Load Cells

L6G Single Point Load Cell

Large deck single point cell, 50 kg to 600 kg on a 600 x 600 mm platform.

Product Overview

The L6G carries a full 600 x 600 mm platform on one cell at capacities up to 600 kg, which is the practical ceiling for single point construction. It is offered with 350 ohm or 1000 ohm bridge resistance and in three accuracy grades, and carries OIML approval for trade builds.

Key specifications
Capacity50 kg to 600 kg
Accuracy classesC3D, C3, C3G
ApprovalOIML R60 C3
Maximum platform600 x 600 mm
Output sensitivity2.0 ±0.2 mV/V
Input resistance406 ±6 ohm or 1065 ±15 ohm
Output resistance350 ±3 ohm or 1000 ±10 ohm
Corner correction0.02 percent of load value per 100 mm

Category: Load Cells

Key Benefits

  • 600 x 600 mm platform on a single cell keeps four cell assemblies unnecessary
  • Capacity to 600 kg for goods in and packing benches
  • 350 ohm and 1000 ohm bridge options for mains or battery indicators
  • OIML approval and three accuracy grades

Problems It Solves

  • Four cell assemblies used where one cell would do
  • Battery indicators struggling to drive low resistance bridges
  • Large decks with unacceptable corner error

Who It Is For

  • Platform scale manufacturers building larger benches
  • Warehouse and dispatch equipment suppliers
  • OEMs replacing four cell assemblies with a single point design

Application Scenarios

  • 600 kg goods in bench with a 600 mm square deck
  • Pallet corner weighing on a large bench
  • Warehouse dispatch scale with a wide platform
Technical

Technical Features

  • Capacities 50, 100, 150, 200, 250, 300, 500 and 600 kg
  • Aluminium construction with parallel beam design
  • Silicon adhesive sealed, surface anodised and anti-corrosion
  • Integral installation with OIML approval
  • Maximum platform size 600 x 600 mm
Specifications

Full Specification Data

These are the manufacturer figures for this model. Nothing has been rounded, averaged or filled in where the factory did not publish it.

Manufacturer specification table 1
Capacitykg50/100/150/200/250/300/500/600
AccuracyC3DC3C3G
ApprovalsOIML R60 C3
Maximum numberof verification intervalsn max250030004000
Minimum load cell verification intervalv minEmax/5000Emax/7000Emax/11000
Combined error(%FS)≤±0.030≤±0.020≤±0.015
Creep(%FS/30min)≤±0.020≤±0.0167≤±0.0125
Temperature effect on sensitivity(%FS/10℃)≤±0.021≤±0.0175≤±0.0131
Temperature effect on zero(%FS/10℃)≤±0.028≤±0.020≤±0.0127
Output sensitivity(mv/v)2.0±0.2
Input resistance(Ω)406±6/1065±15
Output resistance(Ω)350±3/1000±10
Insulation resistance(MΩ)≥5000(50VDC)
Zero balance(%FS)2
Temperature,compensated(℃)-10~+40
Temperature,operating(℃)-35~+65
Excitation,Recommended(V)5~12(DC)
Excitation,Max(V)18(DC)
Safe overload(%FS)150
Ultimate overload(%FS)300
Corner correction0.02% load value/100mm

Materials And Construction

  • Anodised aluminium body

Customisation Options

  • Accuracy class C3D, C3 or C3G
  • 350 ohm or 1000 ohm bridge resistance
  • Capacity from the published range

Use Guide

  • Do not exceed 600 x 600 mm even at low capacity
  • Use the 1000 ohm version where the indicator is battery powered
  • Support the deck only on the cell so nothing else carries load

Certification

  • OIML R60 C3
Comparison

How It Compares

Compared with alternatives in this catalogue
L6T single point cellBoth allow 600 x 600 mm. The L6T extends to 1000 kg while the L6G tops out at 600 kg with the extra 1000 ohm bridge option.
H8C shear beamAbove 600 kg or 600 mm deck, four shear beam cells and a summing box become the better build. The L6G is the single cell alternative below that.

Scale Manufacturing And OEMLogistics And Warehousing

Questions Buyers Ask

L6G Single Point Load Cell Questions

Can one L6G really carry a 600 mm platform?

Yes, that is the published maximum platform size for the family. Corner correction holds at 0.02 percent of load value per 100 mm within that limit.

Which bridge resistance should I choose?

350 ohm for standard indicators, 1000 ohm class where the indicator runs on battery and bridge current matters.

What is the highest capacity?

600 kg. Use the L6T for up to 1000 kg on the same deck size.

Get A Quotation For The L6G Single Point Load Cell

Tell us the capacity, accuracy class or division you need and the destination market. We will confirm availability, documentation and freight.