Emax/5000 | Emax/7000 | Emax/11000 |
| Combined error | (%FS) | ≤±0.030 | ≤±0.020 | ≤±0.015 |
| Creep | (%FS/30min) | ≤±0.020 | ≤±0.0167 | ≤±0.0125 |
| Temperature effect on sensitivity | (%FS/10℃) | ≤±0.021 | ≤±0.0175 | ≤±0.0131 |
| Temperature effect on zero | (%FS/10℃) | ≤±0.028 | ≤±0.020 | ≤±0.0127 |
| Output sensitivity | (mv/v) | 2.0±0.2 | ||
| Input resistance | (Ω) | 406±6/1065±15 | ||
| Output resistance | (Ω) | 350±3/1000±10 | ||
| Insulation resistance | (MΩ) | ≥5000(50VDC) | ||
| Zero balance | (%FS) | 2 | ||
| Temperature,compensated | (℃) | -10~+40 | ||
| Temperature,operating | (℃) | -35~+65 | ||
| Excitation,Recommended | (V) | 5~12(DC) | ||
| Excitation,Max | (V) | 18(DC) | ||
| Safe overload | (%FS) | 150 | ||
| Ultimate overload | (%FS) | 300 | ||
| Corner correction | 0.02% load value/100mm | |||
Materials And Construction
- Anodised aluminium body
Customisation Options
- Accuracy class C3D, C3 or C3G
- 350 ohm or 1000 ohm bridge resistance
- Capacity from the published range
Use Guide
- Do not exceed 600 x 600 mm even at low capacity
- Use the 1000 ohm version where the indicator is battery powered
- Support the deck only on the cell so nothing else carries load
Certification
- OIML R60 C3
How It Compares
| L6T single point cell | Both allow 600 x 600 mm. The L6T extends to 1000 kg while the L6G tops out at 600 kg with the extra 1000 ohm bridge option. |
|---|---|
| H8C shear beam | Above 600 kg or 600 mm deck, four shear beam cells and a summing box become the better build. The L6G is the single cell alternative below that. |
Often Ordered With This Model

L6T Single Point Load Cell
Highest capacity single point cell in the range, up to 1000 kg on a 600 x 600 mm platform.
View specifications →
L6E Single Point Load Cell
Mid range single point cell, 50 kg to 300 kg on a 400 x 400 mm platform, OIML approved.
View specifications →
H8C Single Shear Beam Load Cell
Alloy steel single shear beam cell with OIML and NTEP approval, 0.5 t to 10 t.
View specifications →Single Point Load Cells And Platform Size Limits
Six aluminium single point families, six different platform limits. This is the number that decides the design, and it is published for every family.
Shear Beam S Type And Column Load Cells Compared
Four structures cover nearly every weighing build. Choosing the wrong one creates mounting problems that no amount of calibration will fix.
L6G Single Point Load Cell Questions
Can one L6G really carry a 600 mm platform?
Yes, that is the published maximum platform size for the family. Corner correction holds at 0.02 percent of load value per 100 mm within that limit.
Which bridge resistance should I choose?
350 ohm for standard indicators, 1000 ohm class where the indicator runs on battery and bridge current matters.
What is the highest capacity?
600 kg. Use the L6T for up to 1000 kg on the same deck size.